Recently, some smart media devices including portable accelerometers have been used to measure objective physical activity (OPA) after total hip arthroplasty (THA). The aim of this study was to longitudinally assess OPA changes in patients who underwent THA using a compact triaxial accelerometer and to investigate the impact of this recovery process on patient-reported outcomes.

This prospective cohort study involved 163 consecutive patients who had unilateral osteoarthritis of the hip and were followed up for 12 months after THA. There were 132 women and 31 men with average age of 66 years. OPA was measured using a compact triaxial accelerometer preoperatively and at 1, 3, 6, and 12 months postoperatively. This study investigated the recovery process of OPA in four patient groups classified by the median of age and preoperative activity levels (younger and higher activity (YH), younger and lower activity (YL), older and higher activity (OH), and older and lower activity (OL)), and examined its impact on patient-reported outcomes, including forgotten joint score-12 (FJS-12).

The target period for regaining preoperative activity levels was approximately 3 months for patients with lower preoperative activity, and about 6 months for those with higher preoperative activity. The OPA at 12 months postoperatively was higher in the patients with higher preoperative activity levels than in those with lower preoperative activity levels. In patients with higher preoperative activity levels, FJS-12 scores significantly increased between 6 and 12 months postoperatively (p=0.018). FJS-12 at 12 months postoperatively was best in YH (81.7±18.9), followed by YL (73.5±22.9), OH (73.2±17.4), and OL (66.3±21.8).

Differences in the recovery process of postoperative activity levels impacted the duration required for improvement in FJS-12 scores. These results can serve as indicators for setting activity goals in patients undergoing THA.


Bone & Joint Research
Vol. 12, Issue 9 | Pages 590 - 597
20 Sep 2023
Uemura K Otake Y Takashima K Hamada H Imagama T Takao M Sakai T Sato Y Okada S Sugano N

Aims

This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images.

Methods

The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm3). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims

This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA).

Methods

We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 130 - 130
1 Apr 2019
Tamura K Takao M Hamada H Sakai T Sugano N
Full Access

Introduction

Most of patients with unilateral hip disease shows muscle volume atrophy of pelvis and thigh in the affected side because of pain and disuse, resulting in reduced muscle weakness and limping. However, it is unclear how the muscle atrophy correlated with muscle strength in the patient with hip disorders. A previous study have demonstrated that the volume of the gluteus medius correlated with the muscle strength by volumetric measurement using 3 dimensional computed tomography (3D-CT) data, however, muscles influence each other during motions and there is no reports focusing on the relationship between some major muscles of pelvis and thigh including gluteus maximus, gluteus medius, iliopsoas and quadriceps and muscle strength in several hip and knee motions. Therefore, the purpose of the present study is to evaluate the relationship between muscle volumetric atrophy of major muscles of pelvis and thigh and muscle strength in flexion, extension and abduction of hip joints and extension of knee joint before surgery in patients with unilateral hip disease.

Material and Methods

The subjects were 38 patients with unilateral hip osteoarthritis, who underwent hip joint surgery. They all underwent preoperative computed tomography (CT) for preoperative planning. There were 6 males and 32 females with average age 59.5 years old.

Before surgery, isometric muscle strength in hip flexion, hip extension, hip abduction and knee extension were measured using a hand held dynamometer (µTas F-1, ANIMA Japan).

Major muscles including gluteus maximus, gluteus medius, iliopsoas and quadriceps were automatically extracted from the preoperative CT using convolutional neural networks (CNN) and were corrected manually by the experienced surgeon.

The muscle volumetric atrophy ratio was defined as the ratio of muscle volume of the affected side to that of the unaffected side. The muscle weakness ratio was defined as the ratio of muscle strength of the affected side to that of the unaffected side.

