header advert
Results 1 - 10 of 10
Results per page:
Bone & Joint Research
Vol. 13, Issue 7 | Pages 353 - 361
10 Jul 2024
Gardete-Hartmann S Mitterer JA Sebastian S Frank BJH Simon S Huber S Löw M Sommer I Prinz M Halabi M Hofstaetter JG

Aims

This study aimed to evaluate the BioFire Joint Infection (JI) Panel in cases of hip and knee periprosthetic joint infection (PJI) where conventional microbiology is unclear, and to assess its role as a complementary intraoperative diagnostic tool.

Methods

Five groups representing common microbiological scenarios in hip and knee revision arthroplasty were selected from our arthroplasty registry, prospectively maintained PJI databases, and biobank: 1) unexpected-negative cultures (UNCs), 2) unexpected-positive cultures (UPCs), 3) single-positive intraoperative cultures (SPCs), and 4) clearly septic and 5) aseptic cases. In total, 268 archived synovial fluid samples from 195 patients who underwent acute/chronic revision total hip or knee arthroplasty were included. Cases were classified according to the International Consensus Meeting 2018 criteria. JI panel evaluation of synovial fluid was performed, and the results were compared with cultures.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 72 - 72
24 Nov 2023
Mitterer JA Frank BJ Guger M Schoefberger L Simon S Huber S Autherith M Hofstätter J
Full Access

Background

Data regarding the diagnostic value of ultrasound (US)-determined fluid film and joint aspiration prior to revision total hip arthroplasty (THA) for suspected periprosthetic joint infections (PJIs) is limited. This study aimed to analyse (1) the value of US-determined fluid film, (2) characterisation of the pre- and intraoperative microbiological spectrum and resistance patterns and (3) the concordance between preoperative synovial fluid and intraoperative culture results.

Methods

We analysed 366 US-examinations from 340 patients prior to revision THA. Selected cases were categorized into clearly infected, non-infected and inconclusive, according to the International Consensus Meeting (ICM) 2018 Criteria. If US-determined fluid film was <1mm, no aspiration was performed based on our institutional standard protocol. Patients were grouped into no-aspiration (144/366;[39.3%]), dry-tap (21/366;[5.7%]) and a successful-tap (201/366;[54.9%]). The microbiological spectrum and antibiotic resistance patterns were determined and differences were compared between pre- and intraoperative results.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 60 - 60
24 Nov 2023
Simon S Frank BJ Hartmann SG Mitterer JA Sujeesh S Huber S Hofstaetter JG
Full Access

Aims

The aim of this study was to assess the incidence the microbiological spectrum and clinical outcome of hip and knee revision arthroplasties with unexpected-positive-intraoperative-cultures (UPIC) at a single center with minimum follow up of 2 years.

Methods

We retrospectively analyzed our prospectively maintained institutional arthroplasty registry. Between 2011 and 2020 we performed presumably aseptic rTHA (n=939) and rTKA (n= 1,058). Clinical outcome, re-revision rates and causes as well as the microbiological spectrum were evaluated.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 67 - 67
24 Nov 2023
Gardete-Hartmann S Simon S Frank BJ Sebastian S Loew M Sommer I Hofstaetter J
Full Access

Aim

Synovial calprotectin point-of-care test (POC) has shown promising clinical value in diagnosing periprosthetic joint infections (PJIs). However, limited data are available in unclear cases. Moreover, cut-off values for calprotectin lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) need to be adapted. The aim of this study was to evaluate the performance of an upgraded and more sensitive version of a synovial calprotectin LFA along with ELISA immunoassay in patients with septic, aseptic, and unclear cases.

