Objectives. Because posterior cruciate ligament (PCL) resection makes flexion
gaps wider in total knee replacement (TKR), preserving or sacrificing
a PCL affects the
Aims. This study aimed to investigate the estimated change in primary and revision arthroplasty rate in the Netherlands and Denmark for hips, knees, and shoulders during the COVID-19 pandemic in 2020 (COVID-period). Additional points of focus included the comparison of patient characteristics and hospital type (2019 vs COVID-period), and the estimated loss of quality-adjusted life years (QALYs) and impact on waiting lists. Methods. All hip, knee, and shoulder arthroplasties (2014 to 2020) from the Dutch Arthroplasty Register, and hip and knee arthroplasties from the Danish Hip and Knee Arthroplasty Registries, were included. The expected number of arthroplasties per month in 2020 was estimated using Poisson regression, taking into account changes in age and sex distribution of the general Dutch/Danish population over time, calculating observed/expected (O/E) ratios. Country-specific proportions of patient characteristics and hospital type were calculated per indication category (osteoarthritis/other elective/acute). Waiting list outcomes including QALYs were estimated by modelling virtual waiting lists including 0%, 5% and 10% extra capacity. Results. During COVID-period, fewer arthroplasties were performed than expected (Netherlands: 20%; Denmark: 5%), with the lowest O/E in April. In the Netherlands, more acute indications were prioritized, resulting in more American Society of Anesthesiologists grade III to IV patients receiving surgery. In both countries, no other patient prioritization was present. Relatively more arthroplasties were performed in private hospitals. There were no clinically relevant differences in revision arthroplasties between pre-COVID and COVID-period. Estimated total health loss depending on extra capacity ranged from: 19,800 to 29,400 QALYs (Netherlands): 1,700 to 2,400 QALYs (Denmark). With no extra capacity it will take > 30 years to deplete the waiting lists. Conclusion. The COVID-19 pandemic had an enormous negative effect on arthroplasty rates, but more in the Netherlands than Denmark. In the Netherlands, hip and shoulder patients with acute indications were prioritized. Private hospitals filled in part of the capacity
Aims. The COVID-19 pandemic led to a national suspension of “non-urgent” elective hip and knee arthroplasty. The study aims to measure the effect of the COVID-19 pandemic on total hip arthroplasty (THA) and total knee arthroplasty (TKA) volume in Scotland. Secondary objectives are to measure the success of restarting elective services and model the time required to bridge the
The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed.Aims
Methods
To review the evidence and reach consensus on recommendations for follow-up after total hip and knee arthroplasty. A programme of work was conducted, including: a systematic review of the clinical and cost-effectiveness literature; analysis of routine national datasets to identify pre-, peri-, and postoperative predictors of mid-to-late term revision; prospective data analyses from 560 patients to understand how patients present for revision surgery; qualitative interviews with NHS managers and orthopaedic surgeons; and health economic modelling. Finally, a consensus meeting considered all the work and agreed the final recommendations and research areas.Aims
Methods
The aim of this meta-analysis was to determine the pooled incidence of postoperative urinary retention (POUR) following total hip and knee arthroplasty (total joint replacement (TJR)) and to evaluate the risk factors and complications associated with POUR. Two authors conducted searches in PubMed, Embase, Web of Science, and Scopus on TJR and urinary retention. Eligible studies that reported the rate of POUR and associated risk factors for patients undergoing TJR were included in the analysis. Patient demographic details, medical comorbidities, and postoperative outcomes and complications were separately analyzed. The effect estimates for continuous and categorical data were reported as standardized mean differences (SMDs) and odds ratios (ORs) with 95% CIs, respectively.Aims
Methods
The present study aimed to investigate whether patients with inflammatory bowel disease (IBD) undergoing joint arthroplasty have a higher incidence of adverse outcomes than those without IBD. A comprehensive literature search was conducted to identify eligible studies reporting postoperative outcomes in IBD patients undergoing joint arthroplasty. The primary outcomes included postoperative complications, while the secondary outcomes included unplanned readmission, length of stay (LOS), joint reoperation/implant revision, and cost of care. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated using a random-effects model when heterogeneity was substantial.Aims
Methods
Data of high quality are critical for the meaningful interpretation of registry information. The National Joint Registry (NJR) was established in 2002 as the result of an unexpectedly high failure rate of a cemented total hip arthroplasty. The NJR began data collection in 2003. In this study we report on the outcomes following the establishment of a formal data quality (DQ) audit process within the NJR, within which each patient episode entry is validated against the hospital unit’s Patient Administration System and vice-versa. This process enables bidirectional validation of every NJR entry and retrospective correction of any errors in the dataset. In 2014/15 baseline average compliance was 92.6% and this increased year-on-year with repeated audit cycles to 96.0% in 2018/19, with 76.4% of units achieving > 95% compliance. Following the closure of the audit cycle, an overall compliance rate of 97.9% was achieved for the 2018/19 period. An automated system was initiated in 2018 to reduce administrative burden and to integrate the DQ process into standard workflows. Our processes and quality improvement results demonstrate that DQ may be implemented successfully at national level, while minimizing the burden on hospitals. Cite this article:
National joint registries under-report revisions for periprosthetic joint infection (PJI). We aimed to validate PJI reporting to the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) and the factors associated with its accuracy. We then applied these data to refine estimates of the total national burden of PJI. A total of 561 Australian cases of confirmed PJI were captured by a large, prospective observational study, and matched to data available for the same patients through the AOANJRR.Aims
Methods
Wound complications are reported in up to 10% hip and knee arthroplasties and there is a proven association between wound complications and deep prosthetic infections. In this randomised controlled trial (RCT) we explore the potential benefits of a portable, single use, incisional negative pressure wound therapy dressing (iNPWTd) on wound exudate, length of stay (LOS), wound complications, dressing changes and cost-effectiveness following total hip and knee arthroplasties. A total of 220 patients undergoing elective primary total hip and knee arthroplasties were recruited into in a non-blinded RCT. For the final analysis there were 102 patients in the study group and 107 in the control group.Objectives
Methods
Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters.Objectives
Methods