Advertisement for orthosearch.org.uk
Results 1 - 20 of 402
Results per page:
Bone & Joint Open
Vol. 4, Issue 2 | Pages 72 - 78
9 Feb 2023
Kingsbury SR Smith LKK Pinedo-Villanueva R Judge A West R Wright JM Stone MH Conaghan PG

Aims. To review the evidence and reach consensus on recommendations for follow-up after total hip and knee arthroplasty. Methods. A programme of work was conducted, including: a systematic review of the clinical and cost-effectiveness literature; analysis of routine national datasets to identify pre-, peri-, and postoperative predictors of mid-to-late term revision; prospective data analyses from 560 patients to understand how patients present for revision surgery; qualitative interviews with NHS managers and orthopaedic surgeons; and health economic modelling. Finally, a consensus meeting considered all the work and agreed the final recommendations and research areas. Results. The UK poSt Arthroplasty Follow-up rEcommendations (UK SAFE) recommendations apply to post-primary hip and knee arthroplasty follow-up. The ten-year time point is based on a lack of robust evidence beyond ten years. The term 'complex cases' refers to individual patient and surgical factors that may increase the risk for arthroplasty failure. For Orthopaedic Data Evaluation Panel (ODEP) 10A* minimum implants, it is safe to disinvest in routine follow-up from one to ten years post-non-complex hip and knee arthroplasty provided there is rapid access to orthopaedic review. For ODEP 10A* minimum implants in complex cases, or non-ODEP 10A* minimum implants, periodic follow-up post-hip and knee arthroplasty may be required from one to ten years. At ten years post-hip and knee arthroplasty, clinical and radiological evaluation is recommended. After ten years post-hip and knee arthroplasty, frequency of further follow-up should be based on the ten-year assessment; ongoing rapid access to orthopaedic review is still required. Conclusion. Complex cases, implants not meeting the ODEP 10A* criteria, and follow-up after revision surgery are not covered by this recommendation. Cite this article: Bone Jt Open 2023;4(2):72–78


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims. Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation. Methods. We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic. Results. From February 2018 to January 2019, there were 442 patients diagnosed as clinical scaphoid fractures. 122 patients (28%) self-referred back to the emergency department at two weeks. Following clinical review, 53 patients were discharged; MRI was booked for 69 patients (16%). Overall, six patients (< 2% of total; 10% of those scanned) had positive scans for a scaphoid fracture. There were no known missed fractures, long-term non-unions or malunions resulting from this pathway. Costs were saved by avoiding face-to-face clinical review and MRI scanning. Conclusion. A patient-focused opt-in approach is safe and effective to managing the suspected occult (clinical) scaphoid fracture. Cite this article: Bone Jt Open 2024;5(2):117–122


Bone & Joint Open
Vol. 4, Issue 2 | Pages 79 - 86
10 Feb 2023
McLaughlin JR Johnson MA Lee KR

Aims. The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). Methods. The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four. Results. Seven femoral components (18%) required revision, and none for septic loosening. Four well fixed stems were removed during acetabular revision and three were revised for late infection. One femoral component (3%) was loose by radiological criteria. The mean Harris Hip Score improved from 47 points (SD 4.62) preoperatively to 83 points (SD 9.27) at final follow-up. With revision for any reason as the endpoint, survival of the femoral component was 80% (95% confidence interval (CI) 61% to 90%) at 32 years. With revision for aseptic loosing femoral component, survival was 99% (95% CI 93% to 99%). Conclusion. With regards to aseptic loosening, the Taperloc femoral component provides excellent fixation at a mean follow-up of 32 years. Cite this article: Bone Jt Open 2023;4(2):79–86


Bone & Joint Open
Vol. 5, Issue 11 | Pages 971 - 976
5 Nov 2024
Baker G Hill J O'Neill F McChesney J Stevenson M Beverland D

Aims. In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results. The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant radiolucent lines at ten years compared to 65 (25.5%) at six years. Conclusion. When compared to the original review, there has been a significant deterioration in pain score, OHS, radiograph appearance, and, most critically, survival has fallen to 91.2%, which does not meet the Orthopaedic Data Evaluation Panel (ODEP) 10 A* 95% threshold. Although this bearing is no longer on the market, 2.5% were bearing-related revisions, which have relevance to the discussion around modular dual-mobility implants that have a similar metal interface


Bone & Joint Open
Vol. 5, Issue 9 | Pages 736 - 741
4 Sep 2024
Farr S Mataric T Kroyer B Barik S

