Advertisement for orthosearch.org.uk
Results 1 - 20 of 60
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 30 - 30
7 Aug 2024
Preece S Smith J Brookes N Ghio D
Full Access

Purpose

Cognitive Muscular Therapy (CMT) is a new treatment for low back pain which integrates psychological techniques for pain management alongside training to improve postural control. Rather than focus on postural alignment or strength, CMT aims to improve the regulation of postural tone (low-level activity which supports the body against gravity). This is achieved by teaching patients an awareness of compensatory paraspinal activation, which can be triggered by overactivity of the abdominal muscles.

The aim of this study was to understand whether CMT could reduce symptoms associated with low back pain and improve paraspinal muscle activation.

Methods and results

Fifteen patients with chronic low back pain received seven weekly sessions of CMT from a physiotherapist. Clinical data was captured at baseline and two weeks after the intervention using the Roland-Morris questionnaire and the pain catastrophising scale. Activation of the erector spinae muscle during walking was also measured at baseline and after the final intervention session. Change data were analysed using paired t-tests.

There was a 75% reduction (p<0.001) in the Roland-Morris score from a mean (SD) of 9.3(2.9) to 2.3(2.6), along with a 78% reduction in pain catastrophising (p<0.002) from 16.6(13) to 3.7(4.8). Activation of the contralateral erector spinae muscles reduced by 30% (p<0.01) during the contralateral swing phase of walking.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 5 - 5
1 Jul 2022
Smith J Stephens T Paulson K Schneider P Martin CR
Full Access

Abstract

Introduction

All-tissue quadriceps tendon (QT) is becoming an increasingly popular alternative to hamstrings tendon (HT) and bone-tendon-bone (BTB) autograft for anterior cruciate ligament (ACL) reconstruction. The relatively short graft length however dictates that one, or both, ends rely on suture fixation. The strength of this construct is therefore extremely important. This study evaluates whether the use of a novel fixation technique can improve the tensile properties of the construct compared to a Krackow suture, and a looped tendon (suture free) gold standard.

Methods

Eighteen porcine flexor tendons were tested, across three groups; suture-tape Krackow, looped tendon, and the novel ‘strain suture’. Biomechanical testing simulated the different stages of ACL graft preparation and loading (60N preload for 10 minutes, 10 cycles from 10N to 75N, and 1000 cycles from 100N to 400N). Elongation and load to failure were recorded, and stiffness calculated for each construct.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 46 - 46
1 Mar 2021
Valverde J Kabariti R Smith J Kelly M Murray J
Full Access

Pre-operative anaemia can present in up to 30% of elective arthroplasty patients. The presence of anaemia increases the risk of requiring blood transfusion post-operatively as well as acts as an independent risk factor for poor outcome such as prosthetic joint infection. Recent international consensus on this topic has recommended a specific care pathway for screening patients with pre-operative anaemia using a simple bedside Heaemacue finger-prick test to detect in a simple and cost-effective manner, and then allow treatment of preoperative anaemia. This pathway was therefore incorporated in our trust.

This was a retrospective study done at a single tertiary-referral arthroplasty centre. Our data collection included the Heamacue test results and formal haemoglobin levels if they were performed as well as compliance and costs of each of the tests for patients listed for an elective shoulder, hip and knee arthroplasty between September and December 2018. Medical records and demographics were also collected for these patients for subgroup analysis. Our exclusion criteria comprised patients listed for revision arthroplasty surgery.

87 patients were included in this study. Our compliance rate was 15%. The mean difference between a Haemacue test and a formal FBC result was only 17.6g/L suggesting that it has a reasonably high accuracy. With regards to costs, we found that a Haemacue test costs £2, compared to £7.50 for a full blood count and Haematinics combined. This gave an overall cost saving of £5.50 per patient. Extrapolation of this date locally for 2017 at our hospital, where 1575 primary joint arthroplasties were done, a cost saving of £8,662.5 could have been achieved. Within the UK using data extrapolated from the National Joint Registry a total of £1,102,205.5 (1,221,894 Euros) could have been saved.

The use of a single, Haemacue test to screen for pre-operative anaemia in elective arthroplasty patients is more cost effective compared to a formal full count and haematinics tests. However, we found that compliance with the care pathway is variable due to system limitations. This may be addressed through implementing changes to our electronic system in which patients are booked for surgery. We also noted a significant cost reduction if this pathway were to be used Nation-wide. Thus, we encourage other centres to consider the use of the Haemacue test pre-operatively in elective arthroplasty instead of formal full blood counts at the time of decision to treat with arthroplasty; this allows sufficient time for correction of pre-operative anaemia thus improving patient outcomes from arthroplasty.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 31 - 31
1 Mar 2021
Sun M Buckler N AlNouri M Vaughan M Hilaire TS Sponseller P Smith J Thompson G Howard J El-Hawary R
Full Access

Scoliosis is estimated to occur between 21–64% of patients with cerebral palsy (CP), where a subset of patients develops early onset scoliosis (EOS) before the age of ten. Traditional growth friendly (TGF) surgeries in the context of traditional growing rods have been shown to be effective in treating scoliosis in this population, however significant complication rates are reported. Currently, no studies have been done to examine the effect of novel growth friendly surgeries such as magnetically controlled growing rods (MCGR) on EOS in CP patients. The objective of this study is to compare MCGR with TGF surgeries in this patient population, specifically by evaluating radiographic measurements and risk of unplanned reoperations (UPRORs).

