Focal knee arthroplasty is an attractive alternative to knee arthroplasty for young patients because it allows preservation of a large amount of bone for potential revisions. However, the mechanical behaviour of cartilage has not yet been investigated because it is challenging to evaluate in vivo contact areas, pressure, and deformations from metal implants. Therefore, this study aimed to determine the contact pressure in the tibiofemoral joint with a focal knee arthroplasty using a finite element model. The mechanical behaviour of the cartilage surrounding a metal implant was evaluated using finite element analysis. We modelled focal knee arthroplasty with placement flush, 0.5 mm deep, or protruding 0.5 mm with regard to the level of the surrounding cartilage. We compared contact stress and pressure for bone, implant, and cartilage under static loading conditions.Aims
Methods
Surgical debridement for medial epicondylitis (ME) is indicated for patients with refractory ME. The clinical efficacy of simple debridement has not been studied sufficiently. Moreover, authors experienced surgical outcome of ME was not as good as lateral epicondylitis. In this regard, authors have combined the atelocollagen injection in the debridement surgery of ME. The purpose of study was to compare clinical outcomes between simple debridement and debridement combined with atelocollagen injection in the ME. Twenty-five patients with refractory ME and underwent surgical debridement were included in the study. Group A (n=13) was treated with isolated debridement surgery, and group B (n=12) was treated with debridement combined with 1.0 mL of type I atelocollagen. Pain and functional improvements were assessed using visual analogue scale, Mayo Elbow Performance Score (MEPS) and quick Disabilities of the Arm, Shoulder and Hand (DASH) scale respectively before surgery, at 3, 6 months after surgery and at the final follow-up. Demographic data did not show significant difference between two groups before surgical procedures. Both groups showed improvement in pain and functional score postoperatively. However, at the 3 months after surgery, group B showed significantly better improvement as compared to group A(VAS 3.1 / 2.0, MEPS 71/82 qDASH 29/23). At the 6 months after surgery and final follow-up, both groups did not show any difference. Surgical debridement combined with atelocollagen is effective treatment option in refractory ME and showed better short-term outcomes compared to isolated surgery.
Olecranon plates used for the internal fixation of complex olecranon fractures are applied directly over the triceps tendon on the posterior aspect of the olecranon. The aim of the study is to describe the relationship of the plates and screws to the triceps tendon at the level of the olecranon. Eight cadaveric elbows were used. Dimensions of the triceps tendon at the insertion and 1cm proximal were measured. A long or a short olecranon plate was then applied over the olecranon and the most proximal screw applied. The length of the plate impinging on the tendon and the level of the screw tract on the tendon and bone were measured. The mean olecranon height was 24.3cm (22.4-26.9cm) with a tip-to-tendon distance of 14.5cm (11.9-16.2cm). The triceps tendon footprint averaged 13.3cm (11.7-14.9cm) and 8.8cm (7.6-10.2cm) in width and length, respectively. The mean width of the central tendon 1 cm proximal to the footprint was 6.8 cm. The long olecranon plate overlay over more movable tendon length than did the short plate and consequently the superior screw pierced the triceps tendon more proximally with the long plate. Using the Mann-Whitney U test, the differences were significant. The long olecranon plates encroach on more triceps tendon than short plates. This may be an important consideration for olecranon fractures with regards implant loosening or triceps tendon injury.