Aims. The paediatric trigger thumb is a distinct clinical entity with unique anatomical abnormalities. The aim of this study was to present the long-term outcomes of A1 pulley release in idiopathic paediatric trigger thumbs based on established patient-reported outcome measures. Methods. This study was a cross-sectional, questionnaire-based study conducted at a tertiary care orthopaedic centre. All cases of idiopathic paediatric trigger thumbs which underwent A1 pulley release between 2004 and 2011 and had a minimum follow-up period of ten years were included in the study. The abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH) was administered as an online survey, and ipsi- and contralateral thumb motion was assessed. Results. A total of 67 patients completed the survey, of whom 63 (94%) had full interphalangeal joint extension or hyperextension. Severe metacarpophalangeal joint hyperextension (> 40°) was documented in 15 cases (22%). The median QuickDASH score was 0 (0 to 61), indicating excellent function at a median follow-up of 15 years (10 to 19). Overall satisfaction was high, with 56 patients (84%) reporting the maximal satisfaction score of 5. Among 37 patients who underwent surgery at age ≤ two years, 34 (92%) reported the largest satisfaction, whereas this was the case for 22 of 30 patients (73%) with surgery at aged > two years (p = 0.053). Notta’s nodule resolved in 49 patients (73%) at final follow-up. No residual triggering or revision surgery was observed. Conclusion. Surgical release of A1 pulley in paediatric trigger thumb is an acceptable procedure with excellent functional long-term outcomes. There was a trend towards higher satisfaction with earlier surgery among the patients. Cite this article: Bone Jt Open 2024;5(9):736–741


Bone & Joint Open
Vol. 2, Issue 5 | Pages 344 - 350
31 May 2021
Ahmad SS Hoos L Perka C Stöckle U Braun KF Konrads C

Aims. The follow-up interval of a study represents an important aspect that is frequently mentioned in the title of the manuscript. Authors arbitrarily define whether the follow-up of their study is short-, mid-, or long-term. There is no clear consensus in that regard and definitions show a large range of variation. It was therefore the aim of this study to systematically identify clinical research published in high-impact orthopaedic journals in the last five years and extract follow-up information to deduce corresponding evidence-based definitions of short-, mid-, and long-term follow-up. Methods. A systematic literature search was performed to identify papers published in the six highest ranked orthopaedic journals during the years 2015 to 2019. Follow-up intervals were analyzed. Each article was assigned to a corresponding subspecialty field: sports traumatology, knee arthroplasty and reconstruction, hip-preserving surgery, hip arthroplasty, shoulder and elbow arthroplasty, hand and wrist, foot and ankle, paediatric orthopaedics, orthopaedic trauma, spine, and tumour. Mean follow-up data were tabulated for the corresponding subspecialty fields. Comparison between means was conducted using analysis of variance. Results. Of 16,161 published articles, 590 met the inclusion criteria. Of these, 321 were of level IV evidence, 176 level III, 53 level II, and 40 level I. Considering all included articles, a long-term study published in the included high impact journals had a mean follow-up of 151.6 months, a mid-term study of 63.5 months, and a short-term study of 30.0 months. Conclusion. The results of this study provide evidence-based definitions for orthopaedic follow-up intervals that should provide a citable standard for the planning of clinical studies. A minimum mean follow-up of a short-term study should be 30 months (2.5 years), while a mid-term study should aim for a mean follow-up of 60 months (five years), and a long-term study should aim for a mean of 150 months (12.5 years). Level of Evidence: Level I. Cite this article: Bone Jt Open 2021;2(5):344–350


Bone & Joint Open
Vol. 3, Issue 5 | Pages 375 - 382
5 May 2022
Teunissen JS van der Oest MJW Selles RW Ulrich DJO Hovius SER van der Heijden B