Patients with EOS secondary to CP were prospectively identified from an international database, with data retrospectively analyzed. Scoliosis (primary curve), maximum kyphosis, T1-S1 and T1-T12 height were measured pre-operation, immediate post-operation, and at two-years follow-up. The risk and etiology of UPRORs were compared between MCGR and TGF. P < 0.05 was considered statistically significant for all analyses.

Of the 120 patients that met inclusion criteria, 86 received TGF (age 7.5 ± 1.8 years; follow-up 7.0 ± 2.9 years) and 34 received MCGR (age 7.1 ± 2.2 years, follow-up 2.8 ± 0.5 years). Compared to TGF, MCGR resulted in significant improvements in maintenance of scoliosis correction (p=0.04). At final follow-up, UPRORs were 24% for MCGR (8/34 patients) and 43% (37/86 patients) for TGF (p=0.05). To minimize the influence of follow-up period, UPRORs within the first two years post-operation were evaluated: MCGR (21%, 7/34 patients) vs. TGF (14%, 12/86 patients; p=0.37). Within the first two years, etiology of UPROR as a percentage of all patients per group were deep infection (5% TGF, 6% MCGR), implant failure/migration (5% TGF, 9% MCGR), dehiscence (2% TGF, 3% MCGR), and superficial infection (1% TGF, 3% MCGR). The most common etiology of UPROR for TGF was deep infection and implant failure/migration and for MCGR was implant failure/migration.

For patients with CP, at final follow-up, MCGR had superior maintenance of scoliosis correction; however, there was no difference in risk of UPROR within the first two years post-operatively (21% MCGR, 14% TGF).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 25 - 25
1 Mar 2021
Sidhu P Smith J Chhina H Abad J Lim B Pike I Cooper A
Full Access

Supracondylar fractures of the humerus (SCH) are the most common fractures sustained following a fall on an outstretched hand in healthy children, and one of the leading causes of hospital admission and surgical intervention. With increasing severity of injury, treatment options become more invasive and the potential for long lasting complications increases. The aim of this study is to examine the causes and circumstances surrounding SCH in public play spaces particularly to determine whether or not the playground equipment implicated in injurious falls is compliant with Canadian Standards Association (CSA) standards.

Children aged 6–12 years who sustained SCH while playing at a public play space between 2017 and 2019 were recruited from the paediatric orthopaedic clinic. Public playgrounds within a 50 km radius of the clinic were visited by research assistants. Using GPS coordinates from photographs taken by the children at the site of injury or play structures identified by the children using Google Maps, play structure type, dimensions, height of fall, and the type and depth of the surface material were collected from each site and compared to the relevant CSA standard.

Of the 89 SCH injuries reported during the recruitment period, 49 (55%) occurred on public play structures. Thirty-nine injury sites, representing 42 SCH cases, were accessible to conduct site visits and were included in the analysis. Thirteen children (31%) sustained Type One, 19 (45%) were Type Two, and 10 (24%) were Type Three SCHs. The mean child age at injury was 7.13 years. Of the 42 SCH cases, 37 sites had woodchips surfacing (88%); three had rubber (7%), one had cement (2%), and one had sand (2%). Of the 36 sites where woodchip depth measurements could be obtained, only seven (19%) met the minimum CSA depth. Out of the 42 SCH cases, 29 injuries (69%) involved upper body equipment (i.e. monkey bars or similar) and track rides. Fourteen of these 29 injuries (48%) occurred on structures that did not meet CSA standards for fall height. All rotating play structures had less than half of the required clearance between the components.

