Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Bone & Joint Open
Vol. 1, Issue 5 | Pages 144 - 151
21 May 2020
Hussain ZB Shoman H Yau PWP Thevendran G Randelli F Zhang M Kocher MS Norrish A Khanduja V

Aims

The COVID-19 pandemic presents an unprecedented burden on global healthcare systems, and existing infrastructures must adapt and evolve to meet the challenge. With health systems reliant on the health of their workforce, the importance of protection against disease transmission in healthcare workers (HCWs) is clear. This study collated responses from several countries, provided by clinicians familiar with practice in each location, to identify areas of best practice and policy so as to build consensus of those measures that might reduce the risk of transmission of COVID-19 to HCWs at work.

Methods

A cross-sectional descriptive survey was designed with ten open and closed questions and sent to a representative sample. The sample was selected on a convenience basis of 27 senior surgeons, members of an international surgical society, who were all frontline workers in the COVID-19 pandemic. This study was reported according to the Standards for Reporting Qualitative Research (SRQR) checklist.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 106 - 106
1 May 2016
Pace F Randelli P Favilla S Brioschi M Maglione D Visentin O Randelli F
Full Access

Introduction

The dual mobility cup was introduced in the 1970s to allow extensive range of motion associated with great stability thanks to double articulation; the first between the head and polyethylene, the second between the polyethylene and the cup.

The original plan was to install a stainless-steel uncemented cup coated with a thin layer of alumina and a metal head of 22,2 mm with a polyethylene liner of first generation.

Long term follow-up case studies are cited in the literature showing excellent results in reducing dislocations; however wearing and aseptic loosening are noted.

The new dual-mobility cups, with reticular polyethylene and titanium and hydroxyapatite coating are proving as reliable as the older ones in terms of stability whilst they appear to be more durable.

Furthermore, cemented dual-mobility cups are available, these are the topic of this study. One of the most frequent complications in the major revisions of hip replacement is dislocation. This study summarises our experience gathered in the use of dual-mobility cups during revisions of complex cases (GIR III-IV femoral or acetabular).

Materials and Methods

Between July 2014 to March 2015, we have implanted 13 cemented cups with dual-mobility (Avantage® Biomet) each in different patients, who have undergone revision with severe ostheolysis (GIR III-IV femoral or acetabular). The mean age of patients was 71.5 years old (46 to 89).

Indications for revisions were: aseptic loosening in 7 patients (two at third surgery), recurrent dislocation in 3 patients, 1 septic loosening, 1 revision after spacer removal e 1 post-traumatic.

We used dual-mobility cup in revision surgery when implant stability could have been compromised due to difficult positioning of acetabular component in cases of walls defects or muscolar laxity. The patients have been evaluated clinically and radiographically.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 146 - 146
1 May 2016
Pace F Randelli F Favilla S Brioschi M Maglione D Galante C Visentin O Randelli P
Full Access

Introduction

Periprosthetic joint infection (PJI) is considered one of the most feared causes of implant failure, due to the difficulty in formulating a proper and timely diagnosis. In the diagnostic workup are often used test with a low specificity, such as the dosage of ESR and CRP, or sensitivity, such as cultures or the leukocyte count of the synovial fluid. Radiological investigations are expensive and unreliable to play a direct role in the diagnosis of PJI. The alpha-defensin is an antimicrobial peptide released by neutrophils in response to pathogens and it is an ideal biomarker for the diagnosis of PJI. It is now possible to verify the presence of alpha-defensin in periprosthetic synovial fluid with an ELISA (Synovasure® PJI, Zimmer) that provides results in 10 minutes, with a sensitivity of 97% and a specificity of 96%, without being affected by systemic inflammatory diseases or by the assumption of antibiotics. The purpose of this study is to assess the applicability and reliability of Synovasure® PJI, correlating its results with microbiological analyzes, laboratory tests and imaging studies of the patient.

Materials and Methods

Patients recruited are those who have undergone a previous total hip or knee arthroplasty where there is suspicion of PJI. The test can be performed either during surgery or during the diagnostic iter, through the execution of an arthrocentesis. The synovial fluid is partly used for Synovasure® PJI and partly put in culture for microbiological analyzes. Once ready, culture results are compared with the results of the test to get a confirmation of its reliability or reference to identify the microorganism responsible for PJI. These data are then compared, with laboratory tests and radiological investigations performed by the patient.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 494 - 494
1 Dec 2013
Pace F Randelli F Serrao L Banci L
Full Access

Introduction:

We present the mid-term results of our consecutive series of 155 hips treated with ASR XL Acetabular System (ASR-XL) for large-diameter metal-on-metal total hip arthroplasty and with DePuy ASR Hip Resurfacing System (ASR) for hip resurfacing.