Aims. The primary aim of this study was to describe long-term patient-reported outcomes after ulna shortening osteotomy for ulna impaction syndrome. Methods. Overall, 89 patients treated between July 2011 and November 2017 who had previously taken part in a routine outcome evaluation up to 12 months postoperatively were sent an additional questionnaire in February 2021. The primary outcome was the Patient-Rated Wrist and Hand Evaluation (PRWHE) total score. Secondary outcomes included patient satisfaction with treatment results, complications, and subsequent treatment for ulnar-sided wrist pain. Linear mixed models were used to compare preoperative, 12 months, and late follow-up (ranging from four to nine years) PRWHE scores. Results. Long-term outcomes were available in 66 patients (74%) after a mean follow-up of six years (SD 1). The mean PRWHE total score improved from 63 before surgery to 19 at late follow-up (difference in means (Δ) 44; 95% confidence interval (CI) 39 to 50; p = <0.001). Between 12 months and late follow-up, the PRWHE total score also improved (Δ 12; 95% CI 6 to 18; p = < 0.001). At late follow-up, 14/66 of patients (21%) reported a PRWHE total score of zero, whereas this was 3/51 patients (6%) at 12 months (p = 0.039). In all, 58/66 patients (88%) would undergo the same treatment again under similar circumstances. Subsequent treatment (total n = 66; surgical n = 57) for complications or recurrent symptoms were performed in 50/66 patients (76%). The most prevalent type of reoperation was hardware removal in 42/66 (64%), and nonunion occurred in 8/66 (12%). Conclusion. Ulna shortening osteotomy improves patient-reported pain and function that seems to sustain at late follow-up. While satisfaction levels are generally high, reoperations such as hardware removal are common. Cite this article: Bone Jt Open 2022;3(5):375–382


Bone & Joint Open
Vol. 2, Issue 5 | Pages 338 - 343
21 May 2021
Harvey J Varghese BJ Hahn DM

Aims. Displaced distal radius fractures were investigated at a level 1 major trauma centre during the COVID-19 2020 lockdown due to the implementation of temporary changes in practice. The primary aim was to establish if follow-up at one week in place of the 72-hour British Orthopaedic Association Standards for Trauma & Orthopaedics (BOAST) guidance was safe following manipulation under anaesthetic. A parallel adaptation during lockdown was the non-expectation of Bier’s block. The secondary aim was to compare clinical outcomes with respect to block type. Methods. Overall, 90 patients were assessed in a cross-sectional cohort study using a mixed, retrospective-prospective approach. Consecutive sampling of 30 patients pre-lockdown (P1), 30 during lockdown (P2), and 30 during post-lockdown (P3) was applied. Type of block, operative status, follow-up, and complications were extracted. Primary endpoints were early complications (≤ one week). Secondary endpoints were later complications including malunion, delayed union or osteotomy. Results. In P1, 86.6% of patients were seen between days one to three, 26.7% in P2, and 56.7% in P3. There were no documented complications from days one to three. Operative rate was 35.5%, which did not vary significantly (p= 0.712). Primary endpoints occurred between day four to seven, and included one patient each period treated for plaster cast pain. Secondary endpoints in P1 included delayed union (one patient). During P2, this included malunion (one patient), a pressure sore (one patient) and ulnar cutaneous nerve symptoms (two patients). In P3, malunion was identified in one patient. Mean follow-up was six months (4 to 9) with union rate 96%. Change in block practice varied significantly (p =<0.05). The risk ratio of complications using regional block (Bier’s) over haematoma block was 0.65. Conclusion. Follow-up adaptations during lockdown did not adversely affect patient outcomes. Regional anaesthesia is gold standard for manipulation of displaced distal radial fractures. Cite this article: Bone Jt Open 2021;2(5):338–343


Bone & Joint Open
Vol. 2, Issue 1 | Pages 33 - 39
14 Jan 2021
McLaughlin JR Lee KR Johnson MA

Aims. We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods. A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results. Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion. The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well. Cite this article: Bone Jt Open 2021;2(1):33–39


Bone & Joint Open
Vol. 3, Issue 4 | Pages 275 - 283
1 Apr 2022
Ross LA O'Rourke SC Toland G MacDonald DJ Clement ND Scott CEH