Eighty-six percent of SCH cases occurred in playgrounds where at least one of the required CSA standards was not met. Woodchip surfacing was of particular concern because 81% of woodchip surface depths failed to meet CSA standards. Of the 14 injuries where fall height did not meet CSA standards, 11 (79%) also did not meet minimum CSA surface depth. Field investigation into the characteristics of playgrounds in which children sustain SCH can guide preventative policy and practice measures. Municipalities and school boards should be alerted to the need for regular maintenance of woodchip playground surfacing, in order to remain compliant with the minimum surface depth and prevent serious injuries. Additionally, compliance with minimum surface depths can also decrease fall heights to meet CSA standards. By minimizing the prevalence of SCH injuries occurring on play structures and the need for emergency department visits, the burden to healthcare systems and families of injured children can potentially be reduced.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 46 - 46
1 Jul 2020
Cooper A McCutcheon V Smith J Pike I Chhina H Sidhu P
Full Access

Supracondylar fractures of the humerus (SCH) are the most common fractures sustained following a fall among children. The majority of these fractures are mild, but the most severe injury types can result in a disruption to the nerves and blood supply resulting in limb threatening injuries and potential life-long disability. Better understanding of mechanisms of injury and child-related factors that influence injury, especially for severe cases, is crucial to identifying best practices and informing policy. We aim to stratify fractures and examine the associated mechanisms and circumstances of injury to identify best practices and inform supportive policy. In doing so, we plan to investigate why some children sustain more severe fractures than others by exploring mechanisms and locations of injury, and risk-taking behaviours.

A prospective, mixed-methods pilot study employing a child-led research design. Our approach links narratives from qualitative photo elicitation interviews (PEI) to mapped images of the locations of injury using geotagged photographs children have taken themselves, complications and injury outcomes, and an assessment of overall risk-taking tendencies.

Participants aged six-12, with the help of their photographs, were able to lay out the events leading up to, including, and following their injury. Much of this information was either not included in their medical charts or was markedly different. Themes included not being able to prevent the injury and being adventurous, as well as becoming more cautious afterwards. These can have applications to the necessity of exploration as well as possibilities to prevent injury or not. Thus, the in-depth, first-person retelling of injury mechanism illustrated the need for mechanistic data and statistics beyond injury location alone. Risk-taking behaviours, as scored by the Sensation Seeking Scale for Children, correlated to injury severity, which is known to be associated with poorer outcomes and long-lasting complications.

PEI of children sustaining SCH fractures in Vancouver reveals mechanisms of injury beyond those previously reported in literature and suggest the feasibility of a large-scale study. PEI in this age group allows for clarifications and a clearer picture of injury mechanism as well as context of injury. These aspects significantly affect our ability to determine the relationship between injury mechanism and injury severity. Mixed-methods analysis of child-directed data as well as quantitative injury demographics reveals unique translational knowledge which can be shared with clinicians, patients/care-givers, community-based health teams, and local policy makers to make timely and impactful improvements in injury prevention, clinical practice, and play structure safety.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 21 - 21
1 Apr 2018
Banks S Smith J Leadbitter I Davis N Menke J Harvey A
Full Access

The design of every post-surgical knee arthroplasty study begins with the question “How soon after surgery should we assess the patients?”. The consensus, based primarily upon clinical rating systems, is that patients' scores reach a plateau roughly one year after surgery, and that observations performed at that time should be indicative of the long-term behavior of the joint. This is satisfactory for long-term studies of clinical performance. However, when new devices are introduced there is a need to determine as quickly as possible if the device performs as designed. Waiting a year or more after surgery to characterize a device's performance may place additional patients at risk of receiving an inferior design, or may delay widespread availability of a superior design. The goal of this study was to assess knee arthroplasty patients at 6–12 weeks, 6 months and 1 year after surgery to determine if their tibiofemoral kinematics changed during functional activities.

A total of 13 patients (7 female) were recruited from an ongoing clinical study to participate in this IRB-approved sub-study. All subjects received fixed-bearing, cemented, posterior-cruciate-retaining total knee arthroplasty of the same design from a single surgeon. Subjects averaged 69 years, 169cm tall, and 28 BMI. Subjects were studied at 6–12 weeks, at 6 months and at 12 months post-surgery, when they showed an average clinical flexion of 106°, 113° and 115°, respectively. Subjects' knees were observed using pulsed-flat-panel-fluoroscopy during three activities: lunging to maximum flexion with their foot placed on a 20cm step, kneeling to maximum flexion on a padded bench, and step-up/down on a 20cm step without progression of the contralateral limb. Model-image registration was used to register 3D geometric models of the implants with their radiographic projections based upon measured projection parameters. 3D knee kinematics were derived from the registered models, including joint angles and the antero-posterior translation of the medial and lateral condyles relative to the tibial baseplate.

There were no statistically significant changes in knee kinematics between the 6–12 week and 6 month, and 6-month and 12-month visits during the kneel and lunge activities (Table 1). Similarly, there were no pair-wise differences in tibial rotation or condylar translation during the dynamic step activity at any flexion angle (Figure 1).

