Vol. 105-B, Issue SUPP_8 | Pages 40 - 40
11 Apr 2023
Mahdi H Hardisty M Fullerton K Huang C Vachhani K Nam D Whyne C
Full Access

µCT images are commonly analysed to assess changes in bone density and architecture in preclinical murine models. Several platforms provide automated analysis of bone architecture parameters from volumetric regions of interest (ROI). However, segmentation of the regions of subchondral bone to create the volumetric ROIs remains a manual and time-consuming task. This study aimed to develop and evaluate automated pipelines for trabecular bone architecture analysis of mouse proximal tibia subchondral bone.

A segmented dataset involving 62 knees (healthy and arthritic) from 10-week male C57BL/6 mice were used to train a U-Net type architecture, with µCT scans (downsampled) input that output segmentation and bone volume density (BV/TV) of the subchondral trabecular bone. Segmentations were upsampled and used in tandem with the original scans (10µ) as input for architecture analysis along with the thresholded trabecular bone. The analysis considered the manually and U-Net segmented ROIs using two available pipelines: the ITKBoneMorphometry library and CTan (SKYSCAN). The analyses included: bone volume (BV), total volume (TV), BV/TV, trabecular number (TbN), trabecular thickness (TbTh), trabecular separation (TbSp), and bone surface density (BSBV).

There was good agreement for bone measures between the manual and U-Net pipelines utilizing ITK (R=0.88-0.98) and CTan (R=0.91-0.98). ITK and CTan showed good agreement for BV, TV, BV/TV, TbTh and BSBV (R=0.9-0.98). However, a limited agreement was seen between TbN (R=0.73) and TbSb (R=0.59) due to methodological differences in how spacing is evaluated.

This U-Net/ITK pipeline seamlessly automated both segmentation and quantification of the proximal tibia subchondral bone. This automated pipeline allows the analysis of large volumes of data, and its open-source nature may enable the standardization of stereologic analysis of trabecular bone across different research groups.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 51 - 51
1 Jul 2020
Vachhani K Whyne C Nam D Wong J Chou J Paul R
Full Access

Rotator cuff tears are the most common cause of shoulder disability, affecting 10% of the population under 60 and 40% of those aged 70 and above. Massive irreparable rotator cuff tears account for 30% of all tears and their management continues to be an orthopaedic challenge. Traditional surgical techniques, that is, tendon transfers are performed to restore shoulder motion, however, they result in varying outcomes of stability and complications. Superior capsular reconstruction (SCR) is a novel technique that has shown promise in restoring shoulder function, albeit in limited studies. To date, there has been no biomechanical comparison between these techniques. This study aims to compare three surgical techniques (SCR, latissimus dorsi tendon transfer and lower trapezius tendon transfer) for irreparable rotator cuff tears with respect to intact cuff control using a clinically relevant biomechanical outcome of rotational motion.

Eight fresh-frozen shoulder specimens with intact rotator cuffs were tested. After dissection of subcutaneous tissue and muscles, each specimen was mounted on a custom shoulder testing apparatus and physiologic loads were applied using a pulley setup. Under 2.2 Nm torque loading maximum internal and external rotation was measured at 0 and 60 degrees of glenohumeral abduction. Repeat testing was conducted after the creation of the cuff tear and subsequent to the three repair techniques. Repeated measures analysis with paired t-test comparisons using Sidak correction was performed to compare the rotational range of motion following each repair technique with respect to each specimen's intact control. P-values of 0.05 were considered significant.

