Efficacious antibiotic treatment is crucial for managing and preventing orthopedic infections due to their complexity and associated risk of treatment failure. Previous reviews on antibiotic target tissue concentrations have primarily focused on static measurements, which may not accurately reflect the dynamic pharmacokinetic/pharmacodynamic (PK/PD) changes encountered in clinical settings. This review aimed to summarize the current literature on antibiotic distribution in orthopedically relevant tissues and settings using dynamic sampling methods. In accordance with PRISMA guidelines, a literature search was conducted with a scientific librarian's assistance. PubMed and Embase databases were systematically searched using relevant MeSH terms, entries, and keywords. English-published studies between 2004 and 2023 involving systemic antibiotic administration and dynamic measurements were included. 4467 titles were identified. After title and abstract screening, 77 eligible studies remained.Aim
Method
Antibiotic prophylaxis is central in preventing postoperative spine infections, yet knowledge of clinical spine tissue antibiotic concentrations remains limited. Pooled postoperative spine infection rates are constant (approximately 3%), resulting in severe patient morbidity, mortality, and prolonged hospitalization. Current antibiotic dosing regimens often involve fixed doses based on empirical knowledge, surrogate measures (plasma samples), non-clinical evidence (experimental models), and inferior methodology (tissue specimens). Therefore, personalized antibiotic dosing may be the future of antibiotic prophylaxis to prevent postoperative infections, especially implant infections. The aim was to continuously evaluate intra- and postoperative cefuroxime target spine tissue concentrations in long-lasting spine surgery after personalized dosing by repeated weight-dosed intravenous administrations. Twenty patients (15 female, 5 male) scheduled for long-lasting spine deformity surgery with hypotensive anaesthesia were included; median age (range): 17.5 years (12-74), mean BMI (range): 22.2 (16.2-37.7), and mean surgery time (range): 4h 49min (3h 57min-6h 9min). Weight-dosed cefuroxime (20 mg/kg) was administered intravenously to all patients on average 25 min before incision and repeated after 4 hours. Microdialysis catheters were placed for sampling of cefuroxime concentrations in vertebral bone (only intraoperative sampling), paravertebral muscle, and subcutaneous tissue as soon as possible after surgery start. Upon wound closure, two additional catheters were placed in the profound and superficial part of the wound. Microdialysis and plasma samples were obtained continuously intra- and postoperative for up to 12 hours. The primary endpoint was (based on cefuroxime time-dependent efficacy) the time with cefuroxime concentrations above the clinical breakpoint minimal inhibitory concentration for patients’ individual surgery time, first dosing interval (0-4 hours), second dosing interval (4-12 hours).Aim
Method
Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty. In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion.Introduction
Method
Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.Aims
Methods
The β-lactam penicillin is often used in the treatment of soft tissue infections and osteomyelitis caused by penicillin susceptible 12 female pigs (75kg) were assigned to standard clinical regimens of either three doses of IV penicillin G (1.2g) or oral penicillin V (0.8g) every 6h over 18h. Microdialysis catheters were placed for sampling in tibial cancellous bone and adjacent subcutaneous tissue. Data was collected in the first dosing interval (0–6h; prophylactic situation) and the third dosing interval (12–18h; assumed steady state). Plasma samples were collected for reference. MIC targets of 0.125μg/mL (Aim
Method
Implant-associated osteomyelitis is one of the most feared complications following orthopedic surgery. Although the risk is low it is crucial to achieve adequate antibiotic concentrations proximate to the implant for a sufficient amount of time to protect the implant surface and ensure tissue integration. The aim of this study was to assess steady-state piperacillin concentrations in the proximity of an orthopedic implant inserted in cancellous bone. Six female pigs received an intravenous bolus infusion of 4 g/0.5 g piperacillin/tazobactam over 30 min every 6 h. Steady state was assumed achieved in the third dosing interval (12–18 h). Microdialysis catheters were placed in a cannulated screw in the proximal tibial cancellous bone, in cancellous bone next to the screw, and in cancellous bone on the contralateral tibia. Dialysates were collected from time 12 to 18 h and plasma samples were collected as reference.Background and aim
Method
The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems. In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up.Aims
Methods
In an attempt to alleviate symptoms of the disease, patients with knee osteoarthrosis (KOA) frequently alter their gait patterns. Understanding the underlying pathomechanics and identifying KOA phenotypes is essential for improving treatments. We aimed to investigate altered kinematics in patients with KOA to identify subgroups. Sixty-six patients with symptomatic KOA scheduled for total knee arthroplasty and 12 age-matched healthy volunteers with asymptomatic knees were included. We used k-means to separate the patients based on dynamic radiostereometric assessed knee kinematics. Ligament lesions, KOA score, and clinical outcome were assessed by magnetic resonance imaging, radiographs, and patient reported outcome measures, respectively. We identified four clusters that were supported by clinical characteristics. Compared with the healthy group; The flexion group (n=20): revealed increased flexion, greater adduction, and joint narrowing and consisted primarily of patients with medial KOA. The abduction group (n=17): revealed greater abduction, joint narrowing and included primarily patients with lateral KOA. The anterior draw group (n=10): revealed greater anterior draw, external tibial rotation, lateral tibial shift, adduction, and joint narrowing. This group was composed of patients with medial KOA, some degree of anterior cruciate ligament lesion and the greatest KOA score. The external rotation group (n=19): revealed greater external tibial rotation, lateral tibial shift, adduction, and joint narrowing while no anterior draw was observed. This group included primarily patients with medial collateral and posterior cruciate ligament lesions. Patients with KOA can, based on their gait patterns, be classified into four subgroups, which relate to their clinical characteristics. The findings add to our understanding of associations between disease pathology characteristics in the knee and the pathomechanics in patients with KOA. A next step is to investigate if patients in the pathomechanic clusters have different outcomes following total knee arthroplasty.