Traditional thinking suggests studies of knee mechanics should be performed at least one year after surgery to make observations that are predictive of long-term joint function. In three different functional activities, we could not demonstrate significant changes in knee kinematics between 6–12 weeks and 6 months, nor between 6 months and 12 months. If these results can be confirmed in a larger subject cohort, and for a range of TKA designs, then functional follow-up studies of novel knee arthroplasty designs might be justified as early as 6–12 weeks after surgery, making it possible to accelerate confirmation devices are performing in patients as designed.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 92 - 92
1 Apr 2017
Smith J Halliday R Aquilina A Hull P Kelly M
Full Access

Background

Hip fracture care has evolved, largely due to standardisation of practice, measurement of outcomes and the introduction of the Best Practice Tariff, leading to the sustained improvements documented by the National Hip Fracture Database (NHFD). The treatment of distal femoral fractures in this population has not had the same emphasis. This study defines the epidemiology, current practice and outcomes of distal femoral fractures in four English centres.

Methods

105 patients aged 50 years or greater with a distal femoral fracture, presenting to four UK major trauma centres between October 2010 and September 2011 were identified. Data was collected using an adapted NHFD data collection tool via retrospective case note and radiograph review. Local ethics approval was obtained.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 28 - 28
1 Feb 2017
Banks S Harvey A Leadbitter I Smith J
Full Access

Total knee arthroplasty (TKA) is an exceptionally successful and robust treatment for disabling knee disease, but many efforts continue to improve patient postoperative satisfaction and performance. One approach to improving performance is to restore TKA motions closer to those in healthy knees. Based upon an idealized model of knee motions, it is possible to design tibiofemoral articulating surfaces to promote natural kinematics and force transfer (Fiedler et al., Acta Bioeng Biomech, 2011). Such an asymmetric design is expected to promote rollback in stance phase that continues through deeply flexed activities. The purpose of this study is twofold: (1) To determine if a TKA designed on a theoretical basis achieves the proposed motions in vivo, and (2) To track postoperative kinematic patterns with examinations at 6–12 weeks, 6 months and one year postoperatively. This paper reports results of the initial cohort that has completed 6–12 week and 6-month examinations.

Eight patients, including 3 females, with unilateral TKA for varus osteoarthritis provided written informed consent prior to beginning the study. Patients averaged 66±9 years, 168±14cm, and 28±3 BMI. Patients performed three weightbearing activities observed using pulsed x-ray flat-panel imaging at 30Hz: stepping up from flexion to extension on a 20cm step, lunging to maximum flexion with the foot placed on a 20 cm step, and kneeling to maximum flexion with the shin placed on a padded support. Three-dimensional knee kinematics were quantified using model-image registration to determine flexion, tibial internal rotation, anteroposterior movement of the femoral condyles (relative to the tibial AP center) and average center of rotation (CoR) in the transverse plane.

During the maximum-flexion lunge and kneeling activities subjects exhibited average knee flexion of 104°–110° and tibial internal rotation of 2°–6° (Table 1). At 6–12 weeks, the medial/lateral condyles were at −3mm/−8mm and −1mm/−6mm during maximum flexion lunge and kneeling, respectively. During the stair activity from 0° to 70° flexion, there were small tibial internal rotations (1°/5°) and anterior medial (2mm/5mm) and lateral (3mm/3mm) condylar translations at both time points (Figure 1). The average CoRs for the stair activity were medial +18% and +5% for the 6–12 week and 6-month exams, respectively.

It has long been assumed knee kinematics change during a patient's first one or two postoperative years. In our early post-op cohort, changes in weight-bearing kinematics over the first 6 postoperative months are small. In maximal flexion activities, patients exhibited flexion similar to similar cohorts studied at least one year post-op (Clin Orthop, 410:131–138, 2003). Similarly, kinematics during the weight-bearing step activity were similar in pattern and magnitude to those previously reported for posterior cruciate-retaining (CR) TKA at least one year post-op (Clin Orthop, 426:187–193, 2004). The average CoRs were medial for the stair activity, which is normal for healthy knees but uncommon for CR TKA. Early post-op results with an asymmetric CR TKA implant intended to promote physiologic motion show flexion and stair kinematics similar to many successful CR designs at longer follow-up. The medial CoR indicates closer-to-physiologic motion than commonly is observed in CR TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 98 - 98
1 Dec 2016
Kadhim M El-Hawary R Vitale M Smith J Samdani A Flynn J
Full Access

To evaluate the efficacy of VEPTR in preventing further progression of scoliosis without impeding spinal growth in the treatment of children with progressive early onset scoliosis (EOS) without rib abnormalities.

Prospective, multi-center, observational cohort study on patients with EOS treated with VEPTR with 2-year follow up. Data were analysed based on measurements done pre-implant, immediate post-op and at 2-yr f/u.