The correlation coefficient between the muscle atrophy ratio and the muscle weakness ratio of each muscle were calculated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 73 - 73
1 Apr 2018
Kishimoto Y Ohkawara B Sakai T Ono Y Ishiguro N Docheva D Ohno K
Full Access

Introduction

Modulation of signaling pathways, which involves tendon development, regeneration, or homeostasis, is one of the potential modalities to facilitate proper regeneration of the injured tendon. Authors have previously reported that activation of Wnt/beta-catenin signaling suppressed the expression of tenogenic genes (i.e. Scleraxis (Scx), Mohawk (Mkx), Tenomodulin (Tnmd)) in rat primary tendon-derived cells (TDCs) and SCX-transduced human mesenchymal stem cells (hMSC-Scx cells), as a tendon progenitor cell line (kindly provided Dr. Docheva). The roles of TGF-beta signaling in tenogenesis have been elucidated. The purpose of the study was to evaluate the effect of TGF-beta signaling on tenogenic genes and relationship between both two signalings in rat TDCs and hMSC-Scx cells.

Materials and Methods


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 57 - 57
1 Jan 2018
Sugano N Hamada H Takao M Sakai T Nakamura N
Full Access

The purposes of this study were to review retrospectively the 10-year outcome of cementless total hip arthroplasty (THA) using an active robot system in the femoral canal preparation for an anatomic short stem and navigation in the cup placement through a mini incision posterior approach. We reviewed all patients who underwent THA with this procedure in 53 hips between 2004 and 2007. There were no intraoperative fracture nor navigation- or robotic-related complications. All implant sizes were same as planned ones. All cases were followed up at least two years and all implants showed bone ingrowth stable according to the Engh's criteria. After then, six patients died of unrelated causes. Two patients (three hips) could not come to the 10-year follow-up examination. The remaining 44 hips were followed for 10 to 12 years (11 years on average). There is no dislocation. The average JOA hip score improved from 48 preoperatively to 96 at the final examination. On the postoperative x-ray measurements, the average cup radiographic inclination was 39° and the radiographic anteversion was 14°. There was no stem which showed more than 2° of varus or valgus alignment. There was no case who showed more than 5mm of limb length discrepancy. Postoperative CT images of 38 hips were obtained at 2 weeks. After matching the coordinates of the pelvis and femur with the preoperative planning, we got very small differences in alignment parameters between the measured values and the planed ones. The difference differences between the plan and measured values were −0.1° in cup inclination, −1.4° in cup anteversion, stem 0.5° in coronal alignment, 0.6° in stem sagittal alignment, and −1.6° in stem anteversion, respectively. We conclude that our robotic femoral preparation for a short anatomical stem and navigated cup placement thru a mini-posterior approach was safe and feasible without affecting the accuracy of the procedure. There were no long term adverse effect of the procedure.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 23 - 23
1 Dec 2017
Sakai T Hamada H Murase T Takao M Yoshikawa H Sugano N
Full Access

The purpose of this experimental study was to elucidate the accuracy of neck-cut PSG setting, and femoral component implantation using neck-cut PSG in the THA through the anterolateral-approach relative to the preoperative planning goals, and to determine the usefulness of PSG compared with the procedure without PSG. A total of 32 hips from 16 fresh Caucasian cadaveric samples were used and classified into 4 groups: cementless anatomical stem implantation with wide-base-contact PSG (AWP: 8 hips, Fig.2); (2) cementless anatomical stem implantation with narrow-base-contact PSG (ANP: 8 hips, Fig.2); (3) cementless anatomical stem implantation without PSG (Control: 8 hips); and (4) cementless taper-wedge stem implantation with wide-base-contact PSG (TWP: 8 hips). The absolute error of PSG setting in the sagittal plane of the AWP group was significantly less than that of the ANP (p=0.003).THA with wide-base- contact PSG resulted in better alignment of the femoral component than THA without PSG or with narrow- base-contact PSG. Although the neck-cut PSG did not control the sagittal alignment of taper-wedge stem, the neck-cut PSG was effective to realise the preoperative coronal alignment and medial height for THA via the anterolateral approach regardless of the femoral component type.

