Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 138 - 138
11 Apr 2023
Cheon S Suh D Moon J Park J
Full Access

Surgical debridement for medial epicondylitis (ME) is indicated for patients with refractory ME. The clinical efficacy of simple debridement has not been studied sufficiently. Moreover, authors experienced surgical outcome of ME was not as good as lateral epicondylitis. In this regard, authors have combined the atelocollagen injection in the debridement surgery of ME. The purpose of study was to compare clinical outcomes between simple debridement and debridement combined with atelocollagen injection in the ME.

Twenty-five patients with refractory ME and underwent surgical debridement were included in the study. Group A (n=13) was treated with isolated debridement surgery, and group B (n=12) was treated with debridement combined with 1.0 mL of type I atelocollagen. Pain and functional improvements were assessed using visual analogue scale, Mayo Elbow Performance Score (MEPS) and quick Disabilities of the Arm, Shoulder and Hand (DASH) scale respectively before surgery, at 3, 6 months after surgery and at the final follow-up.

Demographic data did not show significant difference between two groups before surgical procedures. Both groups showed improvement in pain and functional score postoperatively. However, at the 3 months after surgery, group B showed significantly better improvement as compared to group A(VAS 3.1 / 2.0, MEPS 71/82 qDASH 29/23). At the 6 months after surgery and final follow-up, both groups did not show any difference.

Surgical debridement combined with atelocollagen is effective treatment option in refractory ME and showed better short-term outcomes compared to isolated surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 139 - 139
11 Apr 2023
Jeong S Suh D Park J Moon J
Full Access

Olecranon plates used for the internal fixation of complex olecranon fractures are applied directly over the triceps tendon on the posterior aspect of the olecranon. The aim of the study is to describe the relationship of the plates and screws to the triceps tendon at the level of the olecranon.

Eight cadaveric elbows were used. Dimensions of the triceps tendon at the insertion and 1cm proximal were measured. A long or a short olecranon plate was then applied over the olecranon and the most proximal screw applied. The length of the plate impinging on the tendon and the level of the screw tract on the tendon and bone were measured.

The mean olecranon height was 24.3cm (22.4-26.9cm) with a tip-to-tendon distance of 14.5cm (11.9-16.2cm). The triceps tendon footprint averaged 13.3cm (11.7-14.9cm) and 8.8cm (7.6-10.2cm) in width and length, respectively. The mean width of the central tendon 1 cm proximal to the footprint was 6.8 cm. The long olecranon plate overlay over more movable tendon length than did the short plate and consequently the superior screw pierced the triceps tendon more proximally with the long plate. Using the Mann-Whitney U test, the differences were significant.

The long olecranon plates encroach on more triceps tendon than short plates. This may be an important consideration for olecranon fractures with regards implant loosening or triceps tendon injury.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 29 - 29
1 Apr 2018
Kim S Han S Rhyu K Yoo J Oh K Lim S Suh D Yoo J Lee K
Full Access

Introduction

In recent years, there has been an increase in hip joint replacement surgery using short bone-preserving femoral stem. However, there are very limited data on postoperative periprosthetic fractures after cementless fixation of these stem although the periprosthetic fracture is becoming a major concern following hip replacement surgery. The purpose of this study is to determine incidence of postoperative periprosthetic femoral fractures following hip arthroplasty using bone preserving short stem in a large multi-center series.

Materials & Methods

We retrospectively reviewed 897 patients (1089 hips) who underwent primary total hip arthroplasty (THA) or bipolar hemiarthroplasty (BHA) during the same interval (2011–2016) in which any other cementless, short bone-preserving femoral stem was used at 7 institutions. During the study, 1008 THAs were performed and 81 BHAs were performed using 4 different short femoral prostheses. Average age was 57.4 years (range, 18 – 97 years) with male ratio of 49.7% (541/1089). Postoperative mean follow-up period was 1.9 years (range, 0.2 – 7.9 years).


Bone & Joint Research
Vol. 7, Issue 1 | Pages 20 - 27
1 Jan 2018
Kang K Son J Suh D Kwon SK Kwon O Koh Y

Objectives

Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA.

Methods

The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.


Bone & Joint Research
Vol. 6, Issue 11 | Pages 623 - 630
1 Nov 2017
Suh D Kang K Son J Kwon O Baek C Koh Y

Objectives

Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions.

Methods

Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 37 - 37
1 May 2016
Shon W Suh D Han S Yun H Kumar P
Full Access

Introduction

The purpose of this study was to identify the factors contributing to the development and progression of periacetabular osteolytic lesions and to identify which of these lesions can progress at an early stage following THA using repeated computed tomography scans. We also evaluated the accuracy of radiographs in assessing periacetabular osteolysis after THA with uncemented acetabular components and compared it with results of CT analysis.

Methods

CT scans were done in ninety-seven patients (118 hips) who had undergone primary THA between 1996 and 2004 at our hospital at a minimum of two-years postoperatively, from April to August 2006. All the CT images were acquired using high resolution multi-detector row CT (MDCT). The mean age of the patients at the time of surgery was 46.2 years (range, 21–65 years). The mean follow-up at the time of obtaining CT scan was 82.1 months (range, 18–234 months). The second CT scans were obtained in sixty three hips of 49 patients (36 males and 13 females) in 2009. The mean of patient's age was 52.7 years (range, 30 to 76 years). At the time of initial CT scan, the mean duration of implantation was 76.9 months (range, 17–156 months). The volume of periacetabular osteolysis was measured using Rapidia 3D software version. Linear wear of the PE was measured in digitalized radiographs obtained within 3 months of the surgery.