To test the hypothesis that reseeded anterior cruciate ligament (ACL)-derived cells have a better ability to survive and integrate into tendon extracellular matrix (ECM) and accelerate the ligamentization process, compared to adipose-derived mesenchymal stem cells (ADMSCs). Acellularized tibialis allograft tendons were used. Tendons were randomly reseeded with ACL-derived cells or ADMSCs. ACL-derived cells were harvested and isolated from remnants of ruptured ACLs during reconstruction surgery and cultured at passage three. Cell suspensions (200 µl) containing 2 × 106 ACL-derived cells or ADMSCs were prepared for the purpose of reseeding. At days 1, 3, and 7 post-reseeding, graft composites were assessed for repopulation with histological and immunohistochemical analysis. Matrix protein contents and gene expression levels were analyzed.Aims
Methods
There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition.Aims
Methods
Joint arthroplasties may be associated with a blood loss, which necessitates transfusion. Especially, hip arthroplasties are highly associate with transfusion to compensate perioperative bleeding. Orthopaedic surgeons and patients have increasing concerns regarding complications of blood transfusions. Although various methods to reduce transfusions have been attempted in TJA, a high percentage of patients require a transfusion during and after the procedures. The purposes of this study were to evaluate the trends of the transfusion(transfusion rates, transfusion amounts, economic burden) in hip arthroplasties, using nationwide data from the National Health Insurance Service (NHIS). We used data from nationwide claims database of Health Insurance Review Assessment Service (HIRA). The data managed by the NHIS were used to identify the 161,934 hip arthroplasties by 3 categories including bipolar hemiarthroplasty(BH), total hip arthroplasty(THA), and revision arthroplasty(RA) from 2007 to 2015. These 3 categories were classified using the operation code recorded in the requisition data of NHIS. The transfusion rates, transfusion amounts, proportion of transfusion, cost of each type of operation was investigated and stratified by age, gender, hospital type, and area in hip arthroplasties. The proportion of transfusion about whole blood, red blood cell, fresh frozen plasma, platelet, was also evaluated in hip arthroplasties.Aims
Patients and methods
Previous hemodynamics studies in shoulder arthroplasty only evaluated Western population and mainly focused on risk factors of transfusion. However, Asians are relatively small, and have higher bleeding risk due to prothrombin-clotting-factor polymorphisms. Therefore, it is not appropriate to apply the results of previously studies directly to Asians. Authors compare different hemodynamics depending on the types of shoulder arthroplasties, and evaluate predictors for transfusion in Asian population. Total 212 shoulder arthroplasties (26 fracture hemiarthroplasty (fHA), 49 anatomical total shoulder arthroplasty (aTSA), 132 reverse total shoulder arthroplasty (rTSA), and 5 revision surgery) from August 2004 to January 2016 were retrospectively reviewed. Demographics, surgical factors and perioperative hemodynamic factors were compared for each type of arthroplasty. Multivariate regression analysis was conducted to determine predictors for transfusion.Introduction
Methods
A stem sitting proud (SP) or that above the final rasp position remains in some patients who undergo hip replacement using proximally coated tapered wedge stems. Surgeons may face challenges providing the best fit due to unpredictable stem seating. Zimmer Inc. introduced a new rasp to solve this issue but the clinical results of this rasp have not yet been published. Therefore, we aimed to address the following: 1) What is SP incidence using a proximally coated cementless tapered wedge stem? 2) Does the new rasp system improve seating height? 3) What are the risk factors of SP? We performed a retrospective study with 338 hips, in which Tri-Lock Bone Preservation Stem (BPS) was used in 181 and M/L Taper stem was used in 157 hips (82 hips before and 75 hips after the new rasp). A positive stem SP was defined as a stem proud height of >2 mm. We analyzed and compared SP incidence in two stems and in M/L Taper stems before and after the new rasp use.Background
Methods
