Objectives . A rigorous approach to developing, delivering and documenting
rehabilitation within randomised controlled trials of surgical interventions
is required to underpin the generation of reliable and usable evidence.
This article describes the key processes used to ensure provision
of good quality and comparable rehabilitation to all participants
of a multi-centre randomised controlled trial comparing surgery
with conservative treatment of proximal humeral fractures in adults. Methods . These processes included the development of a patient information
leaflet on self-care during sling immobilisation, the development
of a basic treatment physiotherapy protocol that received input
and endorsement by specialist physiotherapists providing patient
care, and establishing an expectation for the provision of home
exercises. Specially designed forms were also developed to facilitate
reliable reporting of the physiotherapy care that patients received. Results. All three initiatives were successfully implemented, alongside
the measures to optimise the
Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded bone cement with no consensus regarding type, dose, or antibiotic content of the cement. This is the protocol for a randomized clinical trial to investigate the clinical and cost-effectiveness of high dose dual antibiotic-loaded cement in comparison to low dose single antibiotic-loaded cement in patients 60 years and over receiving a cemented hemiarthroplasty for an intracapsular hip fracture. The WHiTE 8 Copal Or Palacos Antibiotic Loaded bone cement trial (WHiTE 8 COPAL) is a multicentre, multi-surgeon, parallel, two-arm, randomized clinical trial. The pragmatic study will be embedded in the World Hip Trauma Evaluation (WHiTE) (ISRCTN 63982700). Participants, including those that lack capacity, will be allocated on a 1:1 basis stratified by recruitment centre to either a low dose single antibiotic-loaded bone cement or a high dose dual antibiotic-loaded bone cement. The primary analysis will compare the differences in deep SSI rate as defined by the Centers for Disease Control and Prevention within 90 days of surgery via medical record review and patient self-reported questionnaires. Secondary outcomes include UK Core Outcome Set for hip fractures, complications, rate of antibiotic prescription, resistance patterns of deep SSI, and resource use (more specifically, cost-effectiveness) up to four months post-randomization. A minimum of 4,920 patients will be recruited to obtain 90% power to detect an absolute difference of 1.5% in the rate of deep SSI at 90 days for the expected 3% deep SSI rate in the control group.Aims
Methods
The primary aim of this study was to identify independent predictors associated with nonunion and delayed union of tibial diaphyseal fractures treated with intramedullary nailing. The secondary aim was to assess the Radiological Union Scale for Tibial fractures (RUST) score as an early predictor of tibial fracture nonunion. A consecutive series of 647 patients who underwent intramedullary nailing for tibial diaphyseal fractures were identified from a trauma database. Demographic data, comorbidities, smoking status, alcohol consumption, use of non-steroidal anti-inflammatory drugs (NSAIDs), and steroid use were documented. Details regarding mechanism of injury, fracture classification, complications, and further surgery were recorded. Nonunion was defined as the requirement for revision surgery to achieve union. Delayed union was defined as a RUST score < 10 at six months postoperatively.Aims
Methods
The Fluid Lavage in Open Fracture Wounds (FLOW) trial was a multicentre,
blinded, randomized controlled trial that used a 2 × 3 factorial
design to evaluate the effect of irrigation solution (soap Participants completed the Short Form-12 (SF-12) and the EuroQol-5
Dimensions (EQ-5D) at baseline (pre-injury recall), at two and six
weeks, and at three, six, nine and 12-months post-fracture. We calculated
the Physical Component Score (PCS) and the Mental Component Score
(MCS) of the SF-12 and the EQ-5D utility score, conducted an analysis
using a multi-level generalized linear model, and compared differences
between the baseline and 12-month scores.Aims
Patients and Methods
Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for independent patients with displaced intracapsular fractures
of the proximal femur. The recognised alternatives are hemiarthroplasty
and total hip replacement. At present there is no established standard
of care, with both types of arthroplasty being used in many centres.
The principal advantages of total hip replacement are a functional
benefit over hemiarthroplasty and a reduced risk of revision surgery.
The principal criticism is the increased risk of dislocation. We
believe that an alternative acetabular component may reduce the
risk of dislocation but still provide the functional benefit of
total hip replacement in these patients. We therefore propose to
investigate the dislocation risk of a dual-mobility acetabular component
compared with standard polyethylene component in total hip replacement
for independent patients with displaced intracapsular fractures
of the proximal femur within the framework of the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for patients with unstable trochanteric proximal
femoral fractures. The recognised treatment alternatives are extramedullary
fixation usually with a sliding hip screw and intramedullary fixation
with a cephalomedullary nail. Current evidence suggests that best
results and lowest complication rates occur using a sliding hip screw.
Complications in these difficult fractures are relatively common
regardless of type of treatment. We believe that a novel device,
the X-Bolt dynamic plating system, may offer superior fixation over
a sliding hip screw with lower reoperation risk and better function.
We therefore propose to investigate the clinical effectiveness of
the X-bolt dynamic plating system compared with standard sliding
hip screw fixation within the framework of a the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. The National Hip Fracture
Audit currently provides a framework for service evaluation. This
evaluation is based upon the assessment of process rather than assessment
of patient-centred outcome and therefore it fails to provide meaningful
data regarding the clinical effectiveness of treatments. This study
aims to capture data from the cohort of patients who present with
a fracture of the proximal femur at a single United Kingdom Major
Trauma Centre. Patient-centred outcomes will be recorded and provide
a baseline cohort within which to test the clinical effectiveness
of experimental interventions.