The purpose of this study was to assess the variability in implant position between sides in patients who underwent staged, bilateral THA and whether variation from one side to the other affected patient-reported outcomes. A retrospective review was conducted on 207 patients who underwent staged, bilateral THA by the same surgeon from 2017–2022. Leg length, acetabular height, cup version, and coronal and sagittal stem angles were assessed radiographically and compared to the contralateral THA. Surgical approach and technology utilization were further assessed for their impact on variability. Linear regression was used to model the relationship between side-to-side variability and patient-reported outcome measures (PROMS). Between sides, mean radiographic leg length varied by 4.6mm (0.0–21.2), acetabular height varied by 3.3mm (0.0–13.7), anteversion varied by 8.2° (0.0 to 28.7), coronal stem alignment varied by 1.1° (0.0 to 6.9), and sagittal angulation varied by 2.3° (0.0 to 10.5). The anterior approach resulted in more variability in stem angle position in both the coronal (1.3° vs. 1.0°, p=0.036) and sagittal planes (2.8° vs. 2.0° p=0.012) compared to the posterior approach. The posterior approach generally led to more anteversion than the anterior approach. Use of robotics or navigation for acetabular positioning did not increase side-to-side variability in cup-related position or leg length. Despite considerable side-to-side variability, Hip dysfunction and osteoarthritis outcome scores (HOOS JR) were not affected by higher levels of position inconsistency. Staged, bilateral THA results in considerable variability in component position between sides. The anterior approach leads to more side-to-side variability in sagittal stem angle and cup anteversion than the posterior approach. Navigation and robotics do not improve the consistency of component position in bilateral THA. Variation in implant position was not associated with differences in PROMs, suggesting that despite variability, patients can tolerate these differences between sides.
Total hip arthroplasty (THA) is a common procedure to address pain and enhance function in hip disorders such as osteoarthritis. Despite its success, postoperative patient recovery exhibits considerable heterogeneity. This study aimed to investigate whether patients follow distinct pain trajectories following THA and identify the patient characteristics linked to suboptimal trajectories. This retrospective cohort study analyzed THA patients at a large academic centre (NYU Langone Orthopedic Hospital, New York, USA) from January 2018 to January 2023, who completed the Patient-Reported Outcomes Measurement Information System (PROMIS) pain intensity questionnaires, collected preoperatively at one-, three-, six-, 12-, and 24-month follow-up times. Growth mixture modelling (GMM) was used to model the trajectories. Optimal model fit was determined by Bayesian information criterion (BIC), Vuong-Lo-Mendell-Rubin likelihood ratio test (VLMR-LRT), posterior probabilities, and entropy values. Association between trajectory groups and patient characteristics were measured by multinomial logistic regression using the three-step approach.Aims
Methods
United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.Aims
Methods
Patients with a high comorbidity burden (high-risk) can achieve similar improvements in quality of life compared to low-risk patients, but greater morbidity may deter surgeons from operating on these patients. Whether surgeon volume influences THA outcomes in high-risk patients has not been investigated. This study aimed to compare complication rates and implant survivorship in high-risk patients operated on by high volume (HV) and non-HV THA surgeons. Patients with Charlson Comorbidity Index ≥ 5 and American Society of Anesthesiologist Classification of 3 or 4 undergoing primary, elective THA between 2013 and 2021 were retrospectively reviewed. Patients were separated into groups based on whether they were operated on by a HV surgeon (defined as the top 25% of surgeons at our institution by number of primary THAs per year) or a non-HV surgeon. Groups were propensity matched 1:1 to control for demographic variables. A total of 1,134 patients were included in the matched analysis. Ninety day readmissions and revisions were compared between groups, and Kaplan-Meier analysis was used to evaluate implant survivorship within the follow-up period. Years of experience were comparable between Non-HV and HV surgeons (p=0.733). The HV group had significantly shorter surgical times (p<0.001), and shorter length of stay (p=0.009) compared to the Non-HV group. The HV group also had significantly fewer 90-day readmissions (p=0.030), all-cause revisions (p=0.023) and septic revisions (p=0.020) compared to the non-HV group at latest follow-up. The HV group had significantly greater freedom from all-cause (p=0.023) and septic revision (p=0.020) compared to the non-HV group. High-risk THA patients have fewer 90-day readmissions, all-cause revisions, septic revisions, as well as shorter length of stay when treated by HV surgeons. THA candidates with a high comorbidity burden may benefit from referral to high-volume surgeons to reduce procedural risk and improve postoperative outcomes.