Clinical outcome after reverse total shoulder arthroplasty (RTSA) can be influenced by technical and implant-related factors, so the purpose of this study was to investigate whether individualizing humeral retroversion and subscapularis repair affect the clinical outcomes after RTSA. Authors retrospectively analyzed the prospectively collected data from 80 patients who underwent RTSA from January 2007 to January 2015 using same implant (Biomet Comprehensive® Reverse Shoulder System, Warsaw, Indiana). The mean follow up was 23.3 ± 1.7 (range, 12 ∼ 70) months. The retroversion of humeral component was decided according to native version estimated using shoulder CT in Group I (n=52), and fixed in 20° retroversion in Group II (n=28). Group I was subdivided into Group Ia (n=21, mean 19.3°), less than 20° of retroversion, and Group Ib (n=31, mean 31.9°), more than 20°. Intraoperative tenotomized subscapularis was repaired in 40 patients in Group I, and could not be repaired due to massive tear including subscapularis in remaining 12 patients. Clinical outcomes were evaluated with range of motion (ROM) and several clinical outcome scores.Introduction & Background
Material & Method
Acetabular dysplasia cause hip joint osteoarthritis(OA) by change hip mechanism. However, to our best knowledge, no studies have been published using prospectively collected data from asymptomatic young age volunteers, precise radiographic method. The purpose of this study is to evaluate the prevalence of hip dysplasia in asymptomatic Korean population as one of the most important risk factor of hip OA. From December 2014 to March 2015, we investigated prospectively collected retrospectively reviewed data of 200 asymptomatic volunteers 400 hips in age between 18 and 50 years recruited from our institution. Pelvic radiographs were taken and all radiographs were reviewed by 2 experienced orthopedic surgeons. Lateral center-edge angle(LCEA), Sharp angle, Tonnis angle and acetabular width-depth ratio were measured. We analyzed the statistical differences of these values between sex by Mann-Whitney U test and independent t-test. Pearson's correlation coefficient was used to measure the relationship between dysplasia parameters.Introduction
Materials & Methods
We report a case of fatal heart failure caused by cobalt intoxication after revision THR in the patient who successfully underwent re-revision THR. 53-year old male presented to emergency room in our hospital with progressive shortness of breath. Symptom was started about 6 months ago so he visited local hospital. He worked up for worsening dyspnea. Simple chest radiograph and enhanced heart MRI study were performed and they showed bilateral pericardial and pleural effusion. There was no evidence of ischemic change. Transthoracic echocardiogram showed the evidence of heart failure, left ventricular ejection fraction(EF) was 40%. He was admitted at local hospital and started on vasopressors but urine output was decreased and follow-up echocardiogram showed a 25% of EF. Patient recommended heart transplantation and transferred our hospital emergency room. He underwent sequential bilateral total hip arthroplasties using CoP bearing surfaces. At 12 years postoperatively, he presented to the other hospital with acute onset of left hip pain. He was diagnosed ceramic head fracture on his left hip. Head and liner change revision surgery was performed using Cobalt-Chrome alloy 28mm metal head and Protruded cross-linked polyethylene liners. In our hospital, the patient admitted cardiovascular department of internal medicine. Patient complained nonspecific fatigue and general weakness but had no other symptoms such as visual and hearing loss, cognitive dysfuction. During work-up, patient presented progressive left hip pain and complaint of discomfort for the mass on the left groin. He also complained Left leg weakness and numbness. Simple radiograph and enhanced CT study was done. Simple radiograph image shows radiodense area around the hip joint and radiologist suspected heterotopic ossification. The cardiovascular department consulted orthopedic department. In the image findings showed huge mass combined hemorrhagic component lining acetabular component extending psoas compartment and eccentric wear on cobalt-chrome alloy metal head. Also highly radiodense material was seen around neck inferor portion and severly deformed metal head was seen. It was highly suspected that metal related granuloma, which means severe metallosis. Performed heavy metals screen, cobalt levels were 397,800
We compared visible blood loss and calculated blood loss after bipolar hemiarthroplasty in femoral neck fracture, and evaluated correlation between blood loss and its risk factors. Materials and Methods: A total of 356 patients who underwent bipolar hemiarthroplasty in femoral neck fracture between 2004 and 2010 were enrolled in this study. The total blood loss was calculated using the formula reported by Mercuiali and Brecher. We analyzed several factors, including gender, age, body mass index (BMI), anesthesia method, cardiovascular and cerebrovascular disease, preoperative anemia, American Society of Anesthesiologists (ASA) score, use of cement, and use of antithrombotic agents. Results: Total calculated blood loss (1,408±72 ml) differed significantly from visible blood loss(980±102 ml). In addition, calculated blood loss differed between risk factors (1,526±369 ml in cardiovascular disease, 1,588±279 ml in general anesthesia, 1,645±920 ml in obesity, and 1,605±439 ml in use of antithrombotic agents). Conclusion: Total calculated blood loss was much greater than visible blood loss. Patients with risk factors such as cardiovascular disease, obesity, use of antithrombotic agents, and general anesthesia should be treated with care in order to reduce blood loss.Purpose