Methods

Overall, 206 prospectively collected periprosthetic synovial fluid samples from 169 patients (106f/63m; 38 hip/131 knee) who underwent revision surgeries were retrospectively evaluated for calprotectin concentration. The following groups were analyzed: unexpected negative cultures (UNC; 32/206), unexpected positive cultures (UPC; 28/206), and unclear cases (65/206) with conflicting clinical results. In addition, we added a true aseptic (40/206), and true septic (41/206) control groups according to the international consensus meeting (ICM) 2018 PJI classification. Calprotectin concentration was determined by a rapid quantitative LFA (n=206) (Lyfstone®, Norway), and compared to calprotectin ELISA immunoassay (171/206). For the determination of a new calprotectin cut-off value, analysis of the area under the curve (AUC) followed by Youden's J statistic were performed using the calproctectin values from clear septic and aseptic cases. Sensitivity and specificity for calprotectin were calculated. All statistical analyses were performed using IBM-SPSS® version 25 (Armonk, NY, USA).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 5 - 5
1 Oct 2022
Hartmann S Mitterer JA Frank BJH Simon S Prinz M Dominkus M Hofstätter J
Full Access

Aim

Culture-based conventional methods are still the gold standard to identify microorganisms in hip and knee PJIs diagnosis. However, such approach presents some limitations due to prior antimicrobial treatment or the presence of unusual and fastidious organisms. Molecular techniques, in particular specific real-time and broad-range polymerase chain reaction (PCR), are available for diagnostic use in a suspected PJI. However, limited data is available on their sensitivity and specificity.

This study aimed to evaluate the performance of a rapid and simple Investigational Use Only (IUO) version of the BioFire® JI multiplex PCR panel when compared to traditional microbiological procedures.

Method

Fifty-eight native synovial fluid samples were recovered from 49 patients (female n=26; male =23) who underwent one or multiple septic or aseptic revision arthroplasties of the hip (n=12) and knee (n=46). The JI panel methodology was used either on specimens freshly collected (n=6) or stored at −80°C in our Musculoskeletal Biobank (n=52). The JI panel performance was evaluated by comparison with culture reference methods. Patient's medical records were retrieved from our institutional arthroplasty registry as well as our prospectively maintained PJI infection database.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 22 - 22
1 Oct 2022
Frank BJ Aichmair A Hartmann S Simon S Dominkus M Hofstätter J
Full Access

Aim

Analysis of microbiological spectrum and resistance patterns as well as the clinical outcome of patients who underwent a Debridement, antibiotics and implant retention (DAIR) procedure in the early phase following failed two-stage exchange arthroplasty of the knee and hip.

Method

Of 312 patients treated with two-stage exchange arthroplasty between January 2011 and December 2019, 16 (5.1%) patients (9 knee, 7 hip) underwent a DAIR procedure within 6 months following second stage. We retrospectively analyzed the microbiological results as well as changes in the microbiological spectrum and antibiotic resistance patterns between stages of two-stage exchange arthroplasties and DAIR procedures. Patient's re-revision rates after a minimum follow-up of 12 months following DAIR procedure were evaluated. Moreover, differences between knee and hip and between infected primary total joint replacement (TJRs) and infected revision TJRs as well as patient's host factors and microbiological results regarding the outcome of DAIR were analyzed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 1 - 1
1 Oct 2022
Simon S Frank BJH Aichmair A Dominkus M Mitterer JA Hartmann S Kasparek M Hofstätter J
Full Access

Purpose

Unexpected-positive-intraoperative-cultures (UPIC) in presumed aseptic revision-total-knee-arthroplasties (rTKA) are common, and the clinical significance is not entirely clear. In contrast, in some presumably septic rTKA, an identification of an underlying pathogen was not possible, so called unexpected-negative-intraoperative-cultures (UNIC). The purpose of this study was to evaluate alpha defensin (AD) levels in these patient populations.

