Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 53 - 53
1 Apr 2017
Goubran A McHale S Steinlechner C
Full Access

Background

Aseptic loosening of cemented femoral stems results from migration of wear particles along the bone-cement interface, producing a foreign body reaction. After cement insertion, blood back pressure can disrupt the bone-cement interface, enabling this spread of wear particles. Our study investigates whether altering timing and speed of stem insertion can reduce this risk.

Methods

We inserted mock “C-Stem” femoral components (De Puy-Synthes), using Smartset HV cement (De Puy-Synthes) into artificial femora, fitted with proximal and distal pressure transducers. Cement insertion began two, three or four minutes after mixing. Cement pressures were then allowed to settle for one minute and the stems were then inserted over durations of 25, 60 or 90 seconds.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 265 - 265
1 Mar 2004
Ridgeway S Steinlechner C Tai C Graevett-Ball C Carey-Smith R Harrison D
Full Access

Aims: To study the outcome of lumbar spinal fusions in patients with chronic lower back pain due to degenerative spinal disorders. Methods: 85 patients with DSD’s, a mean age of 46.4 years, back pain for at least 2 years (mean=7.7years) and failed conservative treatment for at least 1 year were admitted to the study. Questionnaires recorded socio-demographic characteristics; changes in pain, clinical findings, disability (Oswestry (ODI)), employment, radiographic fusion, patient satisfaction and complications. All patients had 3, 6, 12 and 24-month follow-ups. Results: There were 37 males (44.9years) and 48 females (47.6 years) with a mean BMI of 24.8; 49% were smokers. Pain improved significantly at 3months (p< 0.001); no deterioration at 2 years with 38.4% having no back pain. Motor (p< 0.01), sensory (p< 0.05) and Oswestry Disability (0.001) improved significantly at 3 months and continued throughout. Unemployment improved significantly 30.4% to 16.5% at 2 years (p< 0.04). Radiographic fusion occurred in 91.8%, instrument failure in 11.8% and 9.4% required re-operation. Patient satisfaction revealed a significant increase in excellent (p< 0.02) and poor (p< 0.03) results. Instrument failure correlated strongly with ODI (r=0.94, p< 0.04). No other significant correlations. Conclusions:With the correct patient selection, lumbar fusions for DSD’s lead to a significantly improved outcome at 2 years, with an acceptable complication rate. There is no correlation between radiographic fusion and outcome, but instrument failure leads to significantly worse outcome