Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 2 - 2
23 Feb 2023
Roffe L Peterson R Smith G Penumarthy R Atkinson N Ross M Singelton L Bodian C Timoko-Barnes S
Full Access

Trauma and elective orthopaedic demands in New Zealand are increasing. In this study, prospective and retrospective data has been collected at Nelson Hospital and across New Zealand to identify the percentage of elective theatre time lost due to cancellation for acute patient care. Data has been collected from theatre management systems, hospital data systems and logged against secretarial case bookings, to calculate a percentage of elective theatre time lost to acute operating or insufficient bed capacity.

Data was collected over a five-month period at Nelson Hospital, with a total of 215 elective and 226 acute orthopaedic procedures completed. A total of 95 primary hip or knee arthroplasties were completed during this trial while 53 were cancelled. The total number of elective operative sessions (one session is the equivalent of a half day operating theatre time) lost to acute workload was 47.9. Thirty-three percent of allocated elective theatre time was cancelled - an equivalent of approximately one-full day elective operating per week.

Over a five-week period data was collected across all provincial hospitals in New Zealand, with an average of 18% of elective operating time per week lost due to acute workload. Elective cancellations were due to acute operating 40% of the time and bed shortages 60% of the time. The worst effected centre was Palmerston North which had an average of 33% of elective operating cancelled per week to accommodate acute surgery or due to bed shortages.

New Zealand's provincial orthopaedic surgeons are under immense pressure from acute operating that impedes provision of elective surgery. The New Zealand government definition of an ‘acute case’ does not reflect the nature of today's orthopaedic burden. Increasing and aging populations along with staff and infrastructure shortages have financial and societal impacts beyond medicine and require better definitions, further research, and funding from governance.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 38 - 38
10 Feb 2023
Batinica B Bolam S Zhu M D'Arcy M Peterson R Young S Monk A Munro J
Full Access

Little information exists regarding optimal tibial stem usage in revision total knee arthroplasty (rTKA) utilising a tibial trabecular metal (TM) cone. The purpose of this study was to compare 1) functional outcomes, 2) radiographic outcomes, and 3) implant survivorship in rTKA utilising TM cones combined with either short stems (SS) or long stems (LS) at minimum two-years clinical follow-up.

In this retrospective, multi-centre study, patients undergoing TM cone utilising rTKA between 2008 and 2019 were included. Patients were divided into: SS group (no diaphyseal engagement), and LS group (diaphyseal engagement). All relevant clinical charts and post-operative radiographs were examined. Oxford Knee Score (OKS) and EuroQol-5D (EQ-5D-5L) data were collected at most recent follow-up.

In total, 44 patients were included: 18 in the SS group and 26 in the LS group. The mean time of follow-up was 4.0 years. Failure free survival was 94.5% for the SS group and 92.3% for the LS group. All failures were for prosthetic joint infections managed with debridement, antibiotics, and implant retention. At most recent follow-up, 3 patients demonstrated radiographic signs of lucency (1 SS 2 LS, p = 1) and the mean OKS were 37 ± 4 and 36 ± 6 (p = 0.73) in the SS and LS groups, respectively.

Tibial SS combined with TM cones performed as well as LS in rTKA at minimum two-years follow-up. A tibial SS in combination with a TM cone is a reliable technique to achieve stable and durable fixation in rTKA.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 320 - 320
1 May 2006
Peterson R Horne G Devane P Adams K Purdie G
Full Access

To assess if highly cross-linked polyethylene is associated with less linear wear than ultra high molecular weight polyethylene in vivo.

To assess whether alteration in biomechanical characteristics of the reconstructed hip influence’s wear patterns.

A randomised prospective trial comparing conventional polyethylene with highly cross-linked polyethylene in an acetabular component was designed. Identical cemented stems were used in all cases, with a metal head. The polyethylene thickness was controlled. The trial design required 124 cases to be entered to give the study sufficient power to determine any difference in wear rates. Polyware Auto was used to assess 2D wear rate and volume.

This paper presents the preliminary results of the early patients entered into the study and looks at both 2D wear or creep at 18 months post operatively, and seeks to establish any relationships between 2D movement and biomechanical characteristics of the reconstructed hip.

There was no significant difference in the 2D wear (or creep) between the two types of polyethylene at 18 months. There was no correlation between femoral offset, cup offset, or centre of rotation offset and 2D wear (or creep).

This preliminary data shows no difference in the early wear rate of the two types of polyethylene. This is in contrast to an in vitro wear simulator study that has shown more creep in highly cross-linked polyethylene. The significance of this observation is unclear. We hope to demonstrate that as the trial progresses any difference in the performance of the two types of polyethylene should be evident.