Vol. 88-B, Issue SUPP_I | Pages 101 - 101
1 Mar 2006
Langdown A Pandit H Price A Dodd CAF Murray D Svoerd Gibbons C
Full Access

Introduction This study assesses the outcome of medial unicompartmental knee arthroplasty (UKA) using the Oxford prosthesis for end-stage focal spontaneous osteonecrosis of the knee (SONK, Ahlback grades III & IV).

Methods A total of 29 knees (27 patients) with SONK were assessed using the Oxford Knee Score. Twenty-six had osteonecrosis of the medial femoral condyle; 3 had osteonecrosis of the medial tibial plateau. This group was compared to a similar group who had undergone Oxford Medial UKA for primary osteoarthritis. Patients were matched for age, sex and time since operation.

Results Mean length of follow-up was 5.2 years (range 1–13 years). There were no implant failures in either group, but there was one death 9 months post-arthroplasty from unrelated causes in the group with osteonecrosis. The mean Oxford Knee Score (SD) in the group with osteonecrosis was 37.8 (7.6) and 40.0 (6.6) in the group with osteoarthritis. There was no significant difference between the two groups using Student’s t-test (p=0.29).

Interpretation Use of the Oxford Medial UKA for focal spontaneous osteonecrosis of the knee is reliable in the short to medium term, and gives similar results to when used for patients with primary osteoarthritis.