Advertisement for orthosearch.org.uk
Results 1901 - 1920 of 2373
Results per page:
Bone & Joint 360
Vol. 4, Issue 2 | Pages 10 - 12
1 Apr 2015

The April 2015 Hip & Pelvis Roundup360 looks at: Goal-directed fluid therapy in hip fracture; Liberal blood transfusion no benefit in the longer term; Repeated measures: increased accuracy or compounded errors?; Peri-acetabular osteotomy safer than perhaps thought?; Obesity and peri-acetabular osteotomy: poor bedfellows; Stress fracture in peri-acetabular osteotomy; Infection and tantalum implants; Highly crosslinked polyethylene really does work


Bone & Joint 360
Vol. 4, Issue 2 | Pages 23 - 25
1 Apr 2015

The April 2015 Spine Roundup360 looks at: Hyperostotic spine in injury; App based back pain control; Interspinous process devices should be avoided in claudication; Robot assisted pedicle screws: fad or advance?; Vancomycin antibiotic power in spinal surgery; What to do with that burst fracture?; Increasing complexity of spinal fractures in major trauma pathways; Vitamin D and spinal fractures


Bone & Joint Research
Vol. 4, Issue 4 | Pages 65 - 69
1 Apr 2015
Kearney RS Parsons N Underwood M Costa ML

Objectives

The evidence base to inform the management of Achilles tendon rupture is sparse. The objectives of this research were to establish what current practice is in the United Kingdom and explore clinicians’ views on proposed further research in this area. This study was registered with the ISRCTN (ISRCTN68273773) as part of a larger programme of research.

Methods

We report an online survey of current practice in the United Kingdom, approved by the British Orthopaedic Foot and Ankle Society and completed by 181 of its members. A total of ten of these respondents were invited for a subsequent one-to-one interview to explore clinician views on proposed further research in this area.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 2 - 6
1 Apr 2015
Lever CJ Robinson AHN

Ankle replacements have improved significantly since the first reported attempt at resurfacing of the talar dome in 1962. We are now at a stage where ankle replacement offers a viable option in the treatment of end-stage ankle arthritis. As the procedure becomes more successful, it is important to reflect and review the current surgical outcomes. This allows us to guide our patients in the treatment of end-stage ankle arthritis. What is the better surgical treatment – arthrodesis or replacement?


Bone & Joint Research
Vol. 4, Issue 4 | Pages 50 - 55
1 Apr 2015
Sekimoto T Kurogi S Funamoto T Ota T Watanabe S Sakamoto T Hamada H Chosa E

Objectives

Excessive acetabular coverage is the most common cause of pincer-type femoroacetabular impingement. To date, an association between acetabular over-coverage and genetic variations has not been studied. In this study we investigated the association between single nucleotide polymorphisms (SNPs) of paralogous Homeobox (HOX)9 genes and acetabular coverage in Japanese individuals to identify a possible genetic variation associated with acetabular over-coverage.

Methods

We investigated 19 total SNPs in the four HOX9 paralogs, then focused in detail on seven of those located in the 3’ untranslated region of HOXB9 (rs8844, rs3826541, rs3826540, rs7405887, rs2303485, rs2303486, rs79931349) using a case-control association study. The seven HOXB9 SNPs were genotyped in 316 subjects who had all undergone radiological examination. The association study was performed by both single-locus and haplotype-based analyses.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 25 - 28
1 Apr 2015

The April 2015 Trauma Roundup360 looks at: Negative presure wound therapy in open tibial fractures; Priority-driven approach to pelvic injuries; Early surgery essential in hip fracture management; Sheer fractures to the posteromedial plateau; Fasciotomy closure under the spotlight; Why do patients die from hip fracture?; Acetabular fractures down the line; Biomechanics of femoral neck fractures reviewed


Bone & Joint 360
Vol. 4, Issue 2 | Pages 28 - 30
1 Apr 2015

The April 2015 Oncology Roundup360 looks at: New hope for skull base tumours; Survival but at what cost?; Synovial sarcoma beginning to be cracked?; Wound complications facing soft-tissue sarcoma surgeons; Amputation may offer no survival benefit over reconstruction; Giant cell tumour in the longer term; Intralesional treatment comparable with excision in GCT of the radius?; Imaging prior to oncological referral; And finally…


