Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 59 - 59
10 Feb 2023
Hancock D Morley D Wyatt M Roberts P Zhang J van Dalen J
Full Access

When removing femoral cement in revision hip surgery, creating an anterior femoral cortical window is an attractive alternative to extended trochanteric osteotomy. We describe our experience and evolution of this technique, the clinical and radiological results, and functional outcomes.

Between 2006 and 2021 we used this technique in 22 consecutive cases at Whanganui Hospital, New Zealand. The average age at surgery was 74 years (Range 44 to 89 years). 16 cases were for aseptic loosening: six cases for infection.

The technique has evolved to be more precise and since 2019 the combination of CT imaging and 3-D printing technology has allowed patient-specific (PSI) jigs to be created (6 cases). This technique now facilitates cement removal by potentiating exposure through an optimally sized anterior femoral window.

Bone incorporation of the cortical window and functional outcomes were assessed in 22 cases, using computer tomography and Oxford scores respectively at six months post revision surgery. Of the septic cases, five went onto successful stage two procedures, the other to a Girdlestone procedure.

On average, 80% bony incorporation of the cortical window occurred (range 40 −100%). The average Oxford hip score was 37 (range 22 – 48). Functional outcome (Oxford Hip) scores were available in 11 cases (9 pre-PSI jig and 2 using PSI jig). There were two cases with femoral component subsidence (1 using the PSI jig).

This case series has shown the effectiveness of removing a distal femoral cement mantle using an anterior femoral cortical window, now optimized by using a patient specific jig with subsequent reliable bony integration, and functional outcomes comparable with the mean score for revision hip procedures reported in the New Zealand Joint Registry.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 315 - 315
1 May 2006
Dempsey S Manson J van Dalen J
Full Access

To investigate the significance of a cluster of cases of glenohumeral chondrolysis occuring following the intra-articular injection of methylene blue to assess rotator cuff integrity during open anterior acromioplasty.

All cases of acromioplasty during the period 1999 to 2004 were reviewed to determine the incidence of chondrolysis with and without methylene blue injection.

There was a significantly higher incidence of chondrolysis following intra-articular injection of methylene blue.

The association of intra-articular methylene blue with chondrolysis has not been previously described in the literature. We conclude that methylene blue should not be used for intra-articular injection.