The only existing classification of Müller-Weiss Disease (MWD), based solely on Méary's angle, serves neither as guide for prognosis nor treatment. This accounts for lack of gold standard in its management. Navicular compression, medial extrusion, Kite's angle and metatarsal lengths were measured on all radiographs of 95 feet with MWD. Joints involved, presence and location of navicular fracture were recorded.Background
Methods
Wound surveillance has been reported to result in a significant fall in the incidence of wound sepsis in total knee arthroplasty (TKA). However, there is currently little guidance on the definition of surgical wound infection that is best to be used for surveillance. The purpose of this study was to assess the agreement between three common definitions of surgical wound infection as a performance indicator in TKA; (a) the CDC 1992 definition, (b) the NINSS modification of the CDC definition and (c) the ASEPSIS scoring method applied to the same series of surgical wounds. A prospective study of 500 surgical wounds in patients who underwent knee arthroplasties between May 2002 and December 2004 from a single tertiary centre were assessed according to the different definitions of surgical wound infection.Introduction
Methods
To assess the usefulness of radiographs alone to evaluate acute midfoot/forefoot injuries. We believe that foot injuries are often under-estimated and that CT scans should be routinely obtained to aid in their management and avoid additional morbidity for patients. In 26 months, 255 patients had foot injuries requiring X-Rays. Of these patients, 94 (37%) had primary radiographs indicating midfoot or forefoot fractures, and 28 had subsequent CT scans. Radiographs were retrospectively re-evaluated with respect to fracture location, type, mechanism of injury and then compared with CT results.Objective
Materials & Methods
The management of chondral lesions in the knee, especially in young fit patients, remains an area of considerable controversy. Articular cartilage repair or reconstruction techniques may offer these patients alternatives to arthroplasty or realignment osteotomy. The TruFit plug (Smith & Nephew, London, UK) is a synthetic biphasic polymer scaffold that is designed for implantation at the site of a focal chondral defect. It is intended to resorb and allow tissue ingrowth 6-9 months following implantation and may be placed either arthroscopically or via an open approach depending on the site of the lesion. 11 patients with focal chondral defects in the knee underwent TruFit plug implantation. Postoperative management entailed a period of 6 weeks of restricted weight bearing or restricted knee flexion according to implantation site. Radiological evaluation with MRI or CT arthrogram (or both) was conducted at various time points postoperatively according to clinical indication. Functional scoring with the Oxford knee score (OKS), Tegner activity scale and Lysholm score were completed.Background
Methods
There is mixed evidence in the literature regarding increasing age, ASA and BMI as risk factors for surgical site infection in orthopaedic surgery. To investigate the matter further, we examined 1055 wounds in 1008 patients in the Department of Trauma and Orthopaedic Surgery at University College London Hospital between 2000 and 2006. All patients with a minimum two-night stay were included. Data was collected by four designated research nurses. The age, height, weight and ASA status of each patient was recorded. All wounds were classified using ASEPSIS. This is a quantitative wound scoring method which is a summation of scores calculated from visual wound characteristics and the clinical consequences of infection. Our results showed a strong linear association between age and ASEPSIS scores. Single variable regression analysis showed a t value of 3.32 and p value of 0.001. A similar linear association was seen between ASA grading and ASEPSIS scores. Single variable regression analysis showed a t value of 2.75 and p value of 0.006. The association between BMI and ASEPSIS scores was markedly different from that seen with age and ASA. The graph was U-shaped with patients with a BMI of 25-30 having the lowest average ASEPSIS scores. Patients with a lower and a higher BMI had higher average ASEPSIS scores. Single variable regression analysis was not significant since the relationship between BMI and ASEPSIS scores is not linear. In conclusion, there are clearly defined patient groups who are at increased risk of developing a surgical site infection: older patients, patients with a higher ASA, and patients with both a low and high BMI. These patients should be targeted to reduce overall infection rates. This can be achieved by ensuring adequate antibiotic prophylaxis, having a low threshold to treat suspected infection and arranging regular follow-up.
