Arthrofibrosis remains a persistent complication following total knee arthroplasty (TKA). Although manipulation under anesthesia (MUA) is an effective early treatment, the risks and value of this procedure beyond 3 months after TKA remain controversial. The purpose of this study was to examine the safety and efficacy of late MUAs for arthrofibrosis. From our institutional total joint registry, 82 TKAs (77 patients) who underwent MUA >3 months after primary (83%) or revision (17%) TKA were identified. Mean time to MUA was 7 months: 66% performed between 4–6 months, 18% between 7–12 months, 16% beyond 12 months. MUAs were coupled with arthroscopic assistance in 26% (12% limited lysis of adhesions, 13% formal arthroscopic debridement). Mean age was 61 years, 59% females, and mean BMI was 33kg/m2. Mean follow-up was 5 years.Introduction
Methods
Mechanical or corrosive failure of total knee arthroplasties (TKAs) is difficult to diagnose with current laboratory and radiographic analyses. As such, the goal of this study was to determine the mean blood concentration of cobalt, chromium, and titanium in a series of revision TKAs with mechanical implant failure and evaluate whether they facilitated identification of the underlying TKA failure mechanism. Serum cobalt, chromium, and titanium levels and synovial fluid characteristics were evaluated in 12 patients (13 aseptic revision TKAs) who underwent revision TKA between 2000 and 2020 at a single academic institution for mechanical implant failure or corrosion. Seventy-five percent were re-revisions of previously revised TKAs. Mean time to revision was 6 years. Modular metallic junctions were present in 100%. Twenty-five percent did not have another Introduction
Methods