Methods

In this retrospective analysis of our prospectively maintained biobank, we evaluated synovial AD levels from 143 rTKAs. The 2018-Musculoskeletal Infection Society score (MSIS) was used to define our study groups. Overall, 20 rTKA with UPIC with a minimum of one positive intraoperative culture with MSIS 2-≥6 and 14 UNIC samples with MSIS≥6 were compared to 34 septic culture-positive samples (MSIS ≥6) and 75 aseptic culture-negative (MSIS 0–1) rTKAs. Moreover, we compared the performance of both AD-lateral-flow-assay (ADLF) and an enzyme-linked-immunosorbent-assay (ELISA) to test the presence of AD in native and centrifuged synovial fluid. Concentration of AD determined by ELISA and ADLF methods, as well as microbiological, and histopathological results, serum and synovial parameters along with demographic factors were considered.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 54 - 54
1 Oct 2022
Mitterer JA Frank BJ Gardete-Hartmann S Panzenboek LF Simon S Krepler P Hofstaetter JG
Full Access

Aim

In severe cases of postoperative spinal implant infections (PSII) multiple revision surgeries may be needed. Little is known if changes of the microbiological spectrum and antibiotic resistance pattern occur between revision surgeries. Therefore, the aim of this study was to analyze the microbiological spectrum and antibiotic resistance pattern in patients with multiple revision surgeries for the treatment of PSII. Furthermore, changes of the microbiological spectrum, distribution of mono vs. polymicrobial infections, and changes of the antimicrobial resistance profile in persistent microorganisms were evaluated.

Method

A retrospective analysis of a prospectively maintained single center spine infection database was performed with a minimum follow-up of 3 years. Between 01/2011 and 12/2018, 103 patients underwent 248 revision surgeries for the treatment of PSII. Overall, 20 patients (6 male/14 female) underwent 82 revisions for PSII (median 3; range 2–12). There were 55/82 (67.1%) procedures with a positive microbiological result. Microbiological analysis was performed on tissue and implant sonication fluid. Changes in microbial spectrum and antibiotic resistance pattern between surgeries were evaluated using Chi-Square and Fisher's exact test.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 27 - 27
1 Dec 2021
Simon S Frank BJH Hinterhuber L Reitsamer M Schwarz GM Aichmair A Dominkus M Söderquist B Hofstaetter JG
Full Access

Aim

Dalbavancin is a novel second-generation lipoglycopeptide antibiotic with strong activity against many gram-positive bacteria and a prolonged half-life of 6–11 days. This allows a once-a-week intravenous application and therefore an outpatient intravenous therapy. Currently, only little is known about the use of Dalbavancin in Periprosthetic joint infection (PJI). The aim of this retrospective study, was to compare the outcome of hip and knee periprosthetic joint infections (PJI) in patients who received dalbavancin (DAL) with patients which was treated by standard of care antimicrobial agents (SoC).

Methods

Between 02/2017 and 02/2020 a total of 89 (42 male/47 female) patients with PJI of the hip 56/89 (62.9%) and knee 33/89 (37.1%) who received at least one dosage of Dalbavancin were included. A 1:1 propensity-score (PS) matching between the DAL-group (n=89) and the SoC-group (n=89) was performed, using defined demographic covariates such as body-mass-index, age, sex, causative pathogens, knee or hip joint and infection after primary or revision surgery, surgical site infections, Charlson-comorbidity index and the types of infection (acute, late acute and chronic). Patient's demographics were analysed by our prospectively maintained institutional arthroplasty registry and PJI database. We analysed the outcome of the included patients evaluate the re-infection and re-revision rate and gave details about surgical management and the type of PJI with a minimum follow-up of one year.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 7 - 7
1 Dec 2021
Frank BJH Simon S Aichmair A Dominkus M Schwarz GM Hofstaetter JG
Full Access

Aim

Little is known about microbiological spectrum and resistance patterns as well as the clinical outcome in patients who undergo a repeat first stage procedure as part of a 2-stage revision arthroplasty for the treatment of periprosthetic hip and knee joint infections.

Methods

Between 2011 and 2019, a total of 327 2-stage revision arthroplasties were performed on 312 patients with PJI of the knee and hip at our institution. We performed a retrospective analysis of all patients, who underwent a repeat first stage procedure regarding re-revision rate, host factors, culture negative and positive stages, monomicrobial and polymicrobial infections as well as microbiological spectrum and antimicrobial resistance patterns.