Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 17 - 17
4 Apr 2023
Queen R Arena S
Full Access

Arthritis is a common and debilitating disease and is associated with an increased fall risk. The purpose of this study was to examine the effect of impacted joint and limb on fall risk as measured by the margin of stability (MOS).

There were 110 participants, including healthy controls (HC; n=30), ankle arthritis (AA; n=30), knee arthritis (KA; n=20) and hip arthritis (HA; n=30) patients. All protocols were Institutional Review Board approved and all participants signed informed consent. Participants walked approximately 6 meters at a self-selected pace. MOS was calculated in the foot coordinate system in the anterior/posterior (AP) and medial/lateral (ML) directions at heel strike. A one-way ANOVA was used to examine group effects (HC, AA, KA, HA) on gait speed. A two-way repeated measures ANOVA was used to examine the effects of limb (Non-Surgical, Surgical) and group on AP and ML MOS.

HC had the fastest gait speed (1.40±0.24 m/s; p<0.001) when compared to AA (0.85±0.24 m/s), KA (0.94±0.22 m/s) and HA (1.05±0.22 m/s). HA participants had a greater gait speed compared to AA (p=0.004). AP MOS was greater in the surgical limb compared to the non-surgical limb for AA (p<0.001) and HA (p<0.001). AP MOS was smaller in HC compared to AA, KA, and HA, regardless of limb (p<0.030). AP MOS was similar between AA, KA, and HA for the non-surgical limb (p>0.194) and the surgical limb (p>0.096). ML MOS was greater in the surgical compared to non-surgical limb (p=0.003). ML MOS was smaller in KA participants compared to all other groups (p<0.001).

Our results demonstrate stability during gait varies between limbs in arthritis patients, with a more conservative pattern for the surgical limb and suggest KA may be at an increased risk of falls with a smaller ML MOS.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 70 - 70
1 Jul 2020
Queen R Schmitt D Campbell J
Full Access

Power production in the terminal stance phase is essential for propelling the body forward during walking and is generated primarily by ankle plantarflexion. Osteoarthritis (OA) of the ankle restricts joint range of motion and is expected to reduce power production at that ankle. This loss of power may be compensated for by unaffected joints on both the ipsilateral and contralateral limbs resulting in overloading of the asymptomatic joints. Total ankle arthroplasty (TAA) has been shown to reduce pain and has the potential to restore range of motion and therefore increase ankle joint power, which could reduce overloading of the unaffected joints and increase walking speed. The purpose of this study was to test the hypothesis that ankle OA causes a loss of power in the affected ankle, compensatory power changes in unaffected lower limb joints, and that TAA will increase ankle power in the repaired ankle and reduce compensatory changes in other joints.

One hundred and eighty-three patients (86 men, 97 women with average ages 64.1 and 62.4 years respectively) requiring surgical intervention for ankle OA were prospectively enrolled. Implant selection of either a fixed (INBONE or Salto Talaris) or mobile (STAR) bearing implant was based on surgeon preference. Three-dimensional kinematics and kinetics were collected prior to surgery and one year post-operatively during self-selected speed level walking using an eight-camera motion capture system and a series of force platforms. Subject walking speed and lower extremity joint power during the last third of stance at the ankle, knee, and hip were calculated bilaterally and compared before and after surgical intervention across the entire group and by implant type (fixed vs. mobile), and gender using a series of ANOVAs (JMP SAS, Cary, NC), with statistical significance defined as p < 0 .05.

There were no gender differences in age, walking speed, or joint power. All patients increased walking as a result of surgery (0.87 m/s±0.26 prior to surgery and 1.13 m/s±0.24 after surgery, p < 0 .001) and increased total limb power. Normalized to total power (which accounts for changes in speed and distribution of power production across joints), prior to surgery the affected ankle contributed 19%±10% of total power while the unaffected ankle contributed 42%±12% (P < 0 .001). After surgery, the affected ankle increased to 25%±9% of total power and the unaffected ankle decreased to 38%±9% of total (P < 0.001). Other joints showed no significant power changes following surgery. Fixed bearing implants provide greater surgical ankle power improvement (61% versus 29% increase, p < 0 .002). Much of that change was due to the fact that those that received fixed-bearing implants had significantly lower walking speed and power before surgery.

Ankle OA reduced ankle power production, which was partially compensated for by the unaffected ankle. TAA increases walking speed and power at the affected ankle while lowering power production on the unaffected side. The modifications in power production could lead to increased physical activity and reduced overloading of asymptomatic joints.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 90 - 90
1 Mar 2017
Wellman S Queen R
Full Access

Introduction

Mid-flexion stability after total knee arthroplasty (TKA) is dependent, in large part, on implant design. Design variables include retention or sacrifice of the posterior cruciate ligament, conformity of the polyethylene tibial surface, and radius of curvature of the femoral component. In this study, we attempted to isolate the impact of femoral component design by comparing a single-radius design (SR) to a J-Curve design (JC). We selected cruciate-retaining implants to eliminate the effect of a cam-and-post mechanism. Mid-flexion performance these two designs were compared using the Lower-Quarter Y-Balance Test (YBT-LQ), as well as patient reported outcomes and measures of physical performance. The YBT-LQ is a simple functional test of unilateral lower extremity strength and balance. Reach of the contralateral limb is measured in three different directions (Figures 1–3). Our hypothesis was that the SR design would provide superior mid-flexion stability, and therefore, a greater reach distance in the YBT-LQ when compared to the JC group.

Methods

Patients undergoing primary, unilateral TKA were prospectively enrolled and block randomized to receive either the SR (n=30) or JC (n=30) implant. All surgeries were performed by one surgeon using a gap-balancing technique with a cruciate-retaining implant design. Patients completed outcome measures (KOOS, KSS, UCLA Activity), performed the YBT-LQ, and completed physical performance measures (walking speed, timed up-and-go, sit-to-stand) before surgery and 1 year postoperatively. A series of 2×2 repeated measures ANOVAS (Implant group x Time) were completed.