Aims. The aim of this study was to determine satisfaction rates after hip and knee arthroplasty in patients who did not respond to postoperative patient-reported outcome measures (PROMs), characteristics of non-responders, and contact preferences to maximize response rates. Methods. A prospective cohort study of patients planned to undergo hip arthroplasty (n = 713) and knee arthroplasty (n = 737) at a UK university teaching hospital who had completed preoperative PROMs questionnaires, including the EuroQol five-dimension health-related quality of life score, and Oxford Hip Score (OHS) and Oxford Knee Score (OKS). Follow-up questionnaires were sent by post at one year, including satisfaction scoring. Attempts were made to contact patients who did not initially respond. Univariate, logistic regression, and receiver operator curve analysis was performed. Results. At one year, 667 hip patients (93.5%) and 685 knee patients (92.9%) had undergone surgery and were alive. No response was received from 151/667 hip patients (22.6%), 83 (55.0%) of whom were ultimately contacted); or from 108/685 knee patients (15.8%), 91 (84.3%) of whom were ultimately contacted. There was no difference in satisfaction after arthroplasty between initial non-responders and responders for hips (74/81 satisfied vs 476/516 satisfied; p = 0.847) or knees (81/93 satisfied vs 470/561 satisfied; p = 0.480). Initial non-response and persistent non-response was associated with younger age, higher BMIs, and worse preoperative PROMs for both hip and knee patients (p < 0.050). Being in employment was associated with persistent non-response for hip patients (p = 0.047). Multivariate analysis demonstrated that younger age (p < 0.038), higher BMI (p = 0.018), and poorer preoperative OHS (p = 0.031) were independently associated with persistent non-response to hip PROMs. No independent associations were identified for knees. Using a threshold of > 66.4 years predicted a preference for contact by post (area under the curve 0.723 (95% confidence interval (CI) 0.647 to 0.799; p < 0.001, though this CI crosses the 0.7 limit considered reliable). Conclusion. The majority of initial non-responders were ultimately contactable with effort. Satisfaction rates were not inferior in patients who did not initially respond to PROMs. Cite this article: Bone Jt Open 2022;3(4):275–283


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes. Cite this article: Bone Jt Open 2021;2(12):1075–1081


Bone & Joint Open
Vol. 4, Issue 11 | Pages 846 - 852
8 Nov 2023
Kim RG Maher AW Karunaratne S Stalley PD Boyle RA

Aims. Tenosynovial giant cell tumour (TGCT) is a rare benign tumour of the musculoskeletal system. Surgical management is fraught with challenges due to high recurrence rates. The aim of this study was to describe surgical treatment and evaluate surgical outcomes of TGCT at an Australian tertiary referral centre for musculoskeletal tumours and to identify factors affecting recurrence rates. Methods. A prospective database of all patients with TGCT surgically managed by two orthopaedic oncology surgeons was reviewed. All cases irrespective of previous treatment were included and patients without follow-up were excluded. Pertinent tumour characteristics and surgical outcomes were collected for analysis. Results. There were 111 total cases included in the study; 71 (64%) were female, the mean age was 36 years (SD 13.6), and the knee (n = 64; 57.7%) was the most commonly affected joint. In all, 60 patients (54.1%) had diffuse-type (D-TGCT) disease, and 94 patients (84.7%) presented therapy-naïve as "primary cases" (PC). The overall recurrence rate was 46.8% for TGCT. There was a statistically significant difference in recurrence rates between D-TGCT and localized disease (75.0% vs 13.7%, relative risk (RR) 3.40, 95% confidence interval (CI) 2.17 to 5.34; p < 0.001), and for those who were referred in the ”revision cases” (RC) group compared to the PC group (82.4% vs 48.9%, RR 1.68, 95% CI 1.24 to 2.28; p = 0.011). Age, sex, tumour volume, and mean duration of symptoms were not associated with recurrence (p > 0.05). Conclusion. Recurrence rates remain high even at a tertiary referral hospital. Highest rates are seen in D-TGCT and “revision cases”. Due to the risks of recurrence, the complexity of surgery, and the need for adjuvant therapy, this paper further supports the management of TGCT in a tertiary referral multi-disciplinary orthopaedic oncology service. Cite this article: Bone Jt Open 2023;4(11):846–852


Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims

The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs).

Methods

This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 490 - 495
4 Jul 2023
Robinson PG Creighton AP Cheng J Dines JS Su EP Gulotta LV Padgett D Demetracopoulos C Hawkes R Prather H Press JM Clement ND

Aims

The primary aim of this prospective, multicentre study is to describe the rates of returning to golf following hip, knee, ankle, and shoulder arthroplasty in an active golfing population. Secondary aims will include determining the timing of return to golf, changes in ability, handicap, and mobility, and assessing joint-specific and health-related outcomes following surgery.

Methods

This is a multicentre, prospective, longitudinal study between the Hospital for Special Surgery, (New York City, New York, USA) and Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, (Edinburgh, UK). Both centres are high-volume arthroplasty centres, specializing in upper and lower limb arthroplasty. Patients undergoing hip, knee, ankle, or shoulder arthroplasty at either centre, and who report being golfers prior to arthroplasty, will be included. Patient-reported outcome measures will be obtained at six weeks, three months, six months, and 12 months. A two-year period of recruitment will be undertaken of arthroplasty patients at both sites.