Sixty-three patients met inclusion: 35 males and 28 females. Mean age at time of implantation was 6.1±2.4 yrs. Etiologies included congenital (n=6), neuromuscular (n=36), syndromic (n=4), and idiopathic (n=17). Mean follow up was 2.2±0.4 yrs. Scoliosis (72o±18o) decreased after implant surgery (47o±17o) followed by slight increase at 2-yr f/u (57o±18o), p<0.0001.

At 2-yr f/u, VEPTR was effective in treating EOS without rib abnormalities with 86% of patients having an improvement in scoliosis and 94% of patients having an increased spinal height as compared to pre-operatively. VEPTR provided greater than 100% of expected age-matched spine growth and the instrumented spinal segment continued to grow during distraction phase. This large prospective, multicentre study demonstrated the ability of VEPTER to effectively treat EOS without rib abnormalities. Goals of preventing further scoliosis progression and of maintaining normal spine growth were achieved.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_15 | Pages 12 - 12
1 Sep 2016
Robinson P Piggott R Bennett S Smith J Pople I Edwards R Clarke A Atherton W
Full Access

We present the 2 year results for the first 54 patients after Selective Dorsal Rhizotomy (SDR) delivered in Bristol, concentrating on change in Reimers' migration index.

Eligible patients are selected at the SDR multidisciplinary meeting. Physiotherapy assessment is performed pre-operatively and at 6, 12 and 24 months post-surgery. Data collected includes GMFCS, Gross Motor Function Measure (GMFM) 88 and Modified Ashworth score for spasticity for major lower limb muscle groups, amongst other data. Pelvic radiographs are taken pre-operatively and at 2 years post-operatively. Reimers' migration index was measured using the hospital picture archiving and communication system (PACS).

The mean age was 7.2 (3.9–17.5) at the time of surgery. Pre- and post-operative pelvic radiographs were available for 30 patients (60 hips). 57% (n=34) hips showed an increase in migration percentage (mean 5.4%, range 0.1–17.5%) and 43% (n=26) hips showed a decrease (mean 4.0%, range 0–15.5%). Overall no significant difference was found in Reimers' migration index at 2 year follow up (mean increase 1.3% (95% CI −0.3–3.0), p=0.12).

There was an improvement in GMFCS category (by 1 grade) for 9 patients and a worsening for 1 patient at 2 year follow up. The Modified Ashworth score for spasticity improved in all patients. There was a mean improvement of 1.7 in the hip adductors and 2.4 in the ankle plantar flexors.

There was a statistically significant improvement in the GMFM 88 D and E domains of 14.7 (95% CI 11.3–18.1), p<0.0001 and 11.4 (95% CI 7.4–15.7), p<0.0001 respectively.

We found no evidence that SDR leads to worsening hip subluxation at 2 year follow up. All patients had improvement in lower limb spasticity. Overall there was a statistically significant improvement in function, as shown by GMFM 88 domains for standing, walking, running and jumping.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 33 - 33
1 Feb 2016
Gregori A Smith J Picard F Lonner J Jaramaz B
Full Access

Utilisation of unicondylar knee arthroplasty (UKA) has been limited due in part to high revision rates. Only 8% of knee arthroplasty surgeries completed in England and Wales are UKAs. It is reported that the revision rate at 9 years for Total Knee Arthroplasty (TKA) was 3% compared to 12% for UKAs. In the last decade semi active robots have been developed to be used for UKA procedures. These systems allow the surgeon to plan the size and orientation of the tibial and femoral component to match the patient's specific anatomy and to optimise the balancing the soft tissue of the joint. The robotic assistive devices allow the surgeon to execute their plan accurately removing only ‘planned’ bone from the predefined area. This study investigates the accuracy of an imageless navigation system with robotic control for UKA, reporting the errors between the ‘planned’ limb and component alignment with the post-operative limb and component alignment using weight bearing long leg radiographs. We prospectively collected radiographic data on 92 patients who received medial UKA using an imageless robotic assisted device across 4 centres (4 surgeons). This system is CT free, so relies on accurate registration of intra-operative knee kinematic and anatomic landmarks to determine the mechanical and rotational axis systems of the lower limb. The surface of the condylar is based on a virtual model of the knee created intra-operatively by ‘painting’ the surface with the tip of a tracked, calibrated probe. The burring mechanism is robotically controlled to prepare the bone surface and remove the predefined volume of bone. The study shows the 89% of the patients' post-operative alignment recorded by the system was within 30 of the planned coronal mechanical axis alignment. The RMS error was 1.980. The RMS errors between the robotic system's implant plan and the post-operative radiographic implant position was; femoral coronal alignment (FCA) 2.6o, tibial coronal alignment (TCA) 2.9o and tibial slope (TS) 2.9o. In conclusion, the imageless robotic surgical system for UKA accurately prepared the bone surface of the tibia and femur which resulted in low errors when comparing planned and achieved component placement. This resulted in a high level of accuracy in the planned coronal mechanical axis alignment compared to that measured on post-operative radiographs.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 9 - 9
1 May 2015
Smith J Lankester B
Full Access

Medial patellofemoral ligament (MPFL) reconstruction is an effective procedure to address patellofemoral instability, however there remains no clear consensus on the optimum technique. Variations in patella tunnel and the use of patella fixation devices are reported in the literature, as are the associated complications of patella fracture and hardware irritation. We present the early results using a two tunnel, Endobutton free technique.