Venous thromboembolism (VTE), including pulmonary embolism (PE) resulting from deep vein thrombosis (DVT), remains a well-known serious complication after femoral fractures. The low molecular heparin is widely used to prevent VTE. This study compared the effectiveness of VTE prevention between dalteparin and enoxaparin. From 2013 to 2014, we retrospectively recruited 712 patients who had femoral fractures with operative treatment. All patients receiving VTE chemoprophylaxis with perioperative period using dalateparin in Group 1(N=395) and enoxaparin in Group 2(N=317). The prophylactic dosing was determined using individual product labeling and identified as enoxaparin 40 mg every 12 hours and dalteparin 2500 international unit (IU) once daily, based on clinical practice guidelines. The prophylaxis was started at admission, and maintained during average 8.43.5 days after operation. The outcome including the incidence of clinically significant deep vein thrombosis, pulmonary embolism, perioperative bleeding and cost of drugs were evaluated between two groups.Introduction
Materials and Methods
Arthroplasties of hip and knee are associated with blood loss, which may lead to adverse patient outcome. Jehovah's Witnesses do not accept blood transfusion. Performing arthroplasties in Witness patients without transfusion has been a matter of concern. We developed a protocol, which avoids transfusion in arthroplasties of Witness patients, and evaluated the feasibility and safety of the protocol. Our protocol consisted of subcutaneous administration of 4000 U recombinant erythropoietin and 100 mg of intravenous iron supplements when patient's hemoglobin level was less than 10 g/dL in preoperative evaluation. During the operation, cell saver, and plasma expander were used. Postoperatively, recombinant erythropoietin was administered three times a week and iron supplements were administered daily until the hemoglobin level reached 10 g/dL. We evaluated the feasibility of our protocol, perioperative complications and hematologic changes.Introduction
Materials and Methods
The purpose of this study is to report the outcome of navigation-assisted cruciate-retaining total knee arthroplasty (TKA) using one type of cemented, second-generation, floating-platform (FP), mobile-bearing system. We retrospectively reviewed 42 patients (51 knees) who underwent cruciate retaining TKAs using e.motion-FP prostheses under navigational guidance. The preoperative diagnosis was osteoarthritis in all knees except one rheumatoid arthritis. There were 2 men (2 knees) and 40 women (49 knees) with a mean age of 64.0 ± 4.7 years (range, 51 – 76 years) at the time of index surgery. The mean follow-up was 120.0 months (range, 106 – 126 months). Clinical and radiographic results as well as mechanical survival rate of this type prosthesis were investigated at a mean follow-up of 10 years.Background
Methods
We sought to determine the 10-year survivorship of single-radius, posterior-stabilized total knee arthroplasty (TKA) in Asian patients. We also aimed to determine whether the long-term clinical and radiographic results differed between patients with and without patellar resurfacing. This retrospective study included 148 (115 patients) consecutive single-radius, posterior-stabilized TKAs. Ten-year survivorship analysis was performed using the Kaplan-Meier method with additional surgery for any reason as the end-point. Furthermore, long-term clinical and radiographic results of 109 knees (74%; 84 patients) with more than a 10-year follow-up were analyzed. Ten-year survivorship and long-term outcomes after surgery were determined, and outcomes were compared between patients with and without patellar resurfacing.Introduction
Materials and Methods
In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty(BH), compression hip screw(CHS) and proximal femur nail antirotatory(PFNA) in treating comminuted intertrochanteric fractures(AO type, A2(21, 22, 23)) We retrospectively evaluated total 150 patients(BH:50, CHS:50, PFNA: 50) who were operated due to intertrochanteric fractures from March 2010 to Dec 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris hip score, ability of ambulation(Koval stage), visual analogue scale and radiologic limb length discrepancy(shortening). Landmark and radiologic length was checked.
