Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Bone & Joint Research
Vol. 2, Issue 8 | Pages 140 - 148
1 Aug 2013
Gauthier L Dinh L Beaulé PE

Objectives. To quantify and compare peri-acetabular bone mineral density (BMD) between a monoblock acetabular component using a metal-on-metal (MoM) bearing and a modular titanium shell with a polyethylene (PE) insert. The secondary outcome was to measure patient-reported clinical function. Methods. A total of 50 patients (25 per group) were randomised to MoM or metal-on-polyethlene (MoP). There were 27 women (11 MoM) and 23 men (14 MoM) with a mean age of 61.6 years (47.7 to 73.2). Measurements of peri-prosthetic acetabular and contralateral hip (covariate) BMD were performed at baseline and at one and two years’ follow-up. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC), University of California, Los Angeles (UCLA) activity score, Harris hip score, and RAND-36 were also completed at these intervals. Results. At two years, only zone 1 showed a loss in BMD (-2.5%) in MoM group compared with a gain in the MoP group (+2.2%). Zone 2 showed loss in both groups (-2.2% for MoM; -3.9% for MoP) and zones 3 and 4 a gain in both groups (+0.1% for MoM; +3.3% for MoP). No other between-group differences were detected. When adjusting for BMD of the contralateral hip, no differences in BMD were observed. The only significant differences in functional scores at two years were higher UCLA activity (7.3 (. sd. 1.2) vs 6.1 (. sd. 1.5); p = 0.01) and RAND-36 physical function (82.1 (. sd. 13.0) vs 64.5 (. sd. 26.4); p = 0.02) for MoM bearings versus MoP. One revision was performed in the MoM group, for aseptic acetabular loosening at 11 months. Conclusions. When controlling for systemic BMD, there were no significant differences between MoM and MoP groups in peri-acetabular BMD. However, increasing reports of adverse tissue reactions with large head MoM THR have restricted the use of the monoblock acetabular component to resurfacing only


Bone & Joint 360
Vol. 4, Issue 2 | Pages 10 - 12
1 Apr 2015

The April 2015 Hip & Pelvis Roundup. 360 . looks at: Goal-directed fluid therapy in hip fracture; Liberal blood transfusion no benefit in the longer term; Repeated measures: increased accuracy or compounded errors?; Peri-acetabular osteotomy safer than perhaps thought?; Obesity and peri-acetabular osteotomy: poor bedfellows; Stress fracture in peri-acetabular osteotomy; Infection and tantalum implants; Highly crosslinked polyethylene really does work


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims. Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. Methods. A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed. Results. CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance. Conclusion. This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival. Cite this article: Bone Jt Open 2024;5(4):260–268


Bone & Joint 360
Vol. 2, Issue 1 | Pages 35 - 37
1 Feb 2013

The February 2013 Children’s orthopaedics Roundup. 360 . looks at: ABC treated with suction and curettage; peri-acetabular osteotomy; cast index; Perthes’ disease associated with accidental injury; brachial plexus birth palsy; MRI assessment of DDH; total meniscectomy; and paediatric septic arthritis


Bone & Joint 360
Vol. 4, Issue 4 | Pages 31 - 33
1 Aug 2015

The August 2015 Children’s orthopaedics Roundup360 looks at: Learning the Pavlik; MRI and patellar instability; Cerebral palsy and hip dysplasia; ‘Pick your poison’: elastic nailing under the spotlight; Club feet and surgery; Donor site morbidity in vascularised fibular grafting; Cartilage biochemistry with hip dysplasia; SUFE and hip decompression: a good option?


Bone & Joint 360
Vol. 2, Issue 2 | Pages 30 - 32
1 Apr 2013

The April 2013 Children’s orthopaedics Roundup360 looks at: improving stress distribution in dysplastic hips; the dangers of fashion; the natural history of supracondylar fractures; ankles that perform well as knees; intra-articular hip pathology at osteotomy; the safe removal of flexible nails; supracondylar fracture fixation; and talipes.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 14 - 16
1 Feb 2013

The February 2013 Hip & Pelvis Roundup360 looks at: amazing alumina; dual mobility; white cells and periprosthetic infection; cartilage and impingement surgery; acetabulum in combination; cementless ceramic prosthesis; metal-on-metal hips; and whether size matters in failure.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 29 - 31
1 Feb 2015

The February 2015 Children’s orthopaedics Roundup360 looks at: Hip dislocation in children with CTEV: two decades of experience; Population-based prevention of DDH in cerebral palsy: 20 years’ experience; Shoulder derotation in congenital plexus palsy; Back pain in the paediatric population: could MRI be the answer?; Intercondylar fracture of the humerus in children; The Dunn osteotomy in SUFE; Radiocapitellar line a myth!; Do ‘flatfooted’ children suffer?


Bone & Joint 360
Vol. 2, Issue 4 | Pages 32 - 32
1 Aug 2013
Brockwell J


Bone & Joint 360
Vol. 2, Issue 1 | Pages 1 - 1
1 Feb 2013
Ollivere BJ


Bone & Joint 360
Vol. 2, Issue 3 | Pages 35 - 38
1 Jun 2013

The June 2013 Children’s orthopaedics Roundup360 looks at: whether reaching a diagnosis is more difficult than previously thought; adolescent and paediatric DDH; the A-frame orthosis and Legg-Calvé-Perthes’ disease; failure of hip surgery in patients with cerebral palsy; adolescent rotator cuff injuries; paediatric peripheral nerve injuries; predicting residual deformity following Ponseti treatment; and the Dunn procedure.


Bone & Joint 360
Vol. 2, Issue 2 | Pages 10 - 12
1 Apr 2013

The April 2013 Hip & Pelvis Roundup360 looks at: hip cartilage and magnets; labral repair or resection; who benefits from injection; rotational osteotomy for osteonecrosis; whether ceramic implants risk fracture; dual articulation; and hydroxyapatite.