24 MPFL reconstructions (14 female, 10 male) were performed by a single surgeon, using two 3.5mm medial patellar tunnels exiting anteriorly and a looped, extra-synovial hamstring autograft. Femoral fixation was achieved using an non-absorbable interference screw. Mean age was 25.5 years, with a mean follow-up of 21.7 months. Mean Kujala scores were 60.8 preoperatively and 87.9 postoperatively (p<0.0001). No patient experienced further dislocation or patella fracture post-operatively. One patient required interference screw removal.

The surgical technique presented has outcomes comparable with the literature. It requires a shorter tendon graft, and removes the need for a patellar fixation device, reducing potential irritation and cost.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 18 - 18
1 May 2015
Berstock J Torrie P Smith J Webb J Baker R
Full Access

Cement-in-cement femoral component revision is a useful and commonly practised technique. Onerous and hazardous re-shaping of the original cement mantle is required if the new stem does not seat easily. Furthermore, without removing the entirety of the original cement mantle, the freedom to alter anteversion or leg length is difficult to predict preoperatively. We present data from in vitro experiments testing the compatibility of the top cemented stems according to UK registry figures (NJR 2013). This data augments preoperative planning by indicating which revision stems require minimal or no cement reshaping when being inserted into another stem's mantle. We also present the maximum shortening and anteversion that can be achieved without reshaping the original cement mantle.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 22 - 22
1 Nov 2014
Willmott H Smith J Taylor H
Full Access

Introduction:

The cavovarus foot is a complex deformity caused by muscle imbalance, soft-tissue contracture and secondary bony abnormality. It is a combination of hindfoot, midfoot and forefoot deformity and the decision making process for surgical management can be difficult. The process of deciding which combination of procedures is required is often poorly understood. We present an algorithm to assist with this decision making.

Methods:

We have analysed a single surgeon's experience of cavovarus foot correction, from a consecutive series of 50 patients over 5 years, to develop an algorithm to guide operative decision making. Cases included cavovarus deformity secondary to cerebral palsy, Friedreich's ataxia, Charcot Marie Tooth disease, post-traumatic contracture, post-cerebrovascular accident, iatrogenic post-surgery and physiological cavus. We have taken a systematic approach to each component of the deformity in order to generate the algorithm.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 13 - 13
1 Oct 2014
Wallace D Gregori A Picard F Bellemans J Lonner J Marquez R Smith J Simone A Jaramaz B
Full Access

Unicondylar knee arthroplasty (UKA) is growing in popularity with an increase in utilisation. As a less invasive, bone preserving procedure suitable for knee osteoarthritic patients with intact cruciate ligaments and disease confined to one compartment of the knee joint. The long term survival of a UKA is dependent on many factors, including the accuracy of prosthesis implantation and soft tissue balance. Robotic assisted procedures are generally technically demanding, can increase the operation time and are associated with a learning curve. The learning curve for new technology is likely to be influenced by previous experience with similar technologies, the frequency of use and general experience performing the particular procedure. The purpose of this study was to determine the time to achievement of a steady state with regards to surgical time amongst surgeons using a novel hand held robotic device.

This study examined consecutive UKA cases which used a robotic assistive device from five surgeons. The surgeons had each performed at least 15 surgeries each. Two of the surgeons had previous experience with another robotic assistive device for UKA. All of the surgeons had experience with conventional UKA. All of the surgeons have used navigation for other knee procedures within their hospital. The system uses image free navigation with infrared optical tracking with real time feedback. The handheld robotic assistive system for UKA is designed to enable precision of robotics in the hands of the surgeon. The number of surgeries required to reach ‘steady state’ surgical time was calculated as the point in which two consecutive cases were completed within the 95% confidence interval of the surgeon's ‘steady state’ time.

The average surgical time (tracker placement to implant trial acceptance phase) from all surgeons across their first 15 cases was 56.8 minutes (surgical time range: 27–102 minutes). The average improvement was 46 minutes from slowest to quickest surgical times. The ‘cutting’ phase was reported as decreasing on average by 31 minutes. This clearly indicates the presence of a learning curve. The surgeons recorded a significant decrease in their surgical time where the most improvement was in the process of bone cutting (as opposed to landmark registration, condyle mapping and other preliminary or planning steps). There was a trend towards decreasing surgical time as case numbers increase for the group of five surgeons. On average it took 8 procedures (range 5–11) to reach a steady state surgical time. The average steady state surgical time was 50 minutes (range 37–55 minutes).

