Vol. 86-B, Issue SUPP_III | Pages 329 - 329
1 Mar 2004
Meda P Garg N Davies R Pilling D Bruce C
Full Access

Aims: This study shows the efþcacy of The Pavlik harness for the treatment of Development Dysplasia of hip (DDH) using ultrasonographic monitoring. Methods: Between 1995–2000 we treated 149 dysplastic hips in 117 babies. According to the Grafñs classiþcation 90 were dysplastic type IIB, IIC, IID hips; 59 were dislocated Type IIIA, IIIB and IV hips. Babies were regularly monitored using ultrasound unto 26 weeks and radiographs up to 5 years in dislocated hips for bony roof angle. Results: The average full time harness treatment was 12.2 (range 6–20) weeks, average follow up was 55 (range 30–90) months. The harness failed to reduce 14 hips (9.5% of total hips). Two cases continue to show a small femoral ossiþc nuclei at 30 months follow up. The hips showed no signiþcant difference in acetabular index from the normal values at follow up radiographs. Conclusions: We conclude that using this protocol, successful initial treatment of DDH with the Pavlik harness appears to restore normal development of the hip.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 270 - 270
1 Mar 2003
Meda P Garg N Davies R Pilling D Bruce C
Full Access

This study shows the efficacy of The Pavlik harness for the treatment of Development Dysplasia of Hip using ultrasonographic monitoring. Between March 1995 and February 2000 we treated 149 dysplastic hips in 117 babies. According to the Graf’s classification 90 were dysplastic type IIB, IIC,IID hips; 59 were dislocated Type IIIA, IIIB and IV hips.

Babies were regularly monitored using ultrasound until the age of 26 weeks and radiographs there after for bony roof angle. The Pavlik harness was abandoned if there was persistent dislocation of hip at the end of 3 weeks of treatment. The average full time harness treatment was 12.2 ( range 6–20 ) weeks. The average follow up was 55 ( range 30–90 ) months.

The harness failed to reduce 14 hips ( 9.5 % of total hips). These required arthrogram and closed or open reductions. Late presentation beyond 12 weeks and a higher grade on the Graf’s classification reduces the success rate of the pavlik harness treatment. Two cases continue to show a small femoral ossific nuclei at 30 months follow up. The hips treated successfully showed no significant difference in acetabular index from the normal values at follow up radiographs.

We conclude that using our protocol, successful initial treatment of Developmental Dysplasia of Hip with the Pavlik harness appears to restore normal development of the hip. We continue to monitor patients by regular radiological surveillance up to 3 years in dysplastic hips and 5 years in unstable and dislocated hips.