On 7 July 2005, four bombs were detonated on the London transport system. Three of these bombs exploded almost simultaneously at 08:50h affecting the underground tube network at Aldgate, King's Cross and Edgware Road stations. The fourth bomb exploded at 09:47h on a double-decker bus in Tavistock Square. There were 54 deaths in total at the scenes and over 700 injured. 194 patients were brought to the Royal London Hospital. 167 were assessed in a designated minor injuries unit and discharged on the same day. 27 patients were admitted of whom 7 required ITU care, 1 died in theatre and 1 died post-operatively. The median Injurity Severity Score (ISS) in this group of patients was 6 (range 0-48) and the mean ISS was 12. The general pattern of injury in the critically ill patients was of mangled lower limbs and multiple, severely contaminated fragment wounds. Hepatitis B prophylaxis was administered to those patients with wounds contaminated by foreign biological material. 11 primary limb amputations were performed in 7 patients. 9 limb fasciotomies, 5 laparotomies and 1 sternotomy were carried out. 3 patients had blast lung injury. All patients who underwent primary amputations and debridement received further regular inspections in theatre. These inspections formed the majority of our theatre work. Under no circumstance was initial reconstructive surgery attempted. Delayed primary closure and split skin grafting of all wounds was completed by the end of the second week. There have been no sepsis-related deaths. Our experience at The Royal London has allowed us to revisit the principles of blast wound management in a peacetime setting. A number of lessons were learned regarding communication and resource allocation. A multi-disciplinary approach with the successful execution of a major incident plan is the key to managing an event of this magnitude.
Accurate placement of unicompartmental knee arthroplasty components is thought to be essential for the long-term survival and efficacy of the prosthesis. Computer navigation is being explored as a means of improving the accuracy of component position. There are few published studies comparing conventional and computer-navigated techniques using the same prosthesis. Twenty-two Allegretto [Zimmer] medial unicompartmental knee prostheses were placed in 18 patients using the AxiEM [Medtronic] computer-navigated system. The immediate post-operative AP and lateral radiographs were analysed and compared with an equivalent cohort of 30 prostheses in 29 patients with medial unicompartmental arthritis in whom the Allegretto was placed without the aid of computer navigation. All operations were performed by the senior author in a rural Queensland hospital. No cases were lost to follow-up. The data was not normally distributed. The mean, SD and variance of the data sets was calculated and significance tested with a 2-tailed Mann-Whitney U-test. Computer navigated tibial components were implanted with a mean of 2 degrees of varus compared with 1 degree of valgus with conventional navigation [p = 0.027]. Our target was 0–4 degrees of varus. Eighteen of the 20 computer-navigated cases, 90% fell within the recommended range [0–4 degrees of varus] compared with only 40%, 12 of the 30 conventionally-implanted cases. This is demonstrated by the greater range and variance of the conventional navigation data set. Posterior slope for the computer navigated components was 1 degree compared with 3 degrees for conventional navigation [0.010]; only 1 computed navigated component [5%] was implanted with anterior slope compared with 4 cases for conventional navigation [13%]. Measurements of femoral component flexion and position with respect to the tibial component were not significantly different but demonstrated greater variance for the conventionally navigated data set. Accurate component positioning improves efficacy and prosthesis survival for patients who meet the indications for unicompartmental surgery. However proponents acknowledge the weaknesses of conventional jigs for unicompartmental prostheses. In this study computer navigation has been shown to improve the accuracy of component placement.
We propose that ASEPSIS provides the most accurate and reproducible results and also provides more information with the grading of wound infection. The overall rate of orthopaedic wound infection using the ASEPSIS method is 3%. If all hospitals used this scoring method, more accurate comparisons of infection rates could be made.