Methods:

114 ASR-XL and 41 ASR were implanted between 2004 and 2008 in 145 patients (69 men and 76 women) with a mean age of 57 years. Twenty-one patients (23 hips) resulted lost to follow-up. All patients were recalled and monitored periodically with clinical, hematological and radiological evaluation. Average follow-up of the 155 hips was 72 months (1 to 104). The mean follow-up, excluding revised patients and those lost to follow-up, was up to 89 months.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 471 - 471
1 Dec 2013
Pace F Randelli F Favilla S Zaolino C Banci L
Full Access

Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear.

This study is the first with a long term follow-up for Meteasul, (Zimmer GmbH, Winterthur, Switzerland) metal on metal (MoM) hip replacement; in literature most of the studies have a mean follow-up of 7 years. Metasul showed better performances than other MoM couplings, with a low failure rate at long term follow-up and low revision rate for aspetic loosening.

The aim of the present study was to evaluate the long-term results of a series of Metasul implanted between January 1993 and July 1997. 145 cementless THAs with a 28 mm Metasul articulation were performed in 114 consecutive patients. Implant survivorship was calculated and clinical and radiographic evaluations were performed on 93 hips still available for follow-up at a mean of 19 years postoperatively (43 hips are dead or lost to FU, 29, 6%).

Nine hips (6.2%) were revised. The cumulative probability of survival of the overall implant at 19 years postoperatively with revision for any reason as the end point, was 0.937 (95% confidence interval, 0.888 to 0.985). The cumulative probability of survival of Metasul with revision for any reason as the end point, was 0.956 (95% confidence interval, 0.916 to 0.997).

Clinical outcome has been evaluated with modified Harris Hip Score for 93 hips with an average of 88.8 points.

Various degrees of radiolucencies and osteolysis were found proximally around the femoral components of 25 hips (20%).

Most of the patients has normal serum levels of metal ions (Co and Cr), and no cases of systemic toxicity has been reported.

Cementless Metasul THAs showed high probability of survival at 19 years postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 495 - 495
1 Dec 2013
Pace F Randelli F Serrao L Banci L
Full Access

Background

Previous studies have indicated poor outcomes and high complication rate in patients having revision of metal-on-metal (MoM) hip implants resulting from adverse local tissue reactions. Metal ions released by MoM bearings may potentially increase infection occurrence in patients with failed implants.

Questions/purposes

We reviewed all patients at our institution who sustained revision of a failed large-head metal-on-metal hip implant to determine if infection-related complications are associated with the elevation of serum metal ions concentration.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 310 - 310
1 Mar 2013
Randelli F Banci L Visentin O Aliprandi A Randelli G
Full Access

We present the mid-term results of our consecutive series of 155 hips treated with ASR extra-large (XL) Acetabular System (ASR XL) and with ASR Hip Resurfacing System (ASR). We reviewed the clinical records of patients with implanted ASR or ASR XL. All patients were recalled and invited to come to our hospital for a periodic clinical, hematological and radiological evaluation.114 ASR XL and 41 ASR were implanted between 2004 and 2008 in 145 patients (69 men and 76 women) with a mean age of 57 years. 21 patients (23 hips) were lost from follow-up. Average follow-up was 76 months (50 to 91). Up now 42 ASR implants have been revised (27.0%): revision involved 9 hips on 41 treated with resurfacing (21.9%) and 33 hips on 114 treated with XL total hip arthroplasty (28.9%). Main reasons for revision were aseptic loosening with or without metallosis in 23 hips (56%), infection in 3 hips (7%), recurrent dislocation in 1 hip (2%), periprosthetic fractures in 1 hip (2%), elevation of blood metal ion in 6 (14%), pain in 2 (5%), unknown in 6 (14%). The cumulative survival for our ASR implants series was 61.6% with revision for any reason as the end-point after a mean follow-up of 76 months. The cumulative survival with revision for any reason as the end-point for ASR and ASR XL were respectively 67.0% and 59.1%. For patients who did not undergone revision, the mean Harris hip score improved to 91 (57 to 100) at five years and the mean satisfaction after the operation was graded 4.4 in a score from 1 to 5. Periprosthetic osteolysis was not found around any unrevised hip. Average cup inclination was 48° for the functioning hips and 55° for the revised hips. Metal ions plasma concentration analysis was conducted in 83 patients (87 hips). Elevated metal ion concentration (>7 μg/l) was found in 39 patients (42 hips, 48%) with average plasma concentrations of 37.3 μg/l for chromium and 81.5 μg/l for cobalt. Lower metal ions levels (<7 μg/l) were found in 44 patients (45 hips, 52%) with average plasma concentrations of 1.2 μg/l for chromium and 1.9 μg/l for cobalt. Our current concerns involve our large series of 30 asymptomatic patients (31 hips) with a radiographically stable implant without osteolysis signs but with elevated blood metal ion concentrations.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 309 - 309
1 Mar 2013
Randelli F Banci L Visentin O D'Anna A Randelli G
Full Access

Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear.

