Due to the recent rapid expansion of scooter sharing companies, there has been a dramatic increase in the number of electric scooter (e-scooter) injuries. Our purpose was to conduct a systematic review to characterize the demographic characteristics, most common injuries, and management of patients injured from electric scooters. We searched PubMed, EMBASE, Scopus, and Web of Science databases using variations of the term “electric scooter”. We excluded studies conducted prior to 2015, studies with a population of less than 50, case reports, and studies not focused on electric scooters. Data were analyzed using Aims
Methods
In anticipation of reduced workload and need for minimisation of staff contact with infectious patients during the COVID-19 lockdown in 2020, Cairns Hospital reduced the junior orthopaedic staffing and absolved team structure. We performed a retrospective audit of our department's workload during a predetermined three week period during the 2020 lockdown and in 2019.Introduction and Objective
Materials and Methods
Management of gap non-union of the tibia, the major weight bearing bone of the leg remains controversial. The different internal fixation techniques are often weighed down by relatively high complication rates that include fractures which fail to heal (non-union). Minimally invasive techniques with ring fixators and bone transport (distraction osteogenesis) have come into picture as an alternative allowing alignment and stabilization, avoiding a graduated approach. This study was focused on fractures that result in a gap non-union of > 6 cm. Ilizarov technique was employed for management of such non-unions in this case series. The Ilizarov apparatus consists of rings, rods and kirschner wires that encloses the limb as a cylinder and uses kirschner wires to create tension allowing early weight bearing and stimulating bone growth. Ilizarov technique works on the principle of distraction osteogenesis, that is, pulling apart of bone to stimulate new bone growth. Usually, 4–5 rings are used in the setup depending on fracture site and pattern for stable fixation. In this study, we demonstrate effective bone transport and formation of gap non-union more than 6 cm in 10 patients using only 3 rings construct Ilizarov apparatus. This case study was conducted at Dr. D. Y. Patil Medical Hospital, Navi Mumbai, Maharashtra, India. The study involved 10 patients with a non-union or gap > 6 cm after tibial fracture. 3 rings were used in the setup for the treatment of all the patients. Wires were passed percutaneously through the bone using a drill and the projecting ends of the wires were attached to the metal rings and tensioned to increase stability. The outcome of the study was measured using the Oxford Knee scoring system, Functional Mobility Scale, the American Foot and Ankle Score and Visual Analog Scale. Further, follow up of patients was done upto 2 years.Introduction and Objective
Materials and Methods
Hip arthroscopy is becoming more popular. A literature review demonstrated paucity of published papers reporting the outcome of hip arthroscopy in teenagers without developmental dysplasia of the hip. Our aim was to record the type of lesions found and report the outcome and level of satisfaction following hip arthroscopy in teenagers. From 2002 to 2008, 96 hip arthroscopies were undertaken in 76 patients. Pre-operative and two-week, six-week and current post-operative assessments were performed using the modified Harris hip score (HHS) and the Non Arthritic Hip Score (NAHS). In addition, a satisfaction survey was completed at their most recent review. Patients enrolled in the study were under the age of 20. Patients with a history of developmental dysplasia of the hip, Perthes disease and arthritis were excluded from the study. Patients had at least a six-month follow-up from their surgery. Our study cohort comprised 53 males and 43 females with an average age of 17 years old (range 13 to 19 years). The average duration of follow up was 19 months (range 3 to 75 months). There were 41 left and 54 right-sided hip arthroscopies. There were five re-operations. The average duration of hip traction was 19 minutes (range 6 to 47 minutes). We found pathology in all hips that underwent arthroscopy. We report a significant improvement in MHHS and NAHS at six weeks and current review (p-value <0.01). Sixty-two percent of patients had returned to sport at the previous level of competition, 32% of patients returned to sport at a lower level of competition and 5% patients did not return to sport. Overall, 84% of patients were satisfied following their hip arthroscopy and 91% would have the surgery again if they had to. There were five re-operations. Our study has revealed a range of intra articular hip pathologies amenable to surgical treatment using hip arthroscopy. We have observed a significant improvement in hip scores; with up to 94% of patients returning to sport in the short term with high satisfaction levels. Long term follow up of this group is ongoing.