In conclusion, the average operative time was comparable with clinical cases reported using other robotic assistive devices for UKA. All five surgeons using the novel handheld robotic-assisted orthopaedic system for UKA reported significant improvement in bone preparation and overall operative times within the first 15 cases performed, reaching a steady state in surgical times after a mean of 8 cases. Therefore, this novel handheld device has a similar learning curve to other devices on the market.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 12 - 12
1 Oct 2014
Smith J Picard F Lonner J Hamlin B Rowe P Riches P Deakin A
Full Access

Knee osteoarthritis results in pain and functional limitations. In cases where the arthritis is limited to one compartment of the knee joint then a unicondylar knee arthroplasty (UKA) is successful, bone preserving option. UKA have been shown to result in superior clinical and functional outcomes compared to TKA patients. However, utilisation of this procedure has been limited due primarily to the high revision rates reported in joint registers. Robotic assisted devices have recently been introduced to the market for use in UKA. They have limited follow up periods but have reported good implant accuracy when compared to the pre-operative planned implant placement.

UKA was completed on 25 cadaver specimens (hip to toe) using an image-free approach with infrared optical navigation system with a hand held robotically assisted cutting tool. Therefore, no CT scan or MRI was required. The surface of the condylar was mapped intra operatively using a probe to record the 3 dimensional surface of the area of the knee joint to be resurfaced. Based on this data the size and orientation of the implant was planned. The user was able to rotate and translate the implant in all three planes. The system also displays the predicted gap balance graph through flexion as well as the predicted contact points on the femoral and tibial component through flexion. The required bone was removed using a bur. The depth of the cut was controlled by the robotically controlled freehand sculpting tool.

Four users (3 consultant orthopaedic surgeon and a post-doctoral research associate) who had been trained on the system prior to the cadaveric study carried out the procedures. The aim of this study was to quantify the differences between the ‘planned’ and ‘achieved’ cuts. A 3D image of the ‘actual’ implant position was overlaid on the ‘planned’ implant image. The errors between the ‘actual’ and the ‘planned’ implant placement were calculated in three planes and the three rotations. The maximum femoral RMS angular error was 2.34°. The maximum femoral RMS translational error across all directions was up to 1.61mm. The maximum tibial RMS angular error was 2.60°. The maximum tibial RMS translational error across all directions was up to 1.67mm.

In conclusion, the results of this cadaver study reported low RMS errors in implant position placement compared to the plan. The results were comparable with those published from clinical studies investigating other robotic orthopaedic devices. Therefore, the freehand sculpting tool was shown to be a reliable tool for cutting bone in UKA and the system allows the surgeon to plan the placement of the implant intra operatively and then execute the plan successfully.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 25 - 25
1 Oct 2014
Picard F Gregori A Bellemans J Lonner J Smith J Gonzales D Simone A Jaramaz B
Full Access

For patients suffering from osteoarthritis confined to one compartment of the knee joint, a successful unicondylar knee arthroplasty (UKA) has demonstrated an ability to provide pain relief and restore function while preserving bone and cruciate ligaments that a total knee arthroplasty (TKA) would sacrifice. Long-term survival of UKA has traditionally been inconsistent, leading to decreased utilisation in favour of alternative surgical treatment. Robot-assisted UKA has demonstrated an ability to provide more consistent implantation of UKA prosthesis, with the potential to increase long-term survivorship.

This study reports on 65 patients undergoing UKA using an image-free, handheld robotic assistive navigation system. The condylar surface was mapped by the surgeon intra-operatively using a probe to capture a 3-dimensional representation of the area of the knee joint to be replaced. The intra operative planning phase allows the surgeon to determine the size and orientation of the femoral and tibial implant to suit the patients’ anatomy. The plan sets the boundaries of the bone to be removed by the robotic hand piece. The system dynamically adjusts the depth of bone being cut by the bur to achieve the desired result. The planned mechanical axis alignment was compared with the system's post-surgical alignment and to post-operative mechanical axis alignment using long leg, double stance, weight bearing radiographs.

All 65 knees had knee osteoarthritis confined to the medial compartment and UKA procedures were completed using the handheld robotic assistive navigation system. The average age and BMI of the patient group was 63 years (range 45–82 years) and 29 kg/m2 (range 21–37 kg/m2) respectively. The average pre-operative deformity was 4.5° (SD 2.9°, Range 0–12° varus). The average post-operative mechanical axis deformity was corrected to 2.1° (range 0–7° varus). The post-operative mechanical axis alignment in the coronal plane measured by the system was within 1° of intra-operative plan in 91% of the cases. 3 out of 6 of the cases where the post-operative alignment was greater than 1° resulted due to an increase in the thickness of the tibia prosthesis implanted. The average difference between the ‘planned’ mechanical axis alignment and the post-operative long leg, weight bearing mechanical axis alignment was 1.8°. The average Oxford Knee Score (old version) pre and post operation was 38 and 24 respectively, showing a clinical and functional improvement in the patient group at 6 weeks post-surgery.

