Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 46 - 46
1 May 2021
Pickles E Sourroullas P Palanivel A Muir R Moulder E Sharma H
Full Access

Introduction

Deformity influences the weight bearing stresses on the knee joint. Correction of mechanical alignment is performed to offload the knee and slow the rate of degenerative change. Fixator assisted deformity correction facilitates accurate correction prior to internal fixation. We present our results with standard Ilizarov and UNYCO system assisted deformity correction of the lower limb.

Materials and Methods

Retrospective analysis of adult surgical cases of mechanical re-alignment performed between 2010 and 2019 in a tertiary referral centre. We recorded standard demographics and operative time from the electronic patient record. We analysed digitalised radiographs to record pre- and post-operative measurements of: Mechanical axis deviation (MAD), femoral tibial angle (FTA), Medial Proximal tibial angle (MPTA) and Mechanical lateral distal femoral angle (mLDFA). The accuracy of the correction was analysed. Time to healing, secondary interventions and complications were also recorded.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 36 - 36
1 Dec 2018
Dhoshi K Kumar A Palanivel A
Full Access

Aim

To assess the effectiveness of role of frozen section in revision arthroplasty.

Method

21 patients with infected hip arthroplasties were operated in the form of one or two-staged revision hip arthroplasties. A frozen section was obtained intra-operatively and >5 PMN's/ HPF was considered as a positive indicator of infection. Fig 1 llustrating frozen section image. If the frozen section was reported negative (≤5 PMN's/HPF), the revision prosthesis was implanted after a thorough debridement and a wash. If the frozen section was reported as positive, after the debridement a non-articulating antibiotic loaded cement spacer was implanted for 8 weeks, supplemented with 3 weeks of intravenous antibiotics and 3 weeks of oral antibiotics. This was followed by an antibiotic free interval of 2 weeks. The patient was taken up for a revision surgery once the frozen section study was negative (≤5 PMN's/HPF). The patients were followed up for minimum of 1 year to a maximum of 2 years after the revision for any evidence of infection (assessed clinically and serologically, radiologically).