For figures and tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 23 - 23
1 Mar 2017
Sugano N Nakahara I Hamada H Takao M Sakai T Ohzono K
Full Access

The purposes of this study were to review retrospectively the 25-year survival of cemented and cementless THA for hip dysplasia and to compare the effect of fixation methods on the long-term survival in patients with DDH. We retrospectively reviewed all patients with OA secondary to hip dysplasia treated with a cemented Bioceram hip system between 1981 and 1987, and a cementless cancellous metal Lübeck hip system between 1987 and 1991. The studied subjects were 76 hips of cemented THA (Group-C) and 57 hips of cementless THA (Group-UC). Both hip implants had a 28-mm alumina head on polyethylene articulation. The mean age at operation was 50.5 years (range, 36–60 years) in Group-C and 50.0 years (range, 29–60 years) in Group-UC. The survival at 25 years regarding any revision as the endpoint was 46% in Group-C and 76% in Group-UC. These difference was significant using Log-rank test (P=0.008). The cup survival at 25 years was 47% in Group-C and 83% in Group-UC (P= 0.0003). The stem survivals at 25 years were 95% in Group-C and 92% in Group-UC. (P= 0.416). Cementless THA in patients with DDH showed a higher survival rate at 25 years than cemented THA because of the excellent survival of the acetabular component without cement. We conclude that cementless THA with the cancellous metal Lübeck hip system led to better longevity at 25 years than cemented THA with the Bioceram in patients with OA secondary to DDH.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 39 - 39
1 Mar 2017
Takao M Ogawa T Yokota F Otake Y Hamada H Sakai T Sato Y Sugano N
Full Access

Introduction

Patients with hip osteoarthritis have a substantial loss of muscular strength in the affected limb compared to the healthy limb preoperatively, but there is very little quantitative information available on preoperative muscle atrophy and degeneration and their influence on postoperative quality of life (QOL) and the risk of falls. The purpose of the present study were two folds; to assess muscle atrophy and degeneration of pelvis and thigh of patients with unilateral hip osteoarthritis using computed tomography (CT) and to evaluate their impacts on postoperative QOL and the risk of falls.

Methods

We used preoperative CT data of 20 patients who underwent primary total hip arthroplasty. The following 17 muscles were segmented with our developed semi-automated segmentation method: iliacus, gluteus maximus, gluteus medius, gluteus minimus, rectus femoris, tensor facia lata, adductors, pectinus, piriformis, obturator externus, obturator internus, semimenbranosus, semitendinosus, vastus medialis and vastus lateralis/intermedius (Fig. 1). Volume and radiological density of each muscle were measured. The ratio of those of affected limb to healthy limb was calculated. At the latest follow-up, the WOMAC score was collected and a history of falls after surgery was asked. The average follow- up period was 6 years.

Comparison of the volume and radiological density of each muscle between affected and healthy limbs was performed using the Wilcoxon signed rank test. Correlations between the volume and radiological density of each muscle and each score of the WOMAC were evaluated with Spearman's correlation coefficient. The volume and radiological density of each muscle between patients with and without a history of falls were compared using Mann-Whitney U test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 56 - 56
1 Mar 2017
Uemura K Takao M Otake Y Koyama K Yokota F Hamada H Sakai T Sato Y Sugano N
Full Access

Background

Cup anteversion and inclination are important to avoid implant impingement and dislocation in total hip arthroplasty (THA). However, it is well known that functional cup anteversion and cup inclination also change as the pelvic sagittal inclination (PSI) changes, and many reports have been made to investigate the PSI in supine and standing positions. However, the maximum numbers of subjects studied are around 150 due to the requirement of considerable manual input in measuring the PSIs. Therefore, PSI in supine and standing positions were measured fully automatically with a computational method in a large cohort, and the factors which relate to the PSI change from supine to standing were analyzed in this study.

Methods

A total of 422 patients who underwent THA from 2011 to 2015 were the subjects of this study. There were 83 patients with primary OA, 274 patients with DDH derived secondary OA (DDH-OA), 48 patients with osteonecrosis, and 17 patients with rapidly destructive coxopathy (RDC). The median age of the patient was 61 (range; 15–87). Preoperative PSI in supine and standing positions were measured and the number of cases in which PSI changed more than 10° posteriorly were calculated. PSI in supine was measured as the angle between the anterior pelvic plane (APP) and the horizontal line of the body on the sagittal plane of APP, and PSI in standing was measured as the angle between the APP and the line perpendicular to the horizontal surface on the sagittal plane of APP (Fig. 1). The value was set positive if the pelvis was tilted anteriorly and was set negative if the pelvis tilted posteriorly. Type of hip disease, sex, and age were analyzed with multiple logistic regression analysis if they were related to PSI change of more than 10°. For accuracy verification, PSI in supine and standing were measured manually with the previous manual method in 100 cases and were compared with the automated system used in this study.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 24 - 24
1 Mar 2017
Sugano N Uemura K Ogawa T Hamada H Takao M Sakai T
Full Access