Revision total knee arthroplasty (rTKA) is a technically challenging and costly procedure. It is well-documented that primary TKA (pTKA) have better survivorship than rTKA; however, we were unable to identify any studies explicitly investigating previous rTKA as a risk factor for failure following rTKA. The purpose of this study is to compare the outcomes following rTKA between patients undergoing index rTKA and those who had been previously revised. This retrospective, observational study reviewed patients who underwent unilateral, aseptic rTKA at an academic orthopaedic speciality hospital between June 2011 and April 2020 with > one-year of follow-up. Patients were dichotomized based on whether this was their first revision procedure or not. Patient demographics, surgical factors, postoperative outcomes, and re-revision rates were compared between the groups.Aims
Methods
Although readmission has historically been of primary interest, emergency department (ED) visits are increasingly a point of focus and can serve as a potentially unnecessary gateway to readmission. This study aims to analyze the difference between primary and revision total joint arthroplasty (TJA) cases in terms of the rate and reasons associated with 90-day ED visits. We retrospectively reviewed all patients who underwent TJA from 2011 to 2021 at a single, large, tertiary urban institution. Patients were separated into two cohorts based on whether they underwent primary or revision TJA (rTJA). Outcomes of interest included ED visit within 90-days of surgery, as well as reasons for ED visit and readmission rate. Multivariable logistic regressions were performed to compare the two groups while accounting for all statistically significant demographic variables.Aims
Methods
Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (Aims
Methods
The Forgotten Joint Score-12 (FJS-12) is a validated patient-reported outcome measure (PROM) tool designed to assess artificial prosthesis awareness during daily activities following total hip arthroplasty (THA). The patient-acceptable symptom state (PASS) is the minimum cut-off value that corresponds to a patient’s satisfactory state-of-health. Despite the validity and reliability of the FJS-12 having been previously demonstrated, the PASS has yet to be clearly defined. This study aims to define the PASS of the FJS-12 following primary THA. We retrospectively reviewed all patients who underwent primary elective THA from 2019 to 2020, and answered both the FJS-12 and the Hip Disability and Osteoarthritis Outcome Score, Joint Replacement (HOOS, JR) questionnaires one-year postoperatively. HOOS, JR score was used as the anchor to estimate the PASS of FJS-12. Two statistical methods were employed: the receiver operating characteristic (ROC) curve point, which maximized the Youden index; and 75th percentile of the cumulative percentage curve of patients who had the HOOS, JR score difference larger than the cut-off value.Aims
Methods
In computer simulations, the shape of the range of motion (ROM) of a stem with a cylindrical neck design will be a perfect cone. However, many modern stems have rectangular/oval-shaped necks. We hypothesized that the rectangular/oval stem neck will affect the shape of the ROM and the prosthetic impingement. Total hip arthroplasty (THA) motion while standing and sitting was simulated using a MATLAB model (one stem with a cylindrical neck and one stem with a rectangular neck). The primary predictor was the geometry of the neck (cylindrical vs rectangular) and the main outcome was the shape of ROM based on the prosthetic impingement between the neck and the liner. The secondary outcome was the difference in the ROM provided by each neck geometry and the effect of the pelvic tilt on this ROM. Multiple regression was used to analyze the data.Aims
Methods
As our population ages, the number of octogenarians who will require a total hip arthroplasty (THA) rises. In a value-based system where operative outcomes are linked to hospital payments, it is necessary to assess the outcomes in this population. The purpose of this study was to compare outcomes of elective, primary THA in patients ≥ 80 years old to those aged < 80. A retrospective review of 10,251 consecutive THA cases from 2011 to 2019 was conducted. Patient-reported outcome (PRO) scores (Hip disability and Osteoarthritis Outcome Score (HOOS)), as well as demographic, readmission, and complication data, were collected.Aims
Methods