–A: postoperative length –A’: POD 1year –B: immediate posteopative contralateral length(from hip center to distal tip of lesser trochanter) –B’: POD 1year contralateral length(from hip center to distal tip of lesser trochanter) –
Limb length(shortening) was adjusted considering difference of magnification = {A × (B’/B)}− A’Introduction
Materials and Methods
The success of total knee arthroplasty depends on many factors, including the preoperative condition of the patient, the design and materials of the components and surgical techniques. It is important to position the femoral and tibial components accurately and to balance the soft tissues. Malpositioning of the component can lead to failures due to aseptic loosening, instability, polyethylene wear and dislocation of the patella. In order to improve post-operative alignment, computer-aid systems have been developed for total knee arthroplasty. Many clinical and experimental studies of these systems have shown that the accuracy of implanted components can be improved in spite of the increase in costs and operating time. This may not, however, improve the outcome in the short-term. Restoration of the normal mechanical axis of the knee and balancing of the surrounding soft tissues have been shown to have an important bearing on the final outcome of knee replacement operations. In severely deformed knees, whether varus or valgus, these goals may be difficult to achieve. We compared the radiologic results of the mechanical axis and implant position of Total Knee Arthroplasty using a robot-assisted method with conventional manually implanted method in severe varus deformed knee. A data set of 50 consecutive cases that were performed from April 2007 to December 2010 using the robot assisted TKA(Group A) were compared with a data set of 50 consecutive cases from the same period that were done using conventional manual TKA(Group B). All cases had a preoperative mechanical varus deformity >15° and one brand of implant was used on all cases. The diagnosis was primary osteoarthritis in all knees. The operations were performed by one-senior author with the same robot system, ROBODOC (ISS Inc., CA, USA) along with the ORTHODOC (ISS Inc., CA, USA) planning computer. (See Figure 1.) The radiological evaluations included mechanical axis, implant position (α,β,γ,δ angle) according to the system of American Knee Society.Introduction
Materials and Methods
Since Smith-Peterson's glass mold arthroplasty in 1939, hip resurfacing arthroplasty was developed and introduced to orthopaedic surgery field but it had many problem like early loosening. Recently it is being popular for some indication as development of new implant design and manufacturing. There are still many suggested advantages of hip resurfacing arthroplasty. These include bone conservation, improved function as a consequence of retention of the femoral head and neck and more precise biomechanical restoration, decreased morbidity at the time of revision arthroplasty, reduced dislocation rates, normal femoral loading and reduced stress-shielding, simpler management of a degenerated hip with a deformity in the proximal femoral metaphysic, an improved outcome in the event of infection, and a reduced prevalence of thromboembolic phenomena as a consequence of not using instruments in the femur. But, there are limited or inconsistent data to support some of these claims regarding the benefits of hip resurfacing including the potential for a more natural feel because of the minimal disturbance of the proximal part of the femur resulting in a better and faster functional outcome. We evaluate the short term results of hip resurfacing arthroplasty using custom patient-specific tooling for prosthesis placement for better standardization. 40 cases, 36 patients(male:20, female:16) those of who were candidates of a Hip Resurfacing procedure, participated in the study. Mean follow up period was 2.5 years (8 months ∼3 years). A CT scan was performed on each patient and a 3D model was generated using the computer tomography dataset. From this model a bone-surface skin was extracted and this data set was used to create a personalized jig. Detailed analysis of the native bone structure was then used to preoperatively plan the appropriate size and position of the implant. A mean 7 degree corrective valgus angle was prescribed on all cases. Postoperative radiological datasets were superimposed onto preoperative plan position and offsets were measured. Operative times were recorded per step during the procedure. Surgeon comfort and ease of use was also noted.Introduction
Materials and Methods
No study compared the clinical results of the posterior-stabilized mobile-bearing knee with those of nonposterior-stabilized mobile-bearing knee in the same patients. The purpose of this study was to examine whether the clinical and radiographic results, range of motion, patients satisfaction, and complication rates would be better in the knees with a posterior-stabilized mobile-bearing knee than in the knees with a nonposterior-stabilized mobile-bearing knee. One hundred and fourteen patients (mean age, 67.9 years) received a nonposterior-stabilized mobile-bearing knee prosthesis in one knee and a posterior-stabilized mobile-bearing knee prosthesis in the contralateral knee. Seven patients were men, and 107 were women. At the time of each follow-up (mean, 7.3 years; range, seven to 7.6 years), the patients were assessed clinically and radiographically.Background
Methods