Although many distal fit and fill design cementless stems have shown a very good long term stable fixation, short proximal coated stems are recently increasing in their use with an expectation of less stress shielding and an ease of removal at revision surgery. We introduced an anatomic short stem made from titanium alloy with proximal plasma-spray titanium and hydroxyapatite coating (CentPillar, Stryker, Mahwah) in 2002. To evaluate a minimum 10-year outcome of the system in terms of fixation and stress shielding, we reviewed initial 100 consecutive cases operated by a single surgeon. There were 91 hips with osteoarthritis and 9 hips with osteonecrosis. There were 94 females and 6 males. Average age at operation was 58 years. The patients were followed up for an average of 11 years. Average JOA hip score improved significantly from 46.9 preoperatively to 96.7 at the final examination. There were no dislocation, or revision, or radiographic loosening. When we looked at the level of bone atrophy, 80% of cases showed no stress shielding below the lessor trochanter. We conclude that the CentPillar stem showed mild stress shielding due to short proximal bone ongrowth coating while keeping a long term good clinical score and radiographic stability.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 132 - 132
1 Mar 2017
Sakai T Koyanagi J Takao M Hamada H Sugano N Yoshikawa H Sugamoto K
Full Access

INTRODUCTION

The purpose of this study is to elucidate longitudinal kinematic changes of the hip joint during heels-down squatting after THA.

METHODS

66 patients with 76 primary cementless THAs using a CT-based navigation system were investigated using fluoroscopy. An acetabular component and an anatomical femoral component were used through the mini-posterior approach with repair of the short rotators. The femoral head size was 28mm (9 hips), 32mm (12 hips), 36mm (42 hips), and 40mm (12 hips). Longitudinal evaluation was performed at 3 months, 1 year, and 2≤ years postoperatively. Successive hip motion during heels-down squatting was recorded as serial digital radiographic images in a DICOM format using a flat panel detector. The coordinate system of the acetabular and femoral components based on the neutral standing position was defined. The images of the hip joint were matched to 3D-CAD models of the components using a2D/3D registration technique. In this system, the root mean square errors of rotation was less than 1.3°, and that of translation was less than 2.3 mm. We estimated changes in the relative angle of the femoral component to the acetabular component, which represented the hip ROM, and investigated the incidence of bony and/or prosthetic impingement during squatting (Fig.1). We also estimated changes in the pelvic posterior tilting angle (PA) using the acetabular component position change. In addition, when both components were positioned most closely during squatting, we estimated the minimum angle (MA) up to theoretical prosthetic impingement as the safety margin (Fig.2).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 62 - 62
1 Mar 2017
Ogawa T Miki H Hattori A Hamada H Takao M Sakai T Suzuki N Sugano N
Full Access

Introduction

Range of motion (ROM) simulation of the hip is useful to understand the maximum impingement free ROM in total hip arthroplasty (THA). In spite of a complex multi-directional movement of the hip in daily life, most of the previous reports have evaluated the ROM only in specific directions such as flexion-extension, abduction-adduction, and internal - external rotation at 0° or 90° of hip flexion. Therefore, we developed ROM simulation software (THA analyzer) to measure impingement free ROM in any positions of the hip. Recent designs of the hip implants give a wider ROM by increasing the head diameter and then, bone to bone impingement can be a ROM limit factor particularly in a combination of deep flexion, adduction and internal rotation of the hip. Therefore, the purpose of this study were to observe an individual variation in the pattern of the bone impingement ROM in normal hip bone models using this software, to classify the bone impingement ROM mapping types and to clarify the factors affecting the bone impingement type.