The surgical system allowed the surgeons to precisely plan a UKA and then accurately execute their intra operative plan using a hand held robotically assisted tool. It is accepted that navigation and robotic systems have a system error of about 1° and 1mm. Therefore, this novel device recorded accurate post-operative alignment compared to the ‘planned’ post-operative alignment. The patients in this group have shown clinical and functional improvement in the short term follow up. The importance of precision of component alignments while balancing existing soft-tissue structures in UKA has been documented. Utilisation of robotic-assisted devices may improve the accuracy and long-term survivorship UKA procedure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 68 - 68
1 Aug 2013
Smith J Picard F Rowe P Deakin A Riches P
Full Access

Unicondylar knee arthroplasty (UKA) is a treatment for osteoarthritis when the disease only affects one compartment of the knee joint. The popularity in UKA grew in the 1980s but due to high revision rates the usage decreased. A high incidence of implant malalignment has been reported when using manual instrumentation. Recent developments include surgical robotics systems with navigation which have the potential to improve the accuracy and precision of UKA.

UKA was carried out using an imageless navigation system – the Navio Precision Freehand Sculpting system (Blue Belt Technologies, Pittsburgh, USA) with a medical Uni Knee Tornier implant (Tornier, Montbonnot Saint Martin, France) on nine fresh frozen cadaveric lower limbs (8 males, 1 females, mean age 71.7 (SD 13.3)). Two users (consultant orthopaedic surgeon and post doctoral research associate) who had been trained on the system prior to the cadaveric study carried out 4 and 5 implants respectively. The aim of this study was to quantify the differences between the planned and achieved cuts.

A 3D image of the ‘actual’ implant position was overlaid on the planned implant image. The errors between the ‘actual’ and the planned implant placement were calculated in three planes and the three rotations. The maximum femoral implant rotational error was 3.7° with a maximum RMS angular error of 2°. The maximum femoral implant translational error was 2.6mm and the RMS translational error across all directions was up to 1.1mm. The maximum tibial implant rotational error was 4.1° with a maximum RMS angular error was 2.6°. The maximum translational error was 2.7mm and the RMS translational error across all directions was up to 2.0mm.

The results were comparable to those reported by other robotic assistive devices on the market for UKA. This technology still needs clinical assessment to confirm these promising results.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 69 - 69
1 Aug 2013
Smith J Blyth M Jones B MacLean A Rowe P
Full Access

Total knee arthroplasty (TKA) has been established as a successful procedure for relieving pain and improving function in patients suffering from severe knee osteoarthritis for several decades now. It involves removing bone from both the medial and lateral compartments of the knee and sacrificing one or both of the cruciate ligaments. This in turn is likely to have an impact on the patients' functional outcome. In subjects where only one compartment of the knee joint is affected with osteoarthritis then unicondylar knee arthroplasty (UKA) has been proposed as an alternative procedure to TKA. This operation preserves the cruciate ligaments and removes bone only from the affected side of the joint. As a result there is the possibility of an improved functional outcome post surgery. UKA has been associated with faster recovery, good functional outcome in terms of range of motion and it is bone sparing compared to TKA. However, the biggest obstacle to UKA success is the high failure rates.

The aim of this study was to compare the functional outcome of computer navigated TKA (n=60) and UKA (n=42) patients 12 month post operation using flexible electrogoniometry. Flexible electrogoniometry was used to investigate knee joint kinematics during gait, slopes walking, stair negotiation, and when using standard and low chairs. Maximum, minimum and excursion knee joint angles were calculated for each task.

The biomechanical assessment showed statistically significant improvements in the knee kinematics in terms of maximum (p<0.0004) and excursion (p<0.026) knee joint angles in the UKA patient group compared to the navigated TKA group for each of the functional tasks. There was no statistically significant difference between the minimum knee joint angles during these functional tasks (p>0.05).

Therefore, UKA patients were showed to have a significantly better functional outcome in terms of the maximum knee joint angle during daily tasks. A limitation of this study is that it compares two cohorts rather than two randomised groups. It is expected that UKA patients will have a better functional outcome. Our results suggest that for patients with less severe knee osteoarthritis, UKA may offer a better functional outcome than the more common surgical option of TKA. The recent advancements in computer assisted and robotic assisted knee arthroplasty has the possibility to improve the accuracy of UKA and therefore led to the increase in confidence and in usage in a procedure which has the potential to give patients a superior functional outcome.