Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 33 - 33
4 Apr 2023
Pareatumbee P Yew A Koh J Zainul-Abidin S Howe T Tan M
Full Access

To quantify bone-nail fit in response to varying nail placements by entry point translation in straight antegrade humeral nailing using three-dimensional (3D) computational analysis

CT scans of ten cadaveric humeri were processed in 3D Slicer to obtain 3D models of the cortical and cancellous bone. The bone was divided into individual slices each consisting of 2% humeral length (L) with the centroid of each slice determined. To represent straight antegrade humeral nail, a rod consisting of two cylinders with diameters of 9.5mm and 8.5mm and length of 0.22L mm and 0.44L mm respectively joined at one end was modelled. The humeral head apex (surgical entry point) was translated by 1mm in both anterior-posterior and medio-lateral directions to generate eight entry points. Total nail protrusion surface area, maximum nail protrusion distance into cortical shell and top, middle, bottom deviation between nail and intramedullary cavity centre were investigated. Statistical analysis between the apex and translated entry points was conducted using paired t-test.

A posterior-lateral translation was considered as the optimal entry point with minimum protrusion in comparison to the anterior-medial translation experiencing twice the level of protrusion. Statistically significant differences in cortical protrusion were found in anterior-medial and posterior-lateral directions producing increased and decreased level of protrusion respectively compared to the apex. The bottom anterior-posterior deviation distance appeared to be a key predictor of cortical breach with the distal nail being more susceptible. Furthermore, nails with anterior translation generated higher anterior-posterior deviation (>4mm) compared to posterior translation (<3mm).

Aside from slight posterolateral translation of the entry point from the apex, inclusion of a distal posterior-lateral bend into current straight nail design could improve nail fitting within the curved humeral bone, potentially improving distal working length within the flat and narrow medullary canal of the distal humeral shaft.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 32 - 32
4 Apr 2023
Pareatumbee P Yew A Meng Chou S Koh J Zainul-Abidin S Howe T Tan M
Full Access

To analyse bone stresses in humerus-megaprosthesis construct in response to axial loading under varying implant lengths in proximal humeral replacement following tumour excision.

CT scans of 10 cadaveric humeri were processed in 3D Slicer to obtain three-dimensional (3D) models of the cortical and cancellous bone. Megaprostheses of varying body lengths (L) were modelled in FreeCAD to obtain the 3D geometry. Four FE models: group A consisting of intact bone; groups B (L=40mm), C (L=100mm) and D (L=120mm) comprising of humerus-megaprosthesis constructs were created. Isotropic linear elastic behaviour was assigned for all materials. A tensile load of 200N was applied to the elbow joint surface with the glenohumeral joint fixed with fully bonded contact interfaces. Static analysis was performed in Abaqus. The bone was divided at every 5% bone length beginning distally. Statistical analysis was performed on maximum von Mises stresses in cortical and cancellous bone across each slice using one-way ANOVA (0-45% bone length) and paired t-tests (45-70% bone length). To quantify extent of stress shielding, average percentage change in stress from intact bone was also computed.

Maximum stress was seen to occur distally and anteriorly above the coronoid fossa. Results indicated statistically significant differences between intact state and shorter megaprostheses relative to longer megaprostheses and proximally between intact and implanted bones. Varying levels of stress shielding were recorded across multiple slices for all megaprosthesis lengths. The degree of stress shielding increased with implant lengthening being 2-4 times in C and D compared to B.

Axial loading of the humerus can occur with direct loading on outstretched upper limbs or indirectly through the elbow. Resultant stress shielding effect predicted in longer megaprosthesis models may become clinically relevant in repetitive axial loading during activities of daily living. It is recommended to use shorter megaprosthesis to prevent failure.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 35 - 35
4 Apr 2023
Teo B Yew A Tan M Chou S Lie D
Full Access

This study aims to compare the biomechanical properties of the “Double Lasso-Loop” suture anchor (DLSA) technique with the commonly performed interference screw (IS) technique in an ex vivo ovine model.

Fourteen fresh sheep shoulder specimens were used in this study. Dissection was performed leaving only the biceps muscle attached to the humerus and proximal radius before sharply incised to simulate long head of biceps tendon (LHBT) tear. Repair of the LHBT tear was performed on all specimens using either DSLA or IS technique. Cyclical loading of 500 cycles followed by load to failure was performed on all specimens. Tendon displacement due to the cyclical loading at every 100 cycles as well as the maximum load at failure were recorded and analysed. Stiffness was also calculated from the load displacement graph during load to failure testing.