Methods

The subjects were 15 normal hips of 15 patients. Three dimensional surface models of the pelvis and femur were reconstructed from Computer tomography (CT) images. We performed virtual hip implantation with the same center of rotation, femoral offset, and leg length as the original hips. Subsequently, we created the ROM mapping until bone impingement using THA analyzer. We measured the following factors influenced on the bone impingement map patterns; the neck shaft angle, the femoral offset, femoral anteversion, pelvic tilt, acetabular anteversion, sharp angle, and CE angle. These factors were compared between the two groups. Statistical analysis was performed with Mann-Whitney U test, and statistical significance was set at P<0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 97 - 97
1 May 2016
Uemura K Takao M Sakai T Nishii T Sugano N
Full Access

Introduction

In total hip arthroplasty (THA), it is important to define the coordinate system of the pelvis and femur for standardization in measuring the implant alignment. A coronal plane of the pelvis (functional pelvic coordinates) in supine position has been recommended as the pelvic coordinates for cup orientation and an anatomical plane of the femur (posterior condylar plane: PCP) is widely used as the femoral coordinates to measure stem or femoral anteversion. It has been reported that the pelvic sagittal tilt in supine does not change a lot after THA. However, changes in the axial rotation of the posterior condylar plane after THA have not been well studied. If the horizontal tilt of PCP of the femur in a resting position changes a lot after THA, the combined anteversion theory cannot be functional. Therefore, we evaluated the angulation changes of the posterior condylar plane after THA and analyzed the related factors by using CT images.

Methods

Forty patients (5 men and 35 women, mean age 58 years) with hip osteoarthritis who had undergone THA were the subjects of this study. CT images used for measurements were taken preoperatively (preop-CT) and 3 weeks after THA (postop-CT), and more than 2 years after THA (2nd postop-CT).

Measurements were done on the reconstructed CT images using 3D viewer software. The axial rotation of the femur was measured as the angle between the posterior condylar line (PCL) and a line through the bilateral anterior superior iliac spines. To analyze the factors relating to the rotational change of the femur, change in femoral anteversion, leg length, and leg medialization after THA were also measured. Surgical approach (posterolateral: 32 cases, direct anterior: 8 cases) was also evaluated as a factor relating to the rotational change.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 56 - 56
1 May 2016
Sugano N Takao M Sakai T Nishii T Ohzono K
Full Access

Introduction

Metal on metal hip resurfacing (MoM HR) is attractive for young active patients. Patients with osteonecrosis of the femoral head (ONFH) are relatively young. HR can be an option of treatment, however, long-term stability of the femoral component is a concern because of the necrotic lesion in the femoral head. There is also a concern of ARMD for MoM implants. The purpose of this study is review a 10 year outcome of a consecutive patients with ONFH who underwent MoM HR.

Methods

The subjects of this study were 30 hips of 26 patients with ONFH who underwent HR between 1998 and 2004. There were 21 hips of 18 males and 9 hips of 8 females. The average age at operation was 40 years (range, 20–63 years). 19 ONFHs were induced by steroid and 11 ONFHs were alcohol related. According to the Japanese Investigation Committee classification, there were 8 hips with Type C1 and 22 hips with Type C2. There were 16 hips in stage 3A, 7 hips in Stage 3B, and 7 hips in Stage 4. Operation was performed through a posterior approach. A fragile necrotic bone was curettage thoroughly and the defect was filled with cement.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 94 - 94
1 May 2016
Ogawa T Takao M Sakai T Nishii T Sugano N
Full Access

Introduction

The incidence of dislocation after total hip arthroplasty (THA) was reported to be 0.5 to 10% in primary THA and 10 to 25 % in revision THA. The main causes of instability after THA were reported to be implant malalignment and inappropriate soft tissue tension. However, there was no study about quantitative data of soft tissue tension of unstable THA. The purpose of this study is to clarify the features of soft tissue tension of unstable THA in comparison to stable THA.