Re-revision due to instability and dislocation can occur in up to 1 in 4 cases following revision total hip arthroplasty (THA). Optimal placement of components during revision surgery is thus critical in avoiding re-revision. Computer-assisted navigation has been shown to improve the accuracy and precision of component placement in primary THA; however, its role in revision surgery is less well documented. The purpose of our study was to evaluate the effect of computer-assisted navigation on component placement in revision total hip arthroplasty, as compared with conventional surgery. To examine the effect of navigation on acetabular component placement in revision THA, we retrospectively reviewed data from a multi-centre cohort of 128 patients having undergone revision THA between March 2017 and January 2019. An imageless computer navigation device (Intellijoint HIP®, Intellijoint Surgical, Kitchener, ON, Canada) was utilized in 69 surgeries and conventional methods were used in 59 surgeries. Acetabular component placement (anteversion, inclination) and the proportion of acetabular components placed in a functional safe zone (40° inclination/20° anteversion) were compared between navigation assisted and conventional THA groups.Introduction
Methods
Sagittal pelvic tilt (SPT) can change with spinal pathologies and fusion. Change in the SPT can result in impingement and hip instability. Our aim was to determine the magnitude of the SPT change for hip instability to test the hypothesis that the magnitude of SPT change for hip instability is less than 10° and it is not similar for different hip motions. Hip implant motions were simulated in standing, sitting, sit-to-stand, bending forward, squatting and pivoting in Matlab software. When prosthetic head and liner are parallel, femoral head dome (FHD) faces the center of the liner. FHD moves toward the edge of the liner with hip motions. The maximum distance between the FHD and the center in each motion was calculated and analyzed. To make the results more reliable and to consider the possibility of bony impingement, when the FHD approached 90% of the distance between the liner-center and liner-edge, we considered the hip “in danger for dislocation”. The implant orientations and SPT were modified by 1-degree increments and we used linear regression with receiver operating characteristic (ROC) curve and area under the curve (AUC) to determine the magnitude of SPT change that could cause instability.Introduction
Methods
There is debate regarding whether the use of computer-assisted technology, such as navigation and robotics, has any benefit on clinical or patient reported outcomes following total knee arthroplasty (TKA). This study aims to report on the association between intraoperative use of technology and outcomes in patients who underwent primary TKA. We retrospectively reviewed 7,096 patients who underwent primary TKA from 2016–2020. Patients were stratified depending on the technology utilized intraoperatively: navigation, robotics, or no technology. Patient demographics, clinical data, Forgotten Joint Score-12 (FJS), and Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) were collected at various time points up to 1-year follow-up. Demographic differences were assessed with chi-square and ANOVA tests. Clinical data and mean FJS and KOOS, JR scores were compared using univariate ANCOVA, controlling for demographic differences.Introduction
Methods
The use of technology, such as navigation and robotic systems, may improve the accuracy of component positioning in total hip arthroplasty (THA) but its impact on patient reported outcomes measures (PROMs) remains unclear. This study aims to identify the association between intraoperative use of technology and patient reported outcomes measures (PROMs) in patients who underwent primary total hip arthroplasty (THA). We retrospectively reviewed patients who underwent primary THA between 2016 and 2020 and answered a post-operative PROM questionnaire. Patients were separated into three groups depending on the technology utilized intraoperatively: navigation, robotics, or no technology (i.e. manual THA. The Forgotten Joint Score (FJS-12) and Hip Disability and Osteoarthritis Outcome Score, Joint Replacement (HOOS, JR) were collected at various time points (FJS: 3m, 1y, and 2y; HOOS, JR: pre-operatively, 3m, and 1y). Demographic differences were assessed with chi-square and ANOVA. Mean scores between all groups were compared using univariate ANCOVA, controlling for observed demographic differences.Introduction
Methods