Bone & Joint Open
Vol. 1, Issue 4 | Pages 80 - 87
24 Apr 2020
Passaplan C Gautier L Gautier E

Aims. Our retrospective analysis reports the outcome of patients operated for slipped capital femoral epiphysis using the modified Dunn procedure. Results, complications, and the need for revision surgery are compared with the recent literature. Methods. We retrospectively evaluated 17 patients (18 hips) who underwent the modified Dunn procedure for the treatment of slipped capital femoral epiphysis. Outcome measurement included standardized scores. Clinical assessment included ambulation, leg length discrepancy, and hip mobility. Radiographically, the quality of epiphyseal reduction was evaluated using the Southwick and Alpha-angles. Avascular necrosis, heterotopic ossifications, and osteoarthritis were documented at follow-up. Results. At a mean follow-up of more than nine years, the mean modified Harris Hip score was 88.7 points, the Hip Disability and Osteoarthritis Outcome Score (HOOS) 87.4 , the Merle d’Aubigné Score 16.5 points, and the UCLA Activity Score 8.4. One patient developed a partial avascular necrosis of the femoral head, and one patient already had an avascular necrosis at the time of delayed diagnosis. Two hips developed osteoarthritic signs at 14 and 16 years after the index operation. Six patients needed a total of nine revision surgeries. One operation was needed for postoperative hip subluxation, one for secondary displacement and implant failure, two for late femoroacetabular impingement, one for femoroacetabular impingement of the opposite hip, and four for implant removal. Conclusion. Our series shows good results and is comparable to previous published studies. The modified Dunn procedure allows the anatomic repositioning of the slipped epiphysis. Long-term results with subjective and objective hip function are superior, avascular necrosis and development of osteoarthritis inferior to other reported treatment modalities. Nevertheless, the procedure is technically demanding and revision surgery for secondary femoroacetabular impingement and implant removal are frequent. Cite this article: 2020;1-4:80–87


Bone & Joint Open
Vol. 1, Issue 10 | Pages 653 - 662
20 Oct 2020
Rahman L Ibrahim MS Somerville L Teeter MG Naudie DD McCalden RW

Aims. To compare the in vivo long-term fixation achieved by two acetabular components with different porous ingrowth surfaces using radiostereometric analysis (RSA). Methods. This was a minimum ten-year follow-up of a prospective randomized trial of 62 hips with two different porous ingrowth acetabular components. RSA exams had previously been acquired through two years of follow-up. Patients returned for RSA examination at a minimum of ten years. In addition, radiological appearance of these acetabular components was analyzed, and patient-reported outcome measures (PROMs) obtained. Results. In all, 15 hips were available at ten years. There was no statistically significant difference in PROMS between the two groups; PROMs were improved at ten years compared to preoperative scores. Conventional radiological assessment revealed well-fixed components. There was minimal movement for both porous surfaces in translation (X, Y, Z, 3D translation in mm (median and interquartile range (IQR)), StikTite (Smith and Nephew, Memphis, Tennessee, USA): 0.03 (1.08), 0.12 (0.7), 0.003 (2.3), 0.37 (0.30), and Roughcoat (Smith and Nephew): -0.6 (0.59),–0.1 (0.49), 0.1 (1.12), 0.48 (0.38)), and rotation (X, Y, Z rotation in degrees (median and IQR), (Stiktite: -0.4 (3), 0.28 (2), -0.2 (1), and Roughcoat: - 0.4 (1),–0.1 (1), 0.2 (2)). There was no statistically significant difference between the two cohorts (p-value for X, Y, Z, 3D translation - 0.54, 0.46, 0.87, 0.55 and for X, Y, Z rotation - 0.41, 0.23, 0.23 respectively) at ten years. There was significant correlation between two years and ten years 3D translation for all components (r = 0.81(p =< 0.001)). Conclusion. Both porous ingrowth surfaces demonstrated excellent fixation on plain radiographs and with RSA at ten years. Short-term RSA data are good predictors for long-term migration data


Bone & Joint Open
Vol. 5, Issue 10 | Pages 911 - 919
21 Oct 2024
Clement N MacDonald DJ Hamilton DF Gaston P