Methods

The subjects were 15 patients with 15 THAs who had developed recurrent dislocation after primary THA. Thirty four patients with 37 THAs who developed no dislocation for one year after surgery were recruited as a stable THA group. In both group, all THAs were performed through posterolateral approach. In order to assess the soft tissue tension of THA, we recorded antero-posterior radiographs of the hips while applying distal traction to the leg with traction forces of 20?, 30%, 40% of body weight (BW). The distance of separation of the head and the cup after traction was measured under correction of magnification. Nine of 15 THAs in the unstable THA group and 32 of 37 THAs in the stable THA group were unilateral involvement. In the hips with unilateral involvement, the femoral offset difference between the healthy hip and the reconstructed hip were evaluated. Statistical analysis was performed with χ2 testand Mann-Whitney U test, and statistical significance was set at P<0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 37 - 37
1 Feb 2016
Hamada H Takao M Uemura K Sakai T Nishii T Sugano N
Full Access

Rotational acetabular osteotomy (RAO) for developmental dysplasia of the hip (DDH) may not restore normal hip range of motion (ROM) due to the inherent deformity of the hip and it may lead to femoro-acetabular impingement. The purpose of this study was to investigate morphological factors of the pelvis and femur influencing on simulated ROM after RAO with a fixed target for femoral head coverage. We retrospectively reviewed CT images of 52 DDHs with an average lateral centre edge angle (CEA) of 7.9° (−12° to 19°). After virtual RAO with 30° of lateral CEA and 55° of anterior CEA producing femoral head coverage similar to that of the normal hips, we measured simulated flexion ROM using pelvic and femoral computer models reconstructed from the CT images. Pelvic sagittal inclination, acetabular anteversion, lateral CEA, femoral neck anteversion, femoral neck shaft angle (FNSA), alpha angle and the position of the anterior inferior iliac spine (AIIS) were investigated as morphological factor. When the most prominent point of the AIIS existed more distally than the cranial tip of the acetabular joint line in a lateral view of the pelvis model in supine position, the subjects were defined as AIIS-Type1; the remaining subjects were defined as Type 2. There were 10 hips with Type 1 and 42 hips with Type 2 AIIS. The Kappa value of inter-observer reproducibility to classify AIIS was 0.82. Multiple regression analyses were performed to analyse the relationship between ROM and the morphological parameters. We also analysed the relationship between the probability of flexion ROM being less than 110° and the factors which influenced on flexion ROM. FNSA and AIIS-Type independently influenced on simulated flexion ROM after RAO (standard regression coefficient: −0.51 and 0.37, respectively. p&lt; 0.001). The multiple correlation coefficient was 0.68. Flexion ROM after RAO with a fixed femoral head coverage similar to that of the normal hips ranged from 95° to 141° with an average of 121°±8°. The probability of ROM being less than 110° was significantly higher in subjects with AIIS-Type 1 than in those with Type 2 (odds ratio: 13.3, p&lt;0.01). It was also significantly higher in subjects with more than 135° of FNSA than in those with less than 135° of FNSA (odds ratio: 9.5, p&lt;0.05). FNSA and the type of AIIS influenced on flexion ROM after RAO with approximately 40° of variation in spite of a fixed target for femoral head coverage. A large FNSA and a distal positioning of AIIS were independently associated with smaller flexion ROM after RAO.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 48 - 48
1 Feb 2016
Takao M Nishii T Sakai T Yoshikawa H Sugano N
Full Access

Introduction

Inappropriate soft tissue tension around an artificial hip is regarded as one cause of dislocation or abductor muscle weakness. It has been considered that restoration of leg offset is important to optimise soft tissue tension in THA, while it is unclear what factors determine soft tissue tension around artificial hip joints. The purpose of the present study was to assess how postoperative leg offset influence the soft tissue tension around artificial hip joints.

Materials and Methods

The subjects were 89 consecutive patients who underwent mini-incision THA using a navigation system through antero-lateral or postero-lateral approach. Soft tissue tension was measured by applying traction amounting to 40% of body weight with the joint positioned at 0°, 15°, 30°, and 45° of flexion. The distance of separation between the head and the cup was measured using the navigation system.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 97 - 97
1 Jan 2016
Ogawa T Takao M Sakai T Nishii T Sugano N
Full Access

Puropose

Three-dimensional (3D) templating based on computed tomography (CT) in total hip arthroplasty improves the accuracy of implant size. However, even when using 3D-CT preoperative planning, getting the concordance rate between planned and actual sizes to reach 100% is not easy. To increase the concordance rate, it is important to analyze the causes of mismatch; however, no such studies have been reported. This study had the following two purposes: to clarify the concordance rate in implant size between 3D-CT preoperative planning and actual size; and to analyze risk factors for mismatch.

