Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 45 - 45
1 Feb 2016
Fukunishi S Fujihara Y Takeda Y Yoshiya S
Full Access

Introduction

In recent literatures dealing with optimisation of prosthetic alignment in total hip arthroplasty (THA), the concept of combined anteversion (CA), sum of acetabular anteversion (AV) and femoral antetorsion (AT), has been addressed. We have been using an image-free THA navigation system?OrthoPilot THAPro?to achieve improved overall alignment with both stem and cup. In the use of this system, we have used the stem-first procedure so-called CA technique. In this technique, the femur was prepared first with the target angle corresponding to the native femoral AT and the cup AV was decided considering CA calculated with the formula of Widmer (37.3°= cup AV + 0.7 stem AT). The purpose of this study was to evaluate the accuracy of CA by using CA technique with image-free navigated THA.

Methods

Fifty hips underwent primary THA using OrthoPilot THApro with CA technique. In CA technique, the femur was prepared first and the target angle of AT value was basically determined by for the individual native femoral AT angle. After the femur was prepared, the cup AV was decided based on the formula of Widmer. All included patients underwent postoperative CT examination, and the prosthetic alignment was assessed using the 3D-Template system (Zed Hip, LEXI).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 42 - 42
1 Feb 2016
Fujihara Y Fukunishi S Takeda Y Yoshiya S
Full Access

Purpose

Implant positioning is one of the critical factors influencing the postoperative outcome in total hip arthroplasty (THA). Conventional (manual) intraoperative stem adjustment may result in variability and inaccuracy of stem antetorsion (AT). Since March 2013, we have measured stem antetorsion with CT free Navigation system (OrthoPilot Navigation System THA Pro Ver4.2, B/Braun Aesculap Germany: Navi). We have developed a simple instrument, the Gravity-guide (G-guide), for intraoperative assessment and adjustment of stem AT. We evaluated the accuracy and effectiveness of G-guide and navigation software as referenced to postoperative CT evaluation with 3D template system (Zed hip, LEXI, Japan).

Method

Between March 2013 and December 2014, 50 patients underwent primary THA were evaluated. Surgeries were performed with routine techniques with a modified Hardinge approach with the patient at a lateral decubitus position in all cases. The G-guide consists of two parts: one attached to the lower leg and the other attached to the handle of the rasp. During surgery, AT value was determined with navigation at the time of final rasping of the femur. Additionally, the G-guide was utilised at the time of final rasp insertion. In intraoperative AT assessment using this instrument, a correction was required considering the discrepancy between the perpendicular to the posterior condylar axis and the longitudinal axis of the lower leg. The angle of discrepancy between posterior condylar line and femoral trans-epicondyler axis needs to be taken into consideration. Therefore, correction by the angle between the trans-epicondylar and posterior condylar lines (correction angle) was required for each patient when the intraoperative AT as measured by the G-guide. Therefore, the correction angle should be added to the AT value obtained from the G-guide for comparison with postoperative value measured with Zed Hip.