Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1256 - 1265
1 Nov 2022
Keene DJ Alsousou J Harrison P O’Connor HM Wagland S Dutton SJ Hulley P Lamb SE Willett K

Aims

To determine whether platelet-rich plasma (PRP) injection improves outcomes two years after acute Achilles tendon rupture.

Methods

A randomized multicentre two-arm parallel-group, participant- and assessor-blinded superiority trial was undertaken. Recruitment commenced on 28 July 2015 and two-year follow-up was completed in 21 October 2019. Participants were 230 adults aged 18 years and over, with acute Achilles tendon rupture managed with non-surgical treatment from 19 UK hospitals. Exclusions were insertion or musculotendinous junction injuries, major leg injury or deformity, diabetes, platelet or haematological disorder, medication with systemic corticosteroids, anticoagulation therapy treatment, and other contraindicating conditions. Participants were randomized via a central online system 1:1 to PRP or placebo injection. The main outcome measure was Achilles Tendon Rupture Score (ATRS) at two years via postal questionnaire. Other outcomes were pain, recovery goal attainment, and quality of life. Analysis was by intention-to-treat.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 728 - 734
1 Oct 2023
Fokkema CB Janssen L Roumen RMH van Dijk WA

Aims

In the Netherlands, general practitioners (GPs) can request radiographs. After a radiologically diagnosed fracture, patients are immediately referred to the emergency department (ED). Since 2020, the Máxima Medical Centre has implemented a new care pathway for minor trauma patients, referring them immediately to the traumatology outpatient clinic (OC) instead of the ED. We investigated whether this altered care pathway leads to a reduction in healthcare consumption and concomitant costs.

Methods

In this retrospective cohort study, patients were included if a radiologist diagnosed a fracture on a radiograph requested by the GP from August to October 2019 (control group) or August to October 2020 (research group), on weekdays between 8.30 am and 4.00 pm. The study compared various outcomes between groups, including the length of the initial hospital visit, frequency of hospital visits and medical procedures, extent of imaging, and healthcare expenses.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 726 - 732
16 Sep 2022
Hutchison A Bodger O Whelan R Russell ID Man W Williams P Bebbington A

Aims

We introduced a self-care pathway for minimally displaced distal radius fractures, which involved the patient being discharged from a Virtual Fracture Clinic (VFC) without a physical review and being provided with written instructions on how to remove their own cast or splint at home, plus advice on exercises and return to function.

Methods

All patients managed via this protocol between March and October 2020 were contacted by a medical secretary at a minimum of six months post-injury. The patients were asked to complete the Patient-Rated Wrist Evaluation (PRWE), a satisfaction questionnaire, advise if they had required surgery and/or contacted any health professional, and were also asked for any recommendations on how to improve the service. A review with a hand surgeon was organized if required, and a cost analysis was also conducted.


Aims

Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures.

Methods

A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 825 - 833
8 Oct 2021
Dailey HL Schwarzenberg P Webb, III EB Boran SAM Guerin S Harty JA

Aims

The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking.

Methods

Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing.


Bone & Joint Open
Vol. 2, Issue 3 | Pages 211 - 215
1 Mar 2021
Ng ZH Downie S Makaram NS Kolhe SN Mackenzie SP Clement ND Duckworth AD White TO

Aims

Virtual fracture clinics (VFCs) are advocated by recent British Orthopaedic Association Standards for Trauma and Orthopaedics (BOASTs) to efficiently manage injuries during the COVID-19 pandemic. The primary aim of this national study is to assess the impact of these standards on patient satisfaction and clinical outcome amid the pandemic. The secondary aims are to determine the impact of the pandemic on the demographic details of injuries presenting to the VFC, and to compare outcomes and satisfaction when the BOAST guidelines were first introduced with a subsequent period when local practice would be familiar with these guidelines.

Methods

This is a national cross-sectional cohort study comprising centres with VFC services across the UK. All consecutive adult patients assessed in VFC in a two-week period pre-lockdown (6 May 2019 to 19 May 2019) and in the same two-week period at the peak of the first lockdown (4 May 2020 to 17 May 2020), and a randomly selected sample during the ‘second wave’ (October 2020) will be eligible for the study. Data comprising local VFC practice, patient and injury characteristics, unplanned re-attendances, and complications will be collected by local investigators for all time periods. A telephone questionnaire will be used to determine patient satisfaction and patient-reported outcomes for patients who were discharged following VFC assessment without face-to-face consultation.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 69 - 75
1 Mar 2014
Parsons N Griffin XL Achten J Costa ML

Objectives

To study the measurement properties of a joint specific patient reported outcome measure, a measure of capability and a general health-related quality of life (HRQOL) tool in a large cohort of patients with a hip fracture.

Methods

Responsiveness and associations between the Oxford Hip Score (a hip specific measure: OHS), ICEpop CAPability (a measure of capability in older people: ICECAP-O) and EuroQol EQ-5D (general health-related quality of life measure: EQ-5D) were assessed using data available from two large prospective studies. The three outcome measures were assessed concurrently at a number of fixed follow-up time-points in a consecutive sequence of patients, allowing direct assessment of change from baseline, inter-measure associations and validity using a range of statistical methods.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 18 - 25
1 Jan 2016
Sims AL Parsons N Achten J Griffin XL Costa ML Reed MR

Background

Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes.

Design

This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:206–9.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 111 - 117
1 Jun 2012
von Recum J Matschke S Jupiter JB Ring D Souer J Huber M Audigé L

Objectives

To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type.

Methods

A total of 136 patients who received either a 2.4 mm (n = 61) or 3.5 mm (n = 75) distal radius locking compression plate (LCP DR) using a volar approach were followed over two years. The main outcome measurements included motion, grip strength, pain, and the scores of Gartland and Werley, the Short-Form 36 (SF-36) and the Disabilities of the Arm, Shoulder, and Hand (DASH). Differences between the treatment groups were evaluated using regression analysis and the likelihood ratio test with significance based on the Bonferroni corrected p-value of < 0.003.