We report our ten year experience of primary haematogenous non-tuberculous spinal infection. Retrospective case note review of 42 patients presented to our institution with primary spinal infection during 1995-2005 was carried out. Demographic data, timing and modes of presentation, investigations, and methods of treatment were analysed. The cost benefit of Home Intravenous Antibiotics Service (HIAS) was also investigated.Aim
Method
Publication of normal and expected outcome scores is necessary to provide a benchmark for auditing purposes following arthroplasty surgery. We have used the Oxford knee score to monitor the progress of knee replacements undertaken since 1995, the start of our review programme. 4847 Oxford assessments were analysed over an 8 year follow-up period. The mean pre-operative Oxford knee score was 39.2, all post-operative reviews showed a significant improvement. Patients with a BMI >
40, and the under 50 age group showed early deterioration in outcome scores, returning to pre-operative levels by 5 and 7 years respectively. There was no significant difference in outcome between surgeons performing <
20 knee replacements a year and those performing >
100 / year. The age of the patient at the time of surgery and the pre-operative body habitus have been identified as factors affecting long term outcome of total knee replacement surgery. Awareness of these factors may assist surgeons in advising patients of their expected outcomes following surgery.
Mobility score dropped in 34% patients whilst domestic circumstances’ score dropped only in 34%. ODI averaged 18% (range 0–53%). Mean HAD for anxiety and depression was normal for 86% and 93% of patients respectively. VAS for pain averaged 1.3 (range 0–9) and that for distress was 1.8 (range 0–9). Overall it was calculated that HIAS had saved a total of 940 in-patient days.
Mean duration of symptoms was 25 days (range 1–202). Mean time from presentation to diagnosis was 19 days (range 0–172). Staphylococcus Aureus was the most common organism. Mean duration of Intravenous antibiotics was 60 days (range 13–240) followed by oral antibiotics for mean duration of 65 days (range 0–161). CRP was more reliable in monitoring the disease over time. At mean follow up of 5.4 years (0.6–10.5) there has been no mortality directly related to the infection. With our management there has been 14% recurrence rate. All re- presenting within the first year after initial presentation (Mean 5.5 Months, range 1–11). HIAS saved a total of 940 in-patient days with a total cost saving of approximately £350,000.00.
Demographics: The mechanism of injury was a road traffic accident in 80% and the mean ISS was 24.1. There were 95 patients (10.9%) with a cervical spine fracture, 96 (10.8%) with a fracture in either / both thoracic and lumbar regions. Spine clearance: Mean intubation (7.1 days), time to spine clearance (mean 0.4 days). In 318 patients, clearance was performed with the patient conscious (284 prior to intubation, 34 after intubation of <
24hrs). 42 patients (4.6%) died before spine clearance. In 10 patients, the protocol was not followed. Inclusions: 434 patients underwent CT. 10 of the 95 cervical fractures were deemed stable and underwent DS (n = 349). Missed Cases: CT missed 2 cases of instability, one of these (an atlanto-occipital dislocation) was also missed by DS. Critical analysis revealed a Powers ratio calculation would have diagnosed this injury on CT. Sensitivity (CT 97.7% vs DS 98.8%), specificity (100% CT and DS). There were no complications from either procedure.