Materials and Methods

A single surgeon performed 149 THAs using Trident Cup and Centpillar Stem (Stryker) with CT-based navigation between September 2008 and August 2011. Minimal follow-up was 2 years. Patients with incomplete postoperative CT were excluded from this study. Based on these criteria, the study examined 124 hips in 111 patients (mean age, 60 years, mean BMI 23.2 kg/m2). The preoperative diagnosis was primary osteoarthritis in 8 hips, secondary osteoarthritis in 102 hips, osteonecrosis in 9 hips, rapidly destructive coxopathy in 4 hips and rheumatoid arthritis in 1 hip. We compared cup and stem sizes between preoperative planning and intraoperatively used components. Radiological evaluations were cortical index and canal flare index on preoperative X-rays. We evaluated preoperative planning and postoperative components for cup orientation, cup position, and stem alignment (anteversion, flexion and varus angle) on the CT-navigation system. Fixation of the stem was evaluated by X-ray radiography at 2 years postoperatively according to Engh's criteria. Statistical analysis was performed with the Mann-Whitney U test, and values of P<0.05 were considered statistically significant.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 106 - 106
1 Jan 2016
Takao TKM Sakai T Nishii T Sugano N
Full Access

Femoral head diameters in THA have been increasing due to good long-term outcomes of 1st generation HXLP cups. Furthermore, some 2nd generation HXLP cups allow 36mm or larger heads. However, larger femoral head diameters increase the frictional torque and may lead to early cup migration and loosening. And there is a concern that larger head diameters and reduced liner thickness may increase polyethylene wear. In this study, we compared early acetabular component migration and wear rates between a group of larger heads using a 2nd generation HXLP and a group smaller heads using a 1st generation HXLP.

The larger head group comprising 30 hips underwent THA between February 2010 and March 2011 with the use of a sequentially cross-linked polyethylene liner (X3). 30 patients were included in this study (30 women). Their mean age was 59.3years; mean weight was 53.6kg. Trident HA-coated cementless cups were used and the sizes ranged from 46mm to 56mm (mean 50.5mm). The head diameters were 36mm in 23hips, 40mm in 5 hips, and 44mm in 2hips. All X3 liners were 5.9mm or less in thickness.

A control group was selected from a previous case series that had undergo THA between July 2007 and January 2008 using a 1st generation HXLP liner (Crossfire) by matching age and sex. Therefore 30 patients were included in this study (30 women) too. Their mean age was 60.0 years; mean weight was 55.5kg. The same Trident cups were used and the sizes ranged from 46mm to 56mm (mean 49.5mm). The head diameters were 26mm in 19hips and 32mm in 11hips. The liner thicknesses were 7.8mm or more.

All hips had standardized anteroposterior pelvic digital radiographs performed postoperatively and cup migration was measured on digital radiographs at the immediate postoperative period and two year using EBRA-CUP software. We analyzed horizontal and vertical cup migration distance and the difference in cup anteversion and inclination angle at two years. Additionally, total head penetrarion and polyethylene liner volumetric wear rates were measured using a computer-assited method with PolyWear software.

The larger head group revealed an average of 0.48mm of horizontal migration, 0.75mm of vertical migration, 0.19degree of inclination change, and 1.26 degrees of anteversion change. The control group showed an average of 0.63mm of horizontal migration, 0.36mm of vertical migration, 0.07 degree of inclination change, and 0.88 degree of anteversion change. Based on the EBRA-CUP measurements, there were no cases of significant early loosening which was indicated by more than 1mm of migration, more than 2.5 degree of inclination change, or more than 3.3 degree of anteversion change.

The liner penetration rates were 0.388±0.192mm/yr in the large head group and 0.362±0.178mm/yr in the control group. The difference was not significant (p=0.64.) The volumetric wear rates were 42.8±27.9mm⁁3/yr in the large head group and 42.0±33.0mm⁁3/yr in the control group. Again, the difference was not significant (p=0.94).

No significant early cup migration or increased wear rate were detected in THA with the sequentially cross-linked polyethylene liner and 36mm or large heads at two years.