The aim of the present study was to evaluate the long-term results of a series of Metasul (Zimmer GmbH, Winterthur, Switzerland) metal-on-metal total hip arthroplasty (THA). Between January 1993 and September 1996, 149 cementless THAs with a 28 mm Metasul articulation were performed in 111 consecutive patients. Implant survivorship was calculated and clinical and radiographic evaluations were performed on 82 hips still available for follow-up at a mean of 18 years postoperatively.

Nine hips (6.0%) were revised. The cumulative probability of survival of the overall implant at 18 years postoperatively with revision for any reason as the end point, was 0.937 (95% confidence interval, 0.888 to 0.985). The cumulative probability of survival of Metasul with revision for any reason as the end point, was 0.956 (95% confidence interval, 0.916 to 0.997). Various degrees of radiolucencies and osteolysis were found proximally around the femoral components of 25 hips (20%).

Cementless Metasul THA showed high survival at 18 years postoperatively.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 107 - 108
1 Mar 2010
Randelli F D’Anna A Randelli P Visentin O Arrigoni P Randelli G
Full Access

Dislocation is the most relevant early complication after primary total hip replacement (THR) in literature. Many factors have been advocated for dislocation, either surgeon-related either patient-related. Component positioning seems to be of major importance in determining dislocation. We evaluated 152 randomised THR with a CT study between 985 THR done at our Institute since november 2004 to november 2006.

152 randomised primary THR on a total of 985. The same prosthetic pattern (head size, stem, cup). Lateral approach with total capsulectomy and external rotator tendon resection. All 152 patients underwent a post operative standardized CT study assessing cup antiverion and inclination angles and stem antiversion angle. Dislocated patients where furthermore analysed for any detail concerning their procedure and follow-up. A safe zone was then deduced for safer positioning.

During the follow-up period dislocation occurred in 5 hips (only one in the randomised group) assessing our rate of dislocation at 0.5%. All dislocation were managed with closed reduction and an articulated hip brace. No open reduction or revision surgery were further needed. The mean cup abduction was 47° in the dislocated hips and 49° in the control group. Mean cup anteversion was 29° in both groups. The mean stem anteversion was 8.2° in the dislocated group and 3.1° in the control group. No statistical difference could be reached between dislocation and cup positioning. A correlation between hip dyspalsia (Crowe II) as primitive diagnosis and dislocation could be reached considering all the THR procedures.

In THR inappropriate cup and stem positioning is considered an important risk factor of postoperative dislocation. Accurate and reproducible measurement is mandatory for implant positioning evaluation. Conventional radiographs cannot provide accurate and reproducible measurement. CT can provide a precise measurement of prosthetic components. Several studies failed to demonstrate a correlation between component positioning and dislocation often because of small number of patients and many bias. We tried to reduce bias using the same prosthetic pattern and the same surgical approach. Notwithstanding we could not reach a statistical difference in term of prosthetic positioning between dislocated and control group. Perhaps the dislocated group was too small to have a statistical meaning. We could determine a Safe Zone of cup and stem positioning for our patients: cup anteversion between 24° and 33°, cup inclination between 42° and 50°, stem anteversion between −3° and 10°.

Dislocation is the main early complication after THR. Its etiology depends on many factors. Sometimes the cause can’t be identified. Orientation of prosthetic components may be responsable for dislocation but its truly correlation can be hard to be assessed. In this study we found no correlation between implant positioning and occurrence of dislocation, but we defined a tighter Safe Zone than previous reported, in which the risk of dislocation is nought. A correlation between hip dyspalsia (Crowe II) as primitive diagnosis and dislocation could be reached.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 94 - 95
1 Mar 2010
Randelli F Randelli P Visentin O Arrigoni P Randelli G
Full Access

Metal on Metal coupling in total hip replacement has been widely used since many years. After the rebirth of resurfacing a new trend to use very large diameter metal-metal coupling with standard stem prostheses has been started. New prostheses, old and new problems. We analyze first failures with new large diameter metal on metal coupling.

The analysis focused on seven early failures of large diameter metal-metal prostheses (two resurfacing and five cementless prosthesis with XL head) over the first series of 350 cases (100 resurfacing and 250 cementless) in the first year. Synovial fluid aspiration have been performed in all failed patients searching for metal ions and bacterial proliferation. Moreover, prosthetic component positioning was also studied as a possible primum movens of these failures. Some failed patients underwent epicutaneous patch test for skin reaction to metal.

One resurface prosthesis failed as a result of an vascular necrosis and conseguent fracture of the femoral neck and revealed a moderate increment in metal ion concentration in blood and synovial fluid obtained at time of revision.

