Due to the recent rapid expansion of scooter sharing companies, there has been a dramatic increase in the number of electric scooter (e-scooter) injuries. Our purpose was to conduct a systematic review to characterize the demographic characteristics, most common injuries, and management of patients injured from electric scooters. We searched PubMed, EMBASE, Scopus, and Web of Science databases using variations of the term “electric scooter”. We excluded studies conducted prior to 2015, studies with a population of less than 50, case reports, and studies not focused on electric scooters. Data were analyzed using Aims
Methods
Patient decision aids have previously demonstrated an improvement in the quality of the informed consent process. This study assessed the effectiveness of detailed written patient information, compared to standard verbal consent, in improving postoperative recall in adult orthopaedic trauma patients. This randomized controlled feasibility trial was conducted at two teaching hospitals within the South Eastern Sydney Local Health District. Adult patients (age ≥ 18 years) pending orthopaedic trauma surgery between March 2021 and September 2021 were recruited and randomized to detailed or standard methods of informed consent using a random sequence concealed in sealed, opaque envelopes. The detailed group received procedure-specific written information in addition to the standard verbal consent. The primary outcome was total recall, using a seven-point interview-administered recall questionnaire at 72 hours postoperatively. Points were awarded if the participant correctly recalled details of potential complications (maximum three points), implants used (maximum three points), and postoperative instructions (maximum one point). Secondary outcomes included the anxiety subscale of the Hospital and Anxiety Depression Scale (HADS-A) and visual analogue scale (VAS) for pain collected at 24 hours preoperatively and 72 hours postoperatively. Additionally, the Patient Satisfaction Questionnaire Short Form (PSQ-18) measured satisfaction at 72 hours postoperatively.Aims
Methods
Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK. A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages.Aims
Methods
The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis.Aims
Methods
The aim of this study was to perform the first population-based description of the epidemiological and health economic burden of fracture-related infection (FRI). This is a retrospective cohort study of operatively managed orthopaedic trauma patients from 1 January 2007 to 31 December 2016, performed in Queensland, Australia. Record linkage was used to develop a person-centric, population-based dataset incorporating routinely collected administrative, clinical, and health economic information. The FRI group consisted of patients with International Classification of Disease 10th Revision diagnosis codes for deep infection associated with an implanted device within two years following surgery, while all others were deemed not infected. Demographic and clinical variables, as well as healthcare utilization costs, were compared.Aims
Methods
Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and A2 hip fractures at a national level, and to define the cost implications of management decisions that run counter to national guidelines. We used the NHFD to identify all operations for fixation of trochanteric fractures in England and Wales between 1 January 2021 and 31 December 2021. A uniform price band from each of three hip fracture implant manufacturers was used to set cost implications alongside variation in implant use.Aims
Methods
Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.Aims
Methods
The purpose was to compare operative treatment with a volar plate and nonoperative treatment of displaced distal radius fractures in patients aged 65 years and over in a cost-effectiveness analysis. A cost-utility analysis was performed alongside a randomized controlled trial. A total of 50 patients were randomized to each group. We prospectively collected data on resource use during the first year post-fracture, and estimated costs of initial treatment, further operations, physiotherapy, home nursing, and production loss. Health-related quality of life was based on the Euro-QoL five-dimension, five-level (EQ-5D-5L) utility index, and quality-adjusted life-years (QALYs) were calculated.Aims
Methods
The aims of this network meta-analysis (NMA) were to examine nonunion rates and functional outcomes following various operative and nonoperative treatments for displaced mid-shaft clavicle fractures. Initial search strategy incorporated MEDLINE, PubMed, Embase, and the Cochrane Library for relevant randomized controlled trials (RCTs). Four treatment arms were created: nonoperative (NO); intramedullary nailing (IMN); reconstruction plating (RP); and compression/pre-contoured plating (CP). A Bayesian NMA was conducted to compare all treatment options for outcomes of nonunion, malunion, and function using the Disabilities of the Arm Shoulder and Hand (DASH) and Constant-Murley Shoulder Outcome scores.Aims
Methods
It is imperative to understand the risks of operating on urgent cases during the COVID-19 (SARS-Cov-2 virus) pandemic for clinical decision-making and medical resource planning. The primary aim was to determine the mortality risk and associated variables when operating on urgent cases during the COVID-19 pandemic. The secondary objective was to assess differences in the outcome of patients treated between sites treating COVID-19 and a separate surgical site. The primary outcome measure was 30-day mortality. Secondary measures included complications of surgery, COVID-19 infection, and length of stay. Multiple variables were assessed for their contribution to the 30-day mortality. In total, 433 patients were included with a mean age of 65 years; 45% were male, and 90% were Caucasian.Aims
Methods
Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).Aims
Methods
External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF). A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness.Objectives
Methods
The number of clinical negligence claims in the UK is constantly increasing. As a specialty, trauma and orthopaedic surgery has one of the highest numbers of negligence claims. A formal request was made to the NHSLA under the Freedom of Information Act in order to obtain all data related to claims against orthopaedic surgery. It was found that the number of claims, and percentage of successful claims, has been constantly increasing over this period, with compensation paid of over £349 million.* Errors in clinical management accounted for the highest number of closed claims (2933 claims), costing over £119 million.* The level of compensation paid out has a significant financial impact on the NHS. Reforms need to be made in order to tackle the high cost of legal fees generated by these claims, which further drain the limited resources available to the NHS.