Custom SNP pools were designed for the candidate regions at a density of 1 SNP/58Kb. DNA from 550 individuals (AD group) were genotyped using the Illumina platform. A total of 1536 SNP markers were attempted, of which 1324 were released; 519 SNPs were genotyped on 9q32-24 and 805 SNPs genotyped on 16p12-q22. The map was generated using NCBI dbSNP chromosome report on Build 34. Overall missing rate was 0.06%; the overall duplicate error rate was 0.05%. FIS was analysed both as a qualitative trait with an arbitrary threshold, and as a quantitative trait, or the degree of lateral curvature. Model independent sib-pair linkage analysis was performed on the subsets (SIBPAL, S. A. G. E. v4.5).
Chromosome 9: Multipoint model-independent qualitative analysis (threshold at ten degrees) did not result in any p values of <
0.05. When the threshold was set at 30 degrees, several regions with p values of <
0.005 were observed. One region spanned 10 Mb, and coincides with the region found to be most suggestive of linkage at the 0.05 level for the quantitative analysis which was 6 Mb in length. Chromosome 16: Multipoint model-independent qualitative analysis (threshold at ten degrees) resulted in a region spanning 23Mb with p values of <
0.05. The region included both regions adjacent to the centromere. When analysis was performed at a threshold of 30 degrees, the p values became more significant within a region of 30 Mb significant at the 0.05 level. The region best defined at a 0.01 level was located in an 8 Mb region on the q arm.
The Copeland Shoulder Arthroplasty is a cementless, pegged humeral head surface replacement. The design is based on the principle of minimal bone resection and has been in clinical use since 1986. The only published series to date, that of Levy and Copeland, reported results for 103 patients which were comparable to those obtained with stemmed implants. We report the outcome at our institution using the same prosthesis with a hydroxyapatite coating. 81 shoulders (74 patients) underwent resurfacing hemiarthroplasty through an anterior deltopectoral approach. Preoperative diagnoses were: osteoarthritis (39), rheumatoid arthritis (29), rotator cuff arthropathy (1), post-traumatic arthrosis (2). They were followed for an average 28 months. 10 were lost to follow-up (8 deaths). Constant scores improved from a mean preoperative figure of 15.7 to 54.0 (p<
0.01) at last follow-up. For rheumatoid arthritis and osteoarthritis the scores improved from 15.2 to 50.4 (p<
0.01) and 16.0 to 55.4 (p,<
0.01) respectively. There was a 13% complication rate with one case requiring revision for loosening to a stemmed implant. Most were cases requiring subsequent acromioplasty. In one case the glenoid rim was fractured during head dislocation. There was a low rate of perioprosthetic radiolucency (4.2%) which may relate to the hydroxyappatite coating within the shell of the prosthesis. Ipsilateral stemmed elbow replacement was performed in some cases without a double stress riser effect. Periprosthetic humeral neck fracture as managed non-operatively with uneventful union.
The purpose of this study was to look at the results of using the Copeland surface replacement in the treatment of arthritis of the shoulder. We report the results of 61 Type 3 Copeland surface replacements in 57 patients. Operations were performed in 33 cases of Rheumatoid Arthritis, 27 cases of Osteoarthritis and 1 case of posttraumatic arthritis. Hemiar-throplasty was performed via a Deltopectoral approach by the senior author in all cases. There were 38 females and 19 males with a minimum follow up of 1 year and a mean follow up of 26 months (range 12–65). Patients were scored pre and post operatively using the Constant score. Average pre-op score was 15.6 and post-operatively was 52.5. There was one case of loosening ( ? secondary to infection) requiring revision to a stemmed implant. Two patients required Sub-Acromial decompression for postoperative impingement. All patients considered their shoulder improved following this procedure. There was no evidence of radiolucency in any postoperative radiograph. Cementless surface replacement arthroplasty in our series show similar results to previously reported series of stemmed implants and to the published results available for this implant.