SL-PLUS MIA stem (Smith & Nephew Orthopaedics AG) is a modified implant of Zweymuller type SL-PLUS standard stem (Smith & Nephew Orthopaedics AG). We constructed finite element (FE) models and analysed equivalent stresses in the femur. In addition, we measured bone mineral density (BMD) in the femur by dual-energy X-ray absorptiometry (DEXA) after THA. The purpose of this study was to investigate the equivalent stress and to compare the results of the FE analyses with changes in BMD after THA. Twenty-one patients (18 women and 3 men) who underwent primary cementless THA with SL-PLUS MIA or SL-PLUS formed the basis of this study. Eleven patients received SL-PLUS MIA and ten patients received SL-PLUS. Zones were defined according to Gruen's system (zones 1∼7). Computed-tomography (CT) images of the femur were taken before and at 1 week after THA. FE models of the femur and prosthesis were obtained from CT data by Mechanical Finder (Research Center of Computational Mechanics Inc., Tokyo, Japan), software that creates FE models showing individual bone shape and density distribution. Equivalent stresses were analysed in zones 1 to 7 and compared to the DEXA data. FE studies revealed that there was no significant difference in equivalent stress between SL-PLUS MIA and SL-PLUS. BMD was maintained after THA in zones 3, 4, and 5, whereas BMD decreased in zones 2, 6, and 7. In zone 1, BMD decreased in SL-PLUS MIA stem group by 14%, while BMD was maintained in SL-PLUS standard stem.
In this study, we evaluated the labrum tear using radial sequence 3D Multiple Echo Recombined Gradient Echo (MERGE) MRI without arthrography based on modified Czerny's classification, comparing with actual arthroscopic findings. A total of 61 hips including 27 hips of femoroacetabular impingement (FAI), 19 hips of borderline development dysplasia of the hip (BDDH) and 15 hips of early stage osteoarthritis (OA) were enrolled this retrospective study. MRI findings evaluated in each three regions of interest; anterior region, anterolateral region, and lateral region. The cases with severe degeneration that is not concordant with any original Czerny's classification is defined as stage4. We compared MRI findings with arthroscopic findings and calculated the sensitivity, specificity, and likelihood ratio in terms of the existence of labrum tear. MRI findings revealed labrum tear more frequently in anterolateral than lateral (
Infection is one of the most serious complications of orthopedic surgery, particularly in implant-related procedures. Minimum inhibitory concentration (MIC) for identified bacteria is an important factor for successful antibiotic treatment. We investigated the MIC of antibiotics in Staphylococcus species from orthopedic infections, comparing with isolates from respiratory medicine. Staphylococcus species isolated in our laboratory from January 2013 to July 2016 were retrospectively reviewed. The MIC of vancomycin (VCM), arbekacin (ABK), teicoplanin (TEIC), linezolid (LZD), and rifampicin (RFP) was reviewed. Differences in the MIC of each antibiotic in orthopedic and respiratory samples were determined. A total of 259 isolates were evaluated (89 orthopedic, 170 respiratory). Staphylococcus aureus was the most commonly identified species (58%). In comparison with orthopedic samples, the number of isolates with a VCM MIC <0.5 μg/ml in methicillin sensitive staphylococcus aureus (MSSA) was significantly higher in respiratory isolates, while a MIC of 2 μg/ml was significantly lower (P = 0.0078). The proportion of isolates with a VCM MIC of 2 μg/ml in methicillin-resistant coagulase-negative staphylococci (MRCNS) was significantly higher in orthopedic isolates than that seen in respiratory isolates of methicillin-resistant staphylococcus aureus (MRSA; P < 0.001). When comparing MRCNS and other orthopedic Staphylococci, the rate of RFP MIC >2 μg/ml in MRCNS isolates was significantly higher (P = 0.0058). The MIC of VCM in Staphylococcus species from orthopedic infection was higher than that of respiratory samples, particularly in MRCNS from implant-related samples. MRCNS showed a significantly higher rate of resistance for RFP versus other orthopedic isolates.
