Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 128 - 128
1 May 2011
Binazzi R De Zerbi M Vaccari V Bondi A
Full Access

Press-fit cups have given excellent clinico-radiographical results. This is a retrospective clinico-radiographical study about the long term performance of pure Titanium cementless modular press-fit cups (FitekTM) having, on the outer surface, an oriented multilayer titanium mesh (SulmeshTM) with 65% porosity (average pore size=400–640 micron). The cup was implanted after underreaming the acetabulum by 2 mm. In the cup’s equatorial area there are two “fins” originary designed to improve rotational stability but actually representing two excellent primary mechanical stabilizers.

We have evaluated the first 100 consecutive cups implanted in 92 patients with an average FU of 9,7 years (range 9–11 years). All operations have ben performed by the two Senior Authors (PGM and RB). Regarding etiology, we had 43 Primary Arthritis, 37 Dysplastic Arthritis, 12 Osteonecrosis and 8 Post-traumatic Arthritis. results were evaluated with the Harris score. Radiographic evaluation was performed using AP and lateral x-rays pre-op. post-op and at the last follow-up.

We had 86 Excellent, 10 Good, 2 Fair and 2 Poor. The 2 Poor results were 2 aseptic loosenings of the stem

The Mann-Whitney nonparametric U test and the Kruskal-Wallis test showed that the survival rate of the 100 analyzed cups, after a mean follow-up of 9.7 years, was 100% (end point: revision for any cause)

Etiology was not statistically correlated with post-op score.

Nevertheless, dysplastic patients showed inferior results compared to arthritic patients in different parameters, as pain, limp, Range Of Motion (p < 0.05), putting socks and shoes (p < 0.05).

Our cups were intentionally implanted and radiographically appear in a fairly horizontal position (36.5° on average).

In 6 cases we could calculate an eccentricity of the metal heads proving bidimensional linear wear of the liner (average 0.265 mm / year). At the last follow-up we had 3 femoral osteolysis, while in the acetabular side radiolucent lines were present in 14 % of the cases, never progressive.

In no case we found a change of position of the cup.

FitekTM cementless cups gave excellent results at 10 years with complete stability and osteo-integration. Excellent primary mechanical stability was given by the rough surface (SulmeshTM) and by the two “fins” in the equatorial area.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 263 - 263
1 Mar 2004
Binazzi R Vaccari V Rossi R Marseglia G
Full Access

Aims: The purpose of this Paper is to review the preliminary results of a new tapered cementless revision stem, the T3, designed for cases of severe bone stock loss (Paprosky 2b, c and 3) usually representing a difficult challenge for the orthopaedic Surgeon. Methods: The T3 stem is made of Titanium alloy with a textured surface finish. The stem consists of a series of distal conical components to achieve a diaphyseal mechanical stability and 4 proximal bodies. The lateral offset is 42 mm and the cervicodiaphyseal angle is 138°. Between December 1998 and September 2001 we have implanted 22 T3 stems in 22 patients. Indications were severe bone loss in 13 cases, failed but stable cemented/cementless stems in 7 cases and peri-prosthetic fracture in 2. 14 patients were male and 8 female, the average age was 70 years. The average follow-up was 27 mo. In all cases a trans-femoral approach was used. The 7 cases with failed but stable stem showed pre-op a Paprosky 1 bone loss. However in these cases a trans-femoral approach was necessary to remove the stem and then a tapered stem became indispensable; 10 patients showed a Paprosky 2 bone loss (A=3 cases, B=3 cases, C=4 cases) and 5 a Paprosky 3. Post-op management was the same of a primary cementless case with full weight-bearing at 30 days. Results: The average Harris score was 40 points pre-op and 87 post-op. Good and Excellent results were 19(86%), 1 was Fair and 2 Poor (9%). Complications were 2 dislocations reduced conservatively and 1 paresis of Peroneal nerve recovered in 5 months. Bone reconstruction was excellent in 19 cases. 14 cases showed no subsidence and 8 < 5mm. Conclusion: T3 showed excellent preliminary results specially for what concerns bone reconstruction and lack of subsidence.