One resurface prosthesis failed as a result of an infected metallosis with a huge intraabdominal mass and revealed a huge increment in metal ion concentration in blood, addominal and synovial fluid. This patient underwent a lumbotomy to evacuate the abdominal retroperitoenal mass before prosthesis removal for a two step procedure.

Out of the five failures of metal on metal cementless prosthesis with XL head four were the result of aseptic loosening and one was the result of a low grade infection discovered at coltures after revision surgery. Three showed clear metallosis caused by wrong positioning (more than 50° of cup inclination). All of these three presented an articular noise and elevated blood and sinovial fluid metal ion concentration. The fourth patient with aseptic loosening had a good component positioning but demonstrated an epicutanous allergic reaction to Cobalt. Also one of the three patients with metallosis resulted allergic to Cobalt. The blood and sinovial metal ion values were always elevated but particularly high in patients with cup inclination over 50°.

Large head metal on metal prostheses demonstrated a higher percentage of early failure in our experience. They are very sensible to positioning. Blood and sinovial metal ion determination helps to promptly diagnose a bad metal on metal prosthetic functioning. A more accurate analysis about the different metals available on the market and their resistance to edge wear should not be delayed any further.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 268 - 268
1 May 2009
Randelli P Arrigoni P Randelli F Tassi A Cabitza P
Full Access

Aims: Healing of the rotator cuff after surgical repair continues to be one of the most challenging areas of shoulder surgery. Autologous Platelet Derived Grow Factors (PDGF) have been shown to positively affect the tissue healing, but their effect have not been studied in relation to tendon healing. The purpose of this study is to evaluate if the use of PDGF in rotator cuff surgery could lead to a better and faster healing of the repair.

Materials e Methods: We treated two groups (A,B) of 14 shoulders in 14 patients (mean age 66 and 63.4) with a full thickness rotator cuff tear. The group A and B were treated with a full arthroscopic repair of the cuff. In the group A, at the end of the procedure, the PDGF have been injected at the level of the lesion, between the tendon and the bone and over the tendon repair without irrigation and after the removal of all the cannulas. The group B, repaired in the same fashion, without PDGF, has been used as control.

In the group A the patients had an accelerated postop. rehabilitation. The group B received a standard rehabilitation protocol. Each group has been evaluated prospectively with VAS, UCLA and Constant scores pre-op and during follow-up.

Results: Both group showed an increase of the scores, compared to the pre-op. value (tab.1).

The VAS score of group A (PDGF) was pre-op. 5.6 and at 1 year 1.4. The VAS score of group B (no PDGF) was pre-op. 5.2 and at 1 year 1.4. The UCLA score of group A was pre-op. 16 and at 1 year 33.8. The UCLA score of group B was pre-op. 16.7 and at 1 year 32.9. The Constant score of group A was pre-op. 53 and at 1 year 90.7. The Constant score of group B was pre-op. 54.2 and at 1 year 90.1.

The complete statistical analysis of the data showed no significant differences in the results of the two groups (p< 0,01), with every kind of scores, VAS, UCLA and Constant, at the final follow-up of 1 year.

Conclusions: Our data suggest that the use of PDGF, compared to a standard repair, does not affect the quality of the rotator cuff repair at 1 year. Moreover the study suggest that the use of PDGF allows an accelerated rehabilitation program with ten days of immobilization compared to four weeks as usually prescribed. Further studies should clarify the real effect of PDGF about the acceleration of the first phase of the cuff healing.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 430 - 430
1 Apr 2004
Randelli G Brianza G Randelli F Randelli P Visentin O
Full Access

Total Hip Replacement (THR) in proximal, posterior iliac dislocation of the hip often represents a problematic issue. Reviewing their selected cases (70 patients between 3700 THR from 1986 to 2001), authors focalized some key points for this demanding surgery. The most important steps are acetabular positioning, implant decisioning and surgical approach (exposure and release).

Acetabular cup positioning. The natural site (Paleoacetabulum), the ideal place to restore biomechanical and dynamic properties of the joint, many times gives few chances to achieve primary stability. So one site, at least the nearest possible to the natural site must be reached. A CT or MRI study is necessary to assess preoperative planning for cup positioning. We used two different cups, the Zweymuller and the Wagner cup, with good primary stability. A Conus stem (Wagner) or an Alloclassic stem (in less displastic femoral shape) was used.

We always performed this surgery as a one step procedure. No preventing traction or release surgery was performed. An anatomic and wide (medial and lateral) exposure of the joint must be performed. We used the Smith-Petersen approach modified by Wagner. A meticulous periarticular release of soft tissue was performed. In same cases a shortening femoral osteotomy was performed to allow refractory reduction. Possible complications are discussed. Good clinical outcomes at more than ten years are shown.