Knee osteoarthritis (OA) is a major cause of ambulatory disabilities. Although total knee arthroplasty (TKA) has been reported as the most effective treatment for severe knee OA, quantitative evaluation of ambulatory function have not been well investigated. We hypothesized that better functional recovery would result in better patient satisfaction. The purpose of this study was to quantitatively evaluate ambulatory functional recovery and assess the influence on patient satisfaction after TKA. 90 patients (80 females and 10 males) were involved in this study. The mean age at TKA was 75.2 ± 5.8 years. Patients were subjected to 3 meters timed up and go test (TUG) to evaluate ambulatory function. TUG was performed at 6 time periods; before surgery, 2 weeks, 1, 3, 6 months, and 1 year after surgery. We also asked the patients to fill out the questionnaire of patient satisfaction category in the New Knee Society Score at 1 year after TKA. The sequential changes in TUG were analyzed using repeated measures ANOVA (p<0.05). The influences of each parameter (age, TUGs) on the patient satisfaction score were analyzed with simple regression analysis (p<0.05).Background
Material and Methods
Computed tomography (CT) based preoperative planning provides useful information for severe TKA and revision TKA cases, such as the amount of augmentation, length of stem extension and component alignment, to achieve correct alignment and joint line. In this study, we evaluated TKA alignment performed with CT preoperative planning. 7 primary TKAs for severe deformity and 3 revision TKAs were included. CT preoperative planning was performed with JIGEN (LEXI, Japan). Constrained condylar prosthesis (LCCK, Zimmer) were used in all case. For femoral component, axial alignment was decided by controlled IM rod insertion to femoral canal. Rotational alignment was decided according to anterior cortex that usually was not compromised. For tibial component, axial alignment was set to perpendicular to tibial mechanical axis. Coverage and joint line level were carefully decided. The amount of bone resection of bilateral distal and posterior femoral condyle and proximal tibia was measured, respectively. Stem extension length and offset were selected according to components position and canal filling. Amount of augmentation was also estimated bilateral distal and posterior femoral condyle, respectively. Postoperative component alignment was evaluated three-dimensionally with Knee-CAS (LEXI, Japan).Introduction
Materials and Methods
In measured resection (MR) technique it is sometimes not easy to equalize extension gap (EG) and flexion gap (FG) because the size of femoral component is generally determined only depending on the anteroposterior and mediolateral size of femoral condyle in MR technique. In order to equalize the EG and FG, femoral implant size should be determined so that the FG is similar to the EG. We developed the novel sizing technique of femoral component to equalize the EG and FG in MR technique. The purpose of this study was to examine the usefulness of this technique. Before surgery, the condylar twist angle: CTA (angle between the transepicondylar axis and the posterior condylar axis) was determined for individual knees by transepicondylar view (X ray) or CT. During surgery, after osteophyte was removed EG was made and measured. Knee was flexed in 90° and the specially made tensor which upper paddle has the medial inclination angle (same as the CTA) was inserted to FG before posterior femoral osteotomy. Then, the appropriate traction force was applied to FG. Under this condition, the correct rotational alignment of femur relative to tibia was obtained, and then, the size of femoral component could be determined so that the FG was similar to the EG by measuring the distance between tibial cut surface and posterior cut level of the respective size of femoral conponent. 23 knees that undergone TKA for end stage medial osteoarthritis were examined and the final EG and FG were measured. EG and FG were measured at the mediolateral center of the gap without any trial component.Background
Methods
Excessive acetabular coverage is the most common cause of pincer-type
femoroacetabular impingement. To date, an association between acetabular
over-coverage and genetic variations has not been studied. In this
study we investigated the association between single nucleotide
polymorphisms (SNPs) of paralogous Homeobox (HOX)9 genes and acetabular
coverage in Japanese individuals to identify a possible genetic
variation associated with acetabular over-coverage. We investigated 19 total SNPs in the four HOX9 paralogs, then
focused in detail on seven of those located in the 3’ untranslated
region of Objectives
Methods
Anterior cervical decompression and fusion (ACDF) is considered a standard surgical treatment to degenerative discogenic diseases. Lately, the question arises whether or not ACDF significantly influences the progression of adjacent disc degeneration (ADD). The etiology of ADD is obscure and it has not been fully understood whether ADD is a consequence of fusion or it represents the aging pathway of the degenerative cervical process, thus making it a controversial topic [1-3]. There have been several discussions about the possibility of ACDF altering biomechanical conditions at adjacent segments, therefore resulting in increased load and excessive motion [3,4]. The purpose of this study was to compare the cervical segmental motion pre- and post-ACDF using novel 3D analytical techniques. Nine patients (2F/7M, mean age: 54.1 years, range 36–76 y.o.) underwent ACDF due to symptomatic cervical degenerative discogenic disease. One-level ACDF was performed in 4 patients, whereas 2-level ACDF was done in five, using cylindrical titanium porous cage implants. Pre- and post (postoperative periods ranged from 11-months, 25 days to 12-months, 22 days, mean postoperative period: 12.09 months) surgery, dynamic-CT examinations were conducted in neutral, flexion and extension positions. Subject-based 3D CT models were created for segmental motion analysis (Fig. 1). Six-degrees-of-freedom 3D segmental movements were analyzed using a validated Volume-Merge methods (accuracy: 0.1 mm in translation, 0.2°in rotation) [5]. The segmental translation was evaluated by the segmental translations of gravity centers of endplates (Fig. 2). Disc-height distribution was measured using a custom-written Visual C++ routine implementing a lease-distance calculation algorithm. The mean translation distance was calculated for the each adjacent level (Fig. 2). Differences of segmental motions and mean disc height between pre- and post-surgery at each level were compared by the Wilcoxon signed rank test. Results were presented mean±SEM.Introduction
Methods
Discussion and conclusion: We improved the simple radiographic view in order to evaluate the TEA and PC line, and also the anterior trochlear line, for assessing the rotational alignment of the distal femur in total knee arthroplasty (TKA). We are able to measure and evaluate both angles and do double-checking the condylar twist angle and trochlear line angle. Our new radiographic technique is easy to measure the condylar twist angle, and the angle between AT line and clinical TEA (trochleo-epicondylar angle), simple and reliable, and may be an alternative method for the assessment of TEA of the femur in TKA as preoperative planning.