We report a three year Medical Devices Agency and Local Ethical Committee approved prospective study for a new tri-tapered polished cannulated cemented femoral component. Our stem was implanted in 53 primary total hip replacements. Eleven male patients (11 hips) and 39 female patients (39 hips). The mean age at surgery was 73 (range 65 to 84). The mean weight was 71.76 kg (range 49.3 kg to 94.6 kg) with a mean BMI of 28 (range 20.20 to 40.26). All patients had a pre operative diagnosis of osteoarthritis. All the hips were implanted via the anterolateral approach. Twenty-six (51%) hips were implanted by a single consultant and 24 (49%) were implanted by six different registrars. Pre-operative and sequential post-operative clinical and radiological evaluations were undertaken. The mean pre-operative Oxford hip score was 47 points.which declined 19 points at three years. Radiological analysis, using the Johnston criteria, did not reveal any untoward features. Prosthetic stem migration was measured using a technique developed in our unit and validated as accurate to 0.61 mm; as previously reported. Stem migration measured averaged 1.38 mm (n=52; sd ±1.38) 6 months post implantation. This progressed to 1.71 mm (n=50; SD=1.18) at one year; 1.61mm (n=48; sd ±1.17) at 2 years. and 1.55 mm (n=28; SD 1.13). At 3 years average stem migration for hips implanted by the registrar group and the consultant group was not sig-nificantly different (p=0.2048) and the migration curve, against time was similar for both groups. Our study has demonstrated initial component migration, comparable to that of other polished tapered cemented stem designs. The improvement in Oxford hip score parallels other reported series and no adverse radiological signs have been observed. Long-term surveillance of our cohort will provide further data to compare the new design with substantial equivalents. More sophisticated studies, such as RSA analysis would provide further data on early femoral component migration.
Radiographic results showed no evidence of loosening of HA coated cups, in contrast to non HA coated cups which migrated significantly in 80% of cases. Four patients with loose non HA coated cups underwent revision surgery.
Hip resurfacing is widely recognised as a bone conserving procedure with respect to proximal femoral resection. However, it has been argued that this is not the case for the acetabulum due to the thickness of the acetabular component and the large diameter bearing surfaces. We have investigated whether the Birmingham Hip is a bone conserving procedure with respect to the acetabular bone stock. Data was obtained from 257 consecutive Midland Medical Technology (MMT) surface replacements and 458 primary hybrid total hip replacements implanted under our care. The surface replacement group comprised 185 males (185 hips) and 72 females (72 hips) with a mean age at surgery of 55 years. The hybrid primary total hip replacement group comprised 207 males (207) and 251 females (251 hips). The mean age at surgery was 65 years old. In the surface replacement group the mean uncemented acetabular size implanted was 54.88 mm (females = 51.9 mm; males = 57.8 mm). In the hybrid primary total hip replacement group the mean uncemented acetabular size of 55.04 mm (females =52.9 mm; males = 57.2 mm). Statistical analysis was undertaken to compare the uncemented acetabular sizes in the surface replacement group with the uncemented acetabular sizes implanted in the primary hybrid total hip replacement group. We report no significant difference in the size of acetabular component used for the two groups (p = 0.4629; 95% C.I. −0.28 to 0.61). The effect of gender was analysed and the mean size of uncemented acetabular component implanted in males for the surface replacement group was not significantly different (p = 0.06) to the hybrid primary total hip replacement group. However the mean size of uncemented acetabular component in females for the surface replacement group was significantly smaller (p = 0.016) compared to the primary total hip replacement group. We conclude hip resurfacing is not bone sacrificing on the acetabular bone stock and can be bone conserving for females.
The novel horseshoe shaped cup was designed by the senior authors to minimise the resection of healthy bone in total hip arthroplasty. It replaces the cartilage and underlying sub-chondral bone of the acetabulum socket with a cup that is designed to flex in harmony with the surrounding bony structure. Fifty female patients with a displaced, subcapital, femoral neck fractures were chosen for the study. In half of the group of patients, the composite support shell was coated with HA, with the other half remaining uncoated. Clinical and radiological assessments were undertaken regularly for five years. To date 20 patients have died and 13 have withdrawn from the study due to poor medical health unrelated to the study. Charnley modified Merle d’Aubigne score at five years was as good as the preoperative score with 80% of patients having full range of movement, no pain and walking unaided. Radiographic results showed no evidence of loosening of HA coated cups, in contrast to non HA coated cups which migrated significantly in 80% of cases. Four patients with loose non HA coated cups underwent revision surgery. This trial has demonstrated success at 5 years with the HA coated Cambridge Acetabular Cup. Cups from which HA coating has been removed have migrated significantly in 80% of cases. There is an advantage of the HA fixation which will be taken into account before wider clinical usage is advocated.