The Pivot-shift test is a clinical test for knee instability for patinets with Anterior cruciate ligament (ACL), however the test has low inter-observer reliability. Dynamic radiostereometry (dRSA) imaging is a highly precise method for objective evaluation of joint kinematics. The purpose of the study was to quantify precise knee kinematics during Pivot-shift test by use of the non-invasive dynamic RSA imaging. Eight human donor legs with hemipelvis were evaluated. Ligament lesion intervention of the ACL was performed during arthroscopy and anterolateral ligament (ALL) section was performed as a capsular incision. Pivot-shift test examination was recorded with dRSA on ligament intact knees, ACL-deficient knees and ACL+ALL-deficient knees. A Pivot-shift pattern was identifyable after ligament lesion as a change in tibial posterior drawer velocity from 7.8 mm/s in ligament intact knees, to 30.4 mm/s after ACL lesion, to 35.1 mm/s after combined ACL-ALL lesion. The anterior-posterior drawer excursion increased from 2.8 mm in ligament intact knees, to 7.2 mm after ACL lesion, to 7.6 mm after combined lesion. Furthermore a change in tibial rotation was found, with increasing external rotation at the end of the pivot-shift motion going from intact to ACL+ALL-deficient knees This experimental study demonstrates the feasibility of RSA to objectively quantify the kinematic instability patterns of the knee during the Pivot-shift test. The dynamic parameters found through RSA displayed the kinematic changes from ACL to combined ACL-ALL ligament lesion.
Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation. Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01). The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.
This study investigated if co-administration of rifampicin with moxifloxacin led to a decrease in moxifloxacin concentrations in relevant tissues in a porcine model of implant-associated osteomyelitis caused 15 female pigs received a stainless-steel implant in the right proximal tibia and were randomized into two groups. Infection was introduced by inoculating the implant with Aim
Method
Surgical site infection following spine surgery is associated with increased morbidity, mortality and increased cost for the health care system. The reported pooled incidence is 3%. Perioperative antibiotic prophylaxis is a key factor in lowering the risk of acquiring an infection. Previous studies have assessed perioperative cefuroxime concentrations in the anterior column of the cervical spine with an anterior surgical approach. However, the majority of surgeries are performed in the posterior column and often involve the lumbar spine. Accordingly, the objective was to compare the perioperative tissue concentrations of cefuroxime in the anterior and posterior column of the same lumbar vertebra using microdialysis in an experimental porcine model. The lumbar vertebral column was exposed in 8 female pigs. Microdialysis catheters were placed for sampling in the anterior column (vertebral body) and posterior column (posterior arch) within the same vertebra (L5). Cefuroxime (1.5 g) was administered intravenously over 10 min. Microdialysates and plasma samples were continuously obtained over 8 hours. Cefuroxime concentrations were quantified by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry. Microdialysis is a catheter-based pharmacokinetic tool, that allows dynamic sampling of unbound and pharmacologic active fraction of drugs e.g., cefuroxime. The primary endpoint was the time with cefuroxime above the clinical breakpoint minimal inhibitory concentration (T>MIC) for Background
Method
Deadspace is the tissue and bony defect in a surgical wound after closure. This space is presumably poorly perfused favouring bacterial proliferation and biofilm formation. In arthroplasty surgery, an obligate deadspace surrounding the prosthesis is introduced and deadspace management, in combination with obtaining therapeutic prophylactic antibiotic concentrations, is important for limiting the risk of acquiring a periprosthetic joint infection (PJI). This study aimed to investigate cefuroxime distribution to an orthopaedic surgical deadspace in comparison with plasma and bone concentrations during two dosing intervals (8 h × 2). In a setup imitating shoulder arthroplasty surgery, but without insertion of a prosthesis, microdialysis catheters were placed for cefuroxime sampling in a deadspace in the glenohumeral joint and in cancellous bone of the scapular neck in eighteen pigs. Blood samples were collected from a central venous catheter as a reference. Cefuroxime was administered according to weight (20 mg/kg). The primary endpoint was time above the cefuroxime minimal inhibitory concentration of the free fraction of cefuroxime for Staphylococcus aureus (Aim
Method