No statistically significant difference in tendon displacement was observed from 200 to 500 cycles. Statistically significant higher stiffness was observed in IS when compared with DSLA (P = .005). Similarly, IS demonstrated significantly higher ultimate failure load as compared with DSLA (P = .001). Modes of failure observed for DSLA was mostly due to suture failure (7/8) and anchor pull-out (1/8) while IS resulted in mostly LHBT (4/6) or biceps (2/6) tears. DSLA failure load were compared with previous studies and similar results were noted.

After cyclical loading, tendon displacement in DLSA technique was not significantly different from IS technique. Despite the higher failure loads associated with IS techniques in the present study, absolute peak load characteristics of DLSA were similar to previous studies. Hence, DLSA technique can be considered as a suitable alternative to IS fixation for biceps tenodesis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 79 - 79
1 Jul 2020
Padki A Lim W Cheng D Howe T Koh J Png MA Tan M
Full Access

Multiple studies have shown that the symptomatology of knee osteoarthritis weakly correlate to radiographic severity of disease. Current literature however does not have much in the way of comparing functional outcomes of those with OA knees with radiographic severity. Our objective was to compare radiographic measurements of OA knees with self-reported functional outcomes and determine if radiographic severity of OA knees correlated with loss of functional ability.

A retrospective review of prospectively collected registry data of 305 patients with osteoarthritis of the knee was collected. The patient's x-rays were reviewed, and radiographic measurements were taken to include medial, lateral and patellofemoral joint space distance measured in millimetres. The Kellgren and Lawrence, and Ahlback classifications of radiographic knee OA were computed. These were correlated with severity of functional limitations was measured using the SF36, Knee society score (KSS) and Oxford knee scores.

Statistical analysis were conducted with SPSS V22.0 statistical software. Demographic characteristics and functional assessments were analysed using one way ANOVA test. Post-hoc test using Tukey HSD and effect size (partial-eta squared η2) was performed if one-way ANOVA was found to be statistically significant. A p-value of 0.05 or less was considered statistically significant.

Pre-operative patient demographics are shown in table 1. Patients in with Grade 2 osteoarthritis were significantly younger than Grade 4 patients (post-hoc p=0.003). There were no statistically significant differences in age between the other Grades, and there were no differences in BMI or gender or operative site between all grades.

There were significant differences in KSS Function scores between Grade 2 and Grade 3 patients (post-hoc p=0.017) and Grade 2 and 4 patients (post-hoc p < 0 .001). Statistically significant differences were also found between Grade 1 and Grade 4 patients for the KSS Knee score (post-hoc p=0.016). There were significant differences in Oxford knee score (post-hoc p=0.026) and SF- Physical Function (post-hoc p < 0 .001) between Grade 2 and Grade 4 patients too.

The effect size η2 for KSS Function, KSS Knee and Oxford knee score was 0.05, 0.06 and 0.33 respectively. When comparing the loss of joint space with the functional scores, there were no statistically significant correlations. Our study show that the radiological severity of knee osteoarthritis based on the two scoring methods was able to correlate with worsening functional scores. Most notably, the differences in KSS function scores correlated strongly between Grade 2 and Grade 3 patients. Of note, there was no correlation between the loss of joint space and the severity of functional limitations across any of the scoring systems. Our study showed that although both the Kellgren and Lawrence and Ahlback radiological grading of Osteoarthritis were able to correlate with worsening functional scores, this was not due to loss of joint space alone and further studies need to be conducted on the other contributors to the scoring system such as osteophytes and subchondral sclerosis.

Our study show that the radiological severity of knee osteoarthritis based on the two scoring methods was able to correlate with worsening functional scores. Most notably, the differences in KSS function scores correlated strongly between Grade 2 and Grade 3 patients. Of note, there was no correlation between the loss of joint space and the severity of functional limitations across any of the scoring systems. Our study showed that although both the Kellgren and Lawrence and Ahlback radiological grading of Osteoarthritis were able to correlate with worsening functional scores, this was not due to loss of joint space alone and further studies need to be conducted on the other contributors to the scoring system such as osteophytes and subchondral sclerosis.

For any figures or tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 143 - 143
1 May 2016
Puah K Yeo W Tan M
Full Access

Aim

Computer-navigated total knee arthroplasty has been shown to improve the outcome in outliers with consistent results. The aim of this study is to evaluate the clinical and radiographic outcomes of computer-navigated knee arthroplasty with respect to deformity and body mass index (BMI).