Venous thromboembolism (VTE), defined as either pulmonary embolism (PE) or deep venous thrombosis (DVT), is a rare, but serious complication following total hip arthroplasty (THA). Current VTE guidelines recommend pharmacologic agents with or without intermittent pneumatic compression devices (IPCDs). At our institution, both 81mg aspirin (ASA) twice a day (BID) and portable IPCDs were prescribed to THA patients at standard risk for VTE. The aim of this study is to determine if discontinuing the use of portable outpatient IPCDs is safe and does not increase the rate of VTE in patients undergoing THA. A retrospective review of 1,825 consecutive THA cases was conducted identifying patients with a VTE 90-days postoperatively. Patients were divided into two separate consecutive cohorts. Cohort one consisted of THA patients who received outpatient IPCDs for a period of 14 days (control). Cohort two consisted of THA patients without outpatient IPCDs (experimental). Patients were non-randomized to 81mg ASA BID for 28 days for VTE chemoprophylaxis. An interim power analysis was performed to determine the proper sample size.Introduction
Methods
Previous studies have demonstrated that higher volume hospitals have better outcomes following revision total knee arthroplasty (rTKA), in current literature there are no reports investigating the effect of surgeon volume. The purpose of this study is to investigate if patients of high-volume revision surgeons have better outcomes following rTKA as compared to patients of low volume surgeons. This retrospective observational analysis examined the rTKA database at a large urban academic medical center for aseptic, unilateral rTKA between January 2016 and March 2019 with at least 1-year of follow-up. Surgeon operative volume during the same time period was evaluated. Surgeons who performed at least 18 aseptic rTKA per year were considered Introduction
Methods
The COVID-19 pandemic led to a swift adoption of telehealth in orthopedic surgery. The purpose of this study was to analyze patient and surgeon satisfaction with a rapid expansion of telehealth use during COVID-19 pandemic within the division of adult reconstructive surgery at a major urban academic hospital. 334 hip and knee arthroplasty patients who completed a telemedicine visit from March 30th, 2020 through April 30th, 2020 were sent a 14-question survey. Eight adult reconstructive surgeons who used telemedicine were sent a separate 14-question survey at the end of the study period. Factors influencing patient satisfaction were determined using univariate and multivariate ordinal logistic regression modeling.Introduction
Methods
Previous reports have investigated the correlation between time to revision hip arthroplasty (rTHA) and reason for revision, but little is known regarding the impact of timing on outcomes following rTHA. The purpose of this study is to evaluate the effect of time to rTHA on both indication and outcomes of rTHA. This retrospective observational study reviewed patients who underwent unilateral, aseptic rTHA at an academic orthopedic specialty hospital between January 2016 and April 2019 with at least 1-year of follow-up. Patients were early revisions if they were revised within 2 years of primary THA (pTHA) or late revisions if revised after greater than 2 years. Patient demographics, surgical factors, and post-operative outcomes were compared between the groups. Post-hoc power analysis was performed (1-β=0.991).Introduction
Methods
The effect of using thicker liners in primary total knee arthroplasty (TKA) on functional outcomes and aseptic failure rates remains largely unknown. As such, we devised a multicenter study to assess both the clinical outcomes and survivorship of thick vs thin liners after primary TKA. A search of our institutional databases was performed for patients having undergone bilateral (simultaneous or staged) primary TKA with similar preoperative and surgical characteristics between both sides. Two cohorts were created: thick liners and thin liners. Outcomes collected were as follows: change in Knee Society Score (DKSS), change in range of motion, and aseptic revision. Ad hoc power analysis was performed for DKSS (α ¼ 0.05; power ¼ 80%). Differences between cohorts were assessed.Introduction
Methods
The Comprehensive Care for Joint Replacement (CJR) model was implemented in April-2016 to standardize cost and improve quality of care for two of the most commonly billed inpatient procedures for Medicare patients, total knee and total hip arthroplasty. The purpose of this study is to compare one institution's predicted savings and losses under the CJR model with actual savings and losses after two years of implementation and discuss new methods to maintain savings. Using our institution's data, we calculated the mean cost per episode of care. We calculated the percent reduction in target price and percent savings or losses per case for the CJR and Bundle Payment Care Initiative (BPCI) for each Medicare Severity Diagnosis Related Group (MS-DRG) using mean cost per episode and CJR and BPCI target prices. We compared the target prices, annual savings, and losses per episode of care for both CJR and BPCI. All CJR savings, projected and actual, were computed by comparing CJR savings to that of 2018 BPCI savings.Background
Methods