Prompt and sufficient broad spectrum empirical antibiotic treatment is key to prevent infection following open tibial fractures. Succeeding co-administration, we dynamically assessed the time for which vancomycin and meropenem concentrations were above relevant epidemiological cut-off minimal inhibitory concentrations (T>MIC) in tibial compartments for the bacteria most frequently encountered in open fractures. Low and high MIC-targets were applied: 1 and 4 µg/mL for vancomycin and 0.125 and 2 µg/mL for meropenem. 8 pigs received a single dose of 1000 mg vancomycin and 1000 mg meropenem simultaneously over 100 min and 10 min, respectively. Microdialysis catheters were placed for sampling over 8 h in tibial cancellous bone, cortical bone, and adjacent subcutaneous adipose tissue. Venous blood samples were collected as references.Aim
Materials and methods
Prompt and sufficient broad-spectrum empirical antibiotic treatment is key to preventing infection following open tibial fractures. Succeeding co-administration, we dynamically assessed the time for which vancomycin and meropenem concentrations were above relevant epidemiological cut-off (ECOFF) minimal inhibitory concentrations (T > MIC) in tibial compartments for the bacteria most frequently encountered in open fractures. Low and high MIC targets were applied: 1 and 4 µg/ml for vancomycin, and 0.125 and 2 µg/ml for meropenem. Eight pigs received a single dose of 1,000 mg vancomycin and 1,000 mg meropenem simultaneously over 100 minutes and 10 minutes, respectively. Microdialysis catheters were placed for sampling over eight hours in tibial cancellous bone, cortical bone, and adjacent subcutaneous adipose tissue. Venous blood samples were collected as references.Aims
Methods
This study evaluated target tissue concentrations of double dose cefuroxime administered intravenously as either one 15 min infusion of 3,000 mg (Group 1) or two single 15 min infusions of 1,500 mg administered 4 h apart (Group 2). Sixteen pigs were randomised into two groups of eight. Cortical and cancellous bone, synovial fluid of the knee joint and subcutaneous adipose tissue concentrations were measured based on sampling via microdialysis. Plasma samples were collected as a reference. Comparison of the groups was based on time with concentrations above relevant minimal inhibitory concentrations (Aim
Method
Systemically administered vancomycin may provide insufficient target-site concentrations. Intraosseous vancomycin administration has the potential to overcome this concern by providing high target-site concentrations. To evaluate the local bone and tissue concentrations following tibial intraosseous vancomycin administration in a porcine model.Background
Aim
Tourniquet is widely used in extremity surgery. In order to prevent surgical site infection, correct timing of antimicrobial prophylaxis and tourniquet inflation is important. We aimed to evaluate the time for which the free drug concentration of cefuroxime is maintained above the minimal inhibitory concentration (T>MIC) in subcutaneous tissue and calcaneal cancellous bone during three clinically relevant tourniquet application scenarios. Twenty-four female pigs were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in calcaneal cancellous bone and subcutaneous tissue, and a tourniquet cuff was applied on a randomly picked leg of each pig. Subsequently, the pigs were randomized into three groups to receive 1.5 g of cefuroxime by intravenous injection 15 min prior to tourniquet inflation (Group A), 45 min prior to tourniquet inflation (Group B), and at the tourniquet release (Group C). The tourniquet duration was 90 min in all groups. Dialysates and venous blood samples were collected eight-hours postcefuroxime administration.Aim
Method
Pyogenic spondylodiscitis remains a therapeutic challenge, as demonstrated by divergent treatment guidelines. The combination of moxifloxacin and rifampicin may be an attractive treatment option for cases caused by staphylococci; however, previous studies have reported a reduction in plasma concentrations of moxifloxacin when co-administered with rifampicin. The magnitude of this reduction in spinal tissues is not known. We aimed to investigate the interaction of rifampicin on moxifloxacin tissue concentrations in vertebral cancellous bone, intervertebral disc and subcutaneous adipose tissue in steady-state conditions using microdialysis in a porcine model. Twenty female pigs were randomized into two groups of ten pigs: Group A received moxifloxacin 400 mg orally once daily for three days preoperatively. Group B received moxifloxacin 400 mg orally for three days preoperatively combined with rifampicin 450 mg twice daily for seven days preoperatively. Measurements were obtained from plasma, vertebral cancellous bone, intervertebral disc and subcutaneous adipose tissue for 24 h. Microdialysis was applied for sampling in solid tissues.Aim
Method
Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications.Aims
Methods