Materials and Methods

Data was prospectively collected for 117 consecutive patients undergoing primary computer-navigated total knee arthroplasty using Ci Brainlab system with J&J PFC PS implants by a single surgeon utilising a tibia cut first, gap-balancing technique. Pre-operative and post-operative long-leg films, weight-bearing, films were taken and the long-axis was measured by a single observer. Intra-operative computer navigation long-axis values were stored as screenshots intra-operatively after registration and after implant was cemented. BMI, range of motion (ROM), SF 36 and Oxford knee scores were recorded both before surgery and on follow-up. Minimum 2-year follow-up. Eight patients were lost to follow-up and 8 had incomplete 2 year data. Data was analysed using the Chi-squared test for categorical variables and the t-test for continuous variables.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 30 - 30
1 Oct 2012
Ee G Pang H Chong H Tan M Lo N Chin P Chia S Yeo S
Full Access

Restoration of the native joint line in total knee arthroplasty is important in restoring ligamentous balance and normal knee kinematics. Failure to achieve this could lead to reduced range of motion, patellofemoral maltracking and suboptimal outcomes. The purpose of this study was to analyse the clinical and functional outcome of patients who demonstrated joint line changes after computer-assisted (CAS) total knee arthroplasty (TKA).

A prospective study was conducted for 168 patients (168 knees) who underwent CAS TKA by two surgeons at a single institution with an average follow-up of two years. The final change in joint line was calculated from the verified tibial resection, distal and posterior femoral cuts. Group A patients had joint line changes of less than 4mm and Group B patients had joint line changes of more than 4mm. Postoperative Oxford scores, Knee scores, Function scores and SF-36 scores were obtained at six months, one year and two years post-TKA. The final range of motion and the mechanical alignment were documented.

There was significant linear correlation between joint line changes and Oxford scores (p = 0.05) and Function scores (p = 0.05) at six months and Oxford scores alone at two years with increasing joint line changes having poorer outcome scores. Group A compared to Group B patients have better outcomes in terms of Oxford scores (mean 20 vs 27, p = 0.0003), Function scores (mean 69 vs 59, p = 0.03), SF-1 (mean 63 vs 50, p = 0.03), SF-2 (mean 66 vs 43, p = 0.05), SF-5 (mean 75 vs 63, p = 0.04), SF-6 (mean 84 vs 59, p = 0.003), SF-7 (mean 96 vs 83, p = 0.02), SF-8 (mean 84 vs 73, p = 0.006) and total SF-36 scores (mean 603 vs 487, P = 0.003), at six months, and Oxford scores (mean 18 vs 23, p = 0.0007) at two years.

In this study, CAS is a useful intra-operative tool for assessing the final joint line in TKA. Outliers in joint line changes of ≥ 4 mm are associated with poorer clinical outcome scores.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 168 - 168
1 May 2011
Molyneux S Tan M Mcqueen M
Full Access

Introduction: We present the world’s largest current series of open distal radial fractures (ODRF), aiming to describe the epidemiology and outcomes of these injuries.

Methods: Patients with ODRF treated at the Edinburgh Orthopaedic Trauma unit between 1990 and 2009 were identified from computer records. All patients aged over 13 with juxta-articular and metaphyseal fractures were included – diaphyseal injuries were excluded. The following information was retrieved from notes and radiographs: patient demographics; co-morbidities; mechanism of injury; AO classification; other injuries; time to A& E treatment; time until surgery; antibiotic use; Gustillo and Anderson (GA) grade; surgical treatment; complications; further surgery; functional outcome.

Results: 201 patients were included. The average age was 65.5 years, 75% were female. 69% resulted from simple falls, 15% falls from height, 6% sporting injuries and 9% from road traffic accidents. 73 % were GA-1, 26% were GA-2, 1% GA-3. The commonest fracture pattern was AO 23-C2. 41% underwent definitive debridement within 6 hours, 46% in 6 to 24 hours, 13% waited longer. 30% were treated by ORIF, 38% with non-bridging fixator, 29% by bridging fixator and 3% by MUA and plaster. 43% of wounds were closed primarily, 47% were left open, 8% required delayed closure, 2% required skin grafting. Follow-up averaged 16.5 weeks. 14% suffered superficial infections, 1.3% suffered deep infection. Predictors of infection included primary closure and the use of an external fixator. Functional outcome was variable.

Discussion: Most open distal radial fractures occur in elderly women after a simple fall. Serious infection rates are low.