Advertisement for orthosearch.org.uk
Results 2301 - 2320 of 2373
Results per page:
Bone & Joint 360
Vol. 1, Issue 3 | Pages 12 - 14
1 Jun 2012

The June 2012 Knee Roundup360 looks at: ACI and mosaicplasty; ACI after microfracture; exercise therapy and the degenerate medial meniscal tear; intra-articular bupivacaine or ropivacaine at knee arthroscopy; lateral trochlear inclination and patellofemoral osteoarthritis; bone loss and ACL reconstruction; assessing stability using the contralateral knee; tranexamic acid and a useful review of knee replacement.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 35 - 36
1 Jun 2012
Mason L


Bone & Joint Research
Vol. 1, Issue 6 | Pages 99 - 103
1 Jun 2012
Mason LW Tanaka H

Introduction

The aetiology of hallux valgus is almost certainly multifactoral. The biomechanics of the first ray is a common factor to most. There is very little literature examining the anatomy of the proximal metatarsal articular surface and its relationship to hallux valgus deformity.

Methods

We examined 42 feet from 23 specimens in this anatomical dissection study.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 34 - 34
1 Jun 2012
Redmond AD


Bone & Joint 360
Vol. 1, Issue 3 | Pages 30 - 33
1 Jun 2012

The June 2012 Research Roundup360 looks at: platelet-rich plasma; ageing, bone and mesenchymal stem cells; cytokines and the herniated intervertebral disc; ulcerative colitis, Crohn’s disease and anti-inflammatories; the effect of NSAIDs on bone healing; osteoporosis of the fractured hip; herbal medicine and recovery after acute muscle injury; and ultrasound and the time to fracture union.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 26 - 28
1 Jun 2012

The June 2012 Oncology Roundup360 looks at: avoiding pelvic hemipelvectomy; proximal femoral metastasis; extendible prostheses; rotationplasty; soft-tissue sarcomas; osteosarcoma of the pelvis; recurrent chondrosarcoma ; MRI and the differentiation between benign and malignant lesions; and malignant fibrous histiocytoma.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 21 - 23
1 Jun 2012

The June 2012 Spine Roundup360 looks at: back pain; spinal fusion for tuberculosis; anatomical course of the recurrent laryngeal nerve; groin pain with normal imaging; the herniated intervertebral disc; obesity’s effect on the spine; the medicolegal risks of cauda equina syndrome; and intravenous lidocaine use and failed back surgery syndrome.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 19 - 21
1 Jun 2012

The June 2012 Shoulder & Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 1 - 1
1 Jun 2012
Villar RN


Bone & Joint 360
Vol. 1, Issue 3 | Pages 28 - 30
1 Jun 2012

The June 2012 Children’s orthopaedics Roundup360 looks at; open reduction for DDH; growing rod instrumentation for scoliosis; acute patellar dislocation; management of the relapsed clubfoot; clubfoot in Iran; laughing gas and fracture manipulation; vascularised periosteal fibular grafting for nonunion; slipped upper femoral epiphysis; intramedullary leg lengthening and orthopaedic imaging and defensive medicine.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 14 - 16
1 Jun 2012

The June 2012 Foot & Ankle Roundup360 looks at: the Achilles tendon Total Rupture Score (ATRS); endoscopic treatment of Haglund’s syndrome; whether it is worth removing metalwork; hyaluronic acid injection; thromboembolic events after fracture fixation in the ankle; whether surgeons are as good as CT scans for OCD of the talus; proximal fractures of the fifth metatarsal; nerve blocks for hallux valgus surgery; chronic osteomyelitis in the non-diabetic patient; Charcot arthropathy.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 35 - 35
1 Jun 2012
Peate M


Bone & Joint Research
Vol. 1, Issue 6 | Pages 125 - 130
1 Jun 2012
Bøe BG Støen RØ Solberg LB Reinholt FP Ellingsen JE Nordsletten L

Objectives

An experimental rabbit model was used to test the null hypothesis, that there is no difference in new bone formation around uncoated titanium discs compared with coated titanium discs when implanted into the muscles of rabbits.

Methods

A total of three titanium discs with different surface and coating (1, porous coating; 2, porous coating + Bonemaster (Biomet); and 3, porous coating + plasma-sprayed hydroxyapatite) were implanted in 12 female rabbits. Six animals were killed after six weeks and the remaining six were killed after 12 weeks. The implants with surrounding tissues were embedded in methyl methacrylate and grinded sections were stained with Masson-Goldners trichrome and examined by light microscopy of coded sections.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives

We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone.

Methods

Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 24 - 26
1 Jun 2012

The June 2012 Trauma Roundup360 looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 35 - 35
1 Jun 2012
Donnelly L


Bone & Joint 360
Vol. 1, Issue 3 | Pages 16 - 19
1 Jun 2012

The June 2012 Wrist & Hand Roundup360 looks at; radial osteotomy and advanced Kienböck's disease; fixing the Bennett fracture; PEEK plates and four-corner arthrodesis,;carpal tunnel release and haemodialysis; degloved digits and the reverse radial forearm flap; occupational hand injuries; trapeziometacarpal osteoarthritis; fixing the fractured metacarpal neck and pyrocarbon implants for the destroyed PIPJ.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 104 - 110
1 Jun 2012
Swinteck BJ Phan DL Jani J Owen JR Wayne JS Mounasamy V

Objectives

The use of two implants to manage concomitant ipsilateral femoral shaft and proximal femoral fractures has been indicated, but no studies address the relationship of dynamic hip screw (DHS) side plate screws and the intramedullary nail where failure might occur after union. This study compares different implant configurations in order to investigate bridging the gap between the distal DHS and tip of the intramedullary nail.

Methods

A total of 29 left synthetic femora were tested in three groups: 1) gapped short nail (GSN); 2) unicortical short nail (USN), differing from GSN by the use of two unicortical bridging screws; and 3) bicortical long nail (BLN), with two angled bicortical and one unicortical bridging screws. With these findings, five matched-pairs of cadaveric femora were tested in two groups: 1) unicortical long nail (ULN), with a longer nail than USN and three bridging unicortical screws; and 2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally rotated 90°/sec until failure.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 2 - 4
1 Jun 2012
Cobb JP Andrews BL

In a global environment of rising costs and limited funds, robotic and computer-assisted orthopaedic technologies could provide the means to drive a necessary revolution in arthroplasty productivity. Robots have been used to operate on humans for 20 years, but the adoption of the technology has lagged behind that of the manufacturing industry. The use of robots in surgery should enable cost savings by reducing instrumentation and inventories, and improving accuracy. Despite these benefits, the orthopaedic community has been resistant to change. If the ergonomics and economics are right, robotic technology just might transform the provision of joint replacement.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 5 - 6
1 Jun 2012
Grimer RJ Jeys LM

Amputation was once widely practised for primary bone tumours of the limbs. Yet this situation has changed with limb salvage surgery becoming increasingly popular in the last 30 years. Many different techniques are now available. These include allografts, autografts, endoprostheses and allograft-prosthesis composites. This article reviews these methods, concentrating on the functional outcomes and complications that have been reported.