Vol. 103-B, Issue SUPP_12 | Pages 10 - 10
1 Oct 2021
Zein A Elhalawany AS Ali M Cousins G
Full Access

Despite multiple published reviews, the optimum method of correction and stabilisation of Blount's disease remains controversial. The purpose of this study is to evaluate the clinical and radiological outcomes of acute correction of late-onset tibial vara by percutaneous proximal tibial osteotomy with circular external fixation using two simple rings. This technique was developed to minimise cost in a context of limited resources.

This study was conducted between 2016 and 2020. We retrospectively reviewed the clinical notes and radiographs of 30 patients (32tibiae) who had correction of late-onset tibia by proximal tibial osteotomy and Ilizarov external fixator. All cases were followed up to 2 years.

The mean proximal tibial angle was 65.7° (±7.8) preoperatively and 89.8° (±1.7) postoperatively. The mean mechanical axis deviation improved from 56.2 (±8.3) preoperatively to 2.8 (±1.6) mm postoperatively. The mean femoral-tibial shaft angle was changed from – 34.3° (±6.7) preoperatively to 5.7° (±2.8) after correction. Complications included overcorrection (9%) and pin tract infection (25%). At final follow up, all patients had full knee range of motion and normal function. All cases progressed to union and there were no cases of recurrence of deformity.

This simple procedure provides secure fixation allowing early weight bearing and early return to function. It can be used in the context of health care systems with limited resources. It has a relatively low complication rate. Our results suggest that acute correction and simple circular frame fixation is an excellent treatment choice for cases of late-onset tibia vara, especially in severe deformities.