Bone & Joint 360
Vol. 4, Issue 2 | Pages 35 - 36
1 Apr 2015
Forward DP Lewis CP


Bone & Joint 360
Vol. 4, Issue 2 | Pages 17 - 20
1 Apr 2015

The April 2015 Wrist & Hand Roundup360 looks at: Non-operative hand fracture management; From the sublime to the ridiculous?; A novel approach to carpal tunnel decompression; Osteoporosis and functional scores in the distal radius; Ulnar variance and force distribution; Tourniquets in carpal tunnel under the spotlight; Scaphoid fractures reclassified; Osteoporosis and distal radial fracture fixation; PROMISing results in the upper limb


Bone & Joint 360
Vol. 4, Issue 2 | Pages 30 - 32
1 Apr 2015

The April 2015 Children’s orthopaedics Roundup360 looks at: Reducing the incidence of DDH – is ‘back carrying’ the answer?; Surgical approach and AVN may not be linked in DDH; First year routine radiographic follow up for scoliosis not necessary; Diagnosis of osteochondritis dessicans; Telemedicine in paediatrics; Regional anesthesia in supracondylar fractures?


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 484 - 491
1 Apr 2015
van Arkel RJ Amis AA Cobb JP Jeffers JRT

In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty.

Cite this article: Bone Joint J 2015; 97-B:484–91.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 39 - 40
1 Apr 2015
Wilson-MacDonald MJ


Bone & Joint 360
Vol. 4, Issue 2 | Pages 37 - 38
1 Apr 2015
Das A


Bone & Joint 360
Vol. 4, Issue 2 | Pages 20 - 23
1 Apr 2015

The April 2015 Shoulder & Elbow Roundup360 looks at: Distal clavicular resection not indicated in cuff repair?; Platelet-rich plasma in rotator cuff repair; Radial head geometry: time to change?; Heterotopic ossification in elbow trauma; Another look at heterotopic ossification in the humerus; Triceps on for total elbow arthroplasty?; Predicting outcomes in rotator cuff repair; Deltoid fatty infiltration and reverse shoulder arthroplasty


Bone & Joint 360
Vol. 4, Issue 2 | Pages 32 - 34
1 Apr 2015

The April 2015 Research Roundup360 looks at: MCID in grip strength and distal radial fracture; Experiencing rehab in a trial setting; Electrical stimulation and nerve recovery; Molecular diagnosis of TB?; Acetabular orientation: component and arthritis; Analgesia after knee arthroplasty; Bisphosphonate-associated femoral fractures


Bone & Joint 360
Vol. 4, Issue 2 | Pages 41 - 43
1 Apr 2015
Neal LA


Bone & Joint 360
Vol. 4, Issue 2 | Pages 1 - 1
1 Apr 2015
Ollivere B


Bone & Joint 360
Vol. 4, Issue 2 | Pages 15 - 17
1 Apr 2015

The April 2015 Foot & Ankle Roundup360 looks at: Plantar pressures linked to radiographs; Strength training for ankle instability?; Is weight loss good for your feet?; Diabetes and foot surgery complications; Tantalum for failed ankle arthroplasty?; Steroids, costs and Morton’s neuroma; Ankle arthritis and subtalar joint


Bone & Joint Research
Vol. 4, Issue 3 | Pages 38 - 44
1 Mar 2015
Thornton GM Reno CR Achari Y Morck DW Hart DA

Objectives

Ligaments which heal spontaneously have a healing process that is similar to skin wound healing. Menopause impairs skin wound healing and may likewise impair ligament healing. Our purpose in this study was to investigate the effect of surgical menopause on ligament healing in a rabbit medial collateral ligament model.

Methods

Surgical menopause was induced with ovariohysterectomy surgery in adult female rabbits. Ligament injury was created by making a surgical gap in the midsubstance of the medial collateral ligament. Ligaments were allowed to heal for six or 14 weeks in the presence or absence of oestrogen before being compared with uninjured ligaments. Molecular assessment examined the messenger ribonucleic acid levels for collagens, proteoglycans, proteinases, hormone receptors, growth factors and inflammatory mediators. Mechanical assessments examined ligament laxity, total creep strain and failure stress.


Bone & Joint Research
Vol. 4, Issue 3 | Pages 29 - 37
1 Mar 2015
Halim T Clarke IC Burgett-Moreno MD Donaldson TK Savisaar C Bowsher JG

Objectives

Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt–chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA).

Methods

Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range 5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments (5 mg) were inserted at ten intervals during the five million cycle (5 Mc) test.