At 0° abduction, internal rotation increased after the tear (intact: 39.6 ± 13.6° vs. tear: 80.5 ± 47.7°, p=0.019). Internal rotation was higher following SCR (52.7 ± 12.9°, intact - SCR 95% CI: −25.28°,-0.95°, p=0.034), trapezius transfer (74.2 ± 25.3°, intact – trapezius transfer: 95% CI: −71.1°, 1.81°, p=0.064), and latissimus transfer (83.5 ± 52.1°, intact – latissimus transfer: 95% CI: −118.3°, 30.5°, p=0.400) than in intact controls. However, internal rotation post SCR yielded the narrowest estimate range close to intact controls. At 60° abduction, internal rotation increased after the tear (intact: 38.7 ± 14.4° vs. tear: 49.5 ± 13°, p=0.005). Internal rotation post SCR did not differ significantly from intact controls (SCR: 49.3 ± 10.1°, intact – SCR: 95% CI: −28°, 6.91°, p=0.38). Trapezius transfer showed a trend toward significantly higher internal rotation (65.7 ± 21.1°, intact – trapezius transfer: 95% CI: −55.7°, 1.7°, p=0.067), while latissimus transfer yielded widely variable rotation angle (65.7 ± 38°, intact – latissimus transfer: 95% CI: −85.9°, 31.9°, p=0.68). There were no significant differences in external rotation for any technique at 0° or 60° abduction.

Preliminary evaluation in this cadaveric biomechanical study provides positive evidence in support of use of SCR as a less morbid surgical option than tendon transfers. The cadaveric nature of this study limits the understanding of the motion to post-operative timepoint and the results herein are relevant for otherwise normal shoulders only. Further clinical evaluation is warranted to understand the long-term outcomes related to shoulder function and stability post SCR.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 11 - 11
1 Nov 2016
Vachhani K Wang Y Nam D Whyne C
Full Access

Predictable fracture healing fails to occur in 5–10% of cases. This is particularly concerning among individuals with osteoporosis. With an increasing aging population, one in three women and one in five men above the age of 50 experience fragility fractures. As such, there is a critical need for an effective treatment option that could enhance fracture healing in osteoporotic bone. Lithium, the standard treatment for bipolar disorder, has been previously shown to improve fracture healing through modulation of the Wnt/beta-catenin pathway. We optimised the precise oral lithium administration parameters to improve mechanical strength and enhance healing of femoral fractures in healthy rats. A low dose of Lithium (20 mg/kg) administered seven days post fracture for a two week duration improved torsional strength by 46% at four weeks post fracture compared to non-treated animals. Application of lithium to enhance fracture healing in osteoporotic bone would have a significant healthcare impact and requires further study. Aim: To evaluate the efficacy of optimal lithium administration post fracture on quality of fracture healing in a rat osteoporotic model. Hypothesis: Lithium treatment in osteoporotic rats will improve the structural and mechanical properties of the healing bone despite the impaired nature of bone tissue.

Sprague Dawley female rats (∼350 g, age ∼3 months) were bilaterally ovariectomised and maintained for 3 months to establish the osteoporotic phenotype. A unilateral, closed mid-shaft femoral fracture was created using a weight-drop apparatus. At seven days post fracture, the treatment group received 20 mg/kg-wt lithium chloride via oral gavage daily for 14 days. The control group received an equivalent dose of saline. All animals were sacrificed at day 28 and the femurs harvested bilaterally. Treatment efficacy was evaluated based on torsional loading and stereologic analysis.

Lithium treatment positively impacted the healing femurs, with an average yield torque ∼1.25-fold higher than in the saline group (200±36 vs. 163±31 N-mm, p=0.15). Radiographically, the lithium-treated rats had a high level of restored periosteal continuity, larger bridging and intercortical callus at the fracture site. These hallmarks of healing were generally absent in the saline group. The Lithium group had significantly higher total volume (624±32 vs. 568±95 mm3), lower bone volume fraction (41±4 vs. 50±5%) and higher theoretical torsional rigidity (477±50 vs. 357±93 kN-mm2) compared to the saline group. Torsional strength and stereology values were similar for the contralateral femurs of the two groups.

Lithium was found to enhance fracture healing in osteoporotic bone under the dosing regimen optimised in healthy femora. This is promising data as treatment represents an easily translatable pharmacological intervention for fracture healing that may ultimately reduce the healthcare burden of osteoporotic fractures.