Aims. The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year follow-up period, and whether patient-related factors were associated with loss to follow-up and mortality risk. Methods. Long-term follow-up of a randomized controlled trial was undertaken. A total of 212 patients were allocated a Triathlon or a Kinemax TKA. Patients were assessed preoperatively, and one, three, eight, and 12 years postoperatively using the Oxford Knee Score (OKS). Reasons for patient lost to follow-up, mortality, and revision were recorded. Results. A total of 94 patients completed 12-year functional follow-up (62 females, mean age 66 years (43 to 82) at index surgery). There was a clinically significantly greater improvement in the OKS at one year (mean difference (MD) 3.0 (95% CI 0.4 to 5.7); p = 0.027) and three years (MD 4.7 (95% CI 1.9 to 7.5); p = 0.001) for the Triathlon group, but no differences were observed at eight (p = 0.331) or 12 years’ (p = 0.181) follow-up. When assessing the OKS in the patients surviving to 12 years, the Triathlon group had a clinically significantly greater improvement in the OKS (marginal mean 3.8 (95% CI 0.2 to 7.4); p = 0.040). Loss to functional follow-up (53%, n = 109/204) was independently associated with older age (p = 0.001). Patient mortality was the major reason (56.4%, n = 62/110) for loss to follow-up. Older age (p < 0.001) and worse preoperative OKS (p = 0.043) were independently associated with increased mortality risk. An age at time of surgery of ≥ 72 years was 75% sensitive and 74% specific for predicting mortality with an area under the curve of 78.1% (95% CI 70.9 to 85.3; p < 0.001). Conclusion. The Triathlon TKA was associated with clinically meaningful greater improvement in knee-specific outcome when compared to the Kinemax TKA. Loss to follow-up at 12 years was a limitation, and studies planning longer-term functional assessment could limit their cohort to patients aged under 72 years. Cite this article: Bone Jt Open 2024;5(10):911–919


Bone & Joint Open
Vol. 5, Issue 10 | Pages 825 - 831
3 Oct 2024
Afghanyar Y Afghanyar B Loweg L Drees P Gercek E Dargel J Rehbein P Kutzner KP

Aims. Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years’ follow-up. Methods. This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up. Results. Clinical assessment showed persistent major improvement in all scores. On radiological assessment, only one case showed a lucent line (without symptoms). At last follow-up, wear and migration were below the critical thresholds. No cup-related revisions were needed, indicating an outstanding survival rate of 100%. Conclusion. Isoelastic VEPE cups offer high success rates and may prevent osteolysis, aseptic loosening, and the need for revision surgeries in the long term. However, longer follow-up is needed to validate our findings and confirm the advantages offered by this cup. Cite this article: Bone Jt Open 2024;5(10):825–831


Bone & Joint Open
Vol. 4, Issue 2 | Pages 53 - 61
1 Feb 2023
Faraj S de Windt TS van Hooff ML van Hellemondt GG Spruit M

Aims. The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA). Methods. Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance. Results. A total of 18 females with 22 CTACs who had a mean age of 73.5 years (SD 7.7) were included. A significant improvement was found in HOOS (p < 0.0001), mOHS (p < 0.0001), EQ-5D-3L utility (p = 0.003), EQ-5D-3L NRS (p = 0.013), VAS pain rest (p = 0.008), and VAS pain activity (p < 0.0001) between baseline and final follow-up. Minimal clinically important improvement in mOHS and the HOOS Physical Function Short Form (HOOS-PS) was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage. Conclusion. CTAC in patients with THA acetabular loosening and PD can result in stable constructs and significant improvement in functioning and health-related quality of life at two years' follow-up. Further follow-up is necessary to determine the mid- to long-term outcome. Cite this article: Bone Jt Open 2023;4(2):53–61


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims. Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial. Methods. The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival. Results. A total of 407 patients who underwent UKA were included in the study. The mean age of patients was 61.8 years, and the mean follow-up period of the patients was 91.7 months. The mean Knee Society Score (KSS) preoperatively and at the last follow-up were 64.2 and 89.7, respectively (p = 0.001). Overall, 28 patients (6.9%) with UKA underwent revision due to prosthesis loosening (16 patients), dislocation (eight patients), and persistent pain (four patients). Cox proportional hazards model analysis identified malposition of the prostheses as a high-risk factor for UKA failure (p = 0.007). Kaplan-Meier analysis revealed that the five-year survival rate of the group with malposition was 85.1%, which was significantly lower than that of the group with normal position (96.2%; p < 0.001). Conclusion. UKA constitutes an effective method for treating anteromedial knee OA, with an excellent five-year survival rate. Aseptic loosening caused by prosthesis malposition was identified as the main cause of UKA failure. Surgeons should pay close attention to prevent the potential occurrence of this problem. Cite this article: Bone Jt Open 2023;4(12):914–922