Vol. 105-B, Issue SUPP_12 | Pages 43 - 43
23 Jun 2023
Carender CN Taunton MJ Fruth KM Pagnano MW Abdel MP
Full Access

There is a paucity of mid-term data on modular dual-mobility (MDM) constructs versus large (≥40 mm) femoral heads (LFH) in revision total hip arthroplasties (THAs). The purpose of this study was to update our prior series at 10 years, with specific emphasis on survivorships free of re-revision for dislocation, any re-revision, and dislocation.

We identified 300 revision THAs performed at a single tertiary care academic institution from 2011 to 2014. Aseptic loosening of the acetabular component (n=65), dislocation (n=59), and reimplantation as part of a two-stage exchange protocol (n=57) were the most common reasons for index revision. Dual-mobility constructs were used in 124 cases, and LFH were used in 176 cases. Mean age was 66 years, mean BMI was 31 kg/m2, and 45% were female. Mean follow-up was 7 years.

The 10-year survivorship free of re-revision for dislocation was 97% in the MDM cohort and 91% in the LFH cohort with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 5.2; p=0.03). The 10-year survivorship free of any re-revision was 90% in the MDM cohort and 84% in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.5; p=0.04). The 10-year survivorship free of any dislocation was 92% in the MDM cohort and 87% in the LFH cohort. There was a trend towards an increased risk of any dislocation in the LFH cohort (HR 2.3; p=0.06).

In this head-to-head comparison, revision THAs using MDM constructs had a significantly lower risk of re-revision for dislocation compared to LFH at 10 years. In addition, there was a trend towards lower risk of any dislocation.

Level of Evidence: IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 74 - 74
23 Jun 2023
Wilson JM Maradit-Kremers H Abdel MP Berry DJ Mabry TM Pagnano MW Perry KI Sierra RJ Taunton MJ Trousdale RT Lewallen DG
Full Access

The last two decades have seen remarkable technological advances in total hip arthroplasty (THA) implant design. Porous ingrowth surfaces and highly crosslinked polyethylene (HXLPE) have been expected to dramatically improve implant survivorship. The purpose of the present study was to evaluate survival of contemporary cementless acetabular components following primary THA.

16,421 primary THAs performed for osteoarthritis between 2000 and 2019 were identified from our institutional total joint registry. Patients received one of 12 contemporary cementless acetabular designs with HXLPE liners. Components were grouped based on ingrowth surface into 4 categories: porous titanium (n=10,952, mean follow-up 5 years), porous tantalum (n=1223, mean follow-up 5 years), metal mesh (n=2680, mean follow-up 6.5 years), and hydroxyapatite (HA) coated (n=1566, mean follow-up 2.4 years). Kaplan-Meier analyses were performed to assess the survivorship free of acetabular revision. A historical series of 182 Harris-Galante-1 (HG-1) acetabular components was used as reference.

The 15-year survivorship free of acetabular revision was >97% for all 4 contemporary cohorts. Compared to historical control, porous titanium (HR 0.06, 95% CI 0.02–0.17, p<0.001), porous tantalum (HR 0.09, 95%CI 0.03–0.29, p<0.001), metal mesh (HR 0.11, 95%CI 0.04–0.31, p<0.001), and HA-coated (HR 0.14, 95%CI 0.04–0.48, p=0.002) ingrowth surfaces had significantly lower risk of any acetabular revision. There were 16 cases (0.1%) of acetabular aseptic loosening that occurred in 8 (0.07%) porous titanium, 5 (0.2%) metal mesh, and 3 (0.2%) HA-coated acetabular components. 7 of the 8 porous titanium aseptic loosening cases occurred in one known problematic design. There were no cases of aseptic loosening in the porous tantalum group.

Modern acetabular ingrowth surfaces and HXLPE liners have improved on historical results at the mid-term. Contemporary designs have extraordinarily high revision-free survivorship, and aseptic loosening is now a rare complication.

At mid-term follow-up, survivorship of contemporary uncemented acetabular components is excellent and aseptic loosening occurs in a very small minority of patients.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 921 - 925
9 Nov 2021
Limberg AK Wyles CC Taunton MJ Hanssen AD Pagnano MW Abdel MP

Aims

Varus-valgus constrained (VVC) devices are typically used in revision settings, often with stems to mitigate the risk of aseptic loosening. However, in at least one system, the VVC insert is compatible with the primary posterior-stabilized (PS) femoral component, which may be an option in complex primary situations. We sought to determine the implant survivorship, radiological and clinical outcomes, and complications when this VVC insert was coupled with a PS femur without stems in complex primary total knee arthroplasties (TKAs).

Methods

Through our institution’s total joint registry, we identified 113 primary TKAs (103 patients) performed between 2007 and 2017 in which a VVC insert was coupled with a standard cemented PS femur without stems. Mean age was 68 years (SD 10), mean BMI was 32 kg/m2 (SD 7), and 59 patients (50%) were male. Mean follow-up was four years (2 to 10).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 2 - 2
1 Oct 2020
Uvodich ME Dugdale EM Taunton MJ Pagnano MW Berry DJ Abdel MP
Full Access

Introduction

Diagnosing acute postoperative periprosthetic joint infections (PJIs) after primary total knee arthroplasties (TKAs) remains difficult. Published diagnostic thresholds for ESR, CRP, and synovial fluid analysis have not been replicated. We aimed to validate the optimal cutoffs for detecting acute postoperative PJIs in a large series of primary TKAs.

Methods

We retrospectively identified 27,066 primary TKAs performed between 2000–2019. Within 12 weeks, 171 knees (170 patients) had a synovial fluid aspiration. Patients were divided into two groups: evaluation <6 weeks or 6–12 weeks. The 2011 MSIS criteria for PJI diagnosed infection in 22 knees. Mann-Whitney U tests compared medians; ROC analyses determined optimal thresholds. Mean follow-up was 5 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 3 - 3
1 Oct 2020
Wellings EP Couch CG Taunton MJ Pagnano MW Berry DJ Abdel MP
Full Access

Introduction

Patients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of aseptic acetabular component loosening. However, several series have reported improved results with tantalum acetabular components. The purpose of this study was to assess implant survivorship, radiographic results, and clinical outcomes of contemporary, non-tantalum, porous acetabular components in the setting of prior pelvic radiation.

Methods

We retrospectively reviewed 33 patients (38 hips) with prior therapeutic pelvic radiation between 2006 and 2016 who underwent primary THA. The mean overall pelvic radiation dose was 6300 cGy with a mean latency period to THA of 5 years. The most common acetabular component was Pinnacle (Depuy-Synthes) in 76%, followed by Trident (Stryker) in 8%, Tritanium (Stryker) in 8%, Trilogy (Zimmer-Biomet) in 5%, and G7 (Zimmer-Biomet) in 3%. Eighty-seven percent of cups were fixed with screws, of which the mean number used was 3. The mean age at primary THA was 74 years, 76% were male, and the mean BMI was 30 kg/m2. Mean follow-up was 5 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 12 - 12
1 Oct 2020
Wooster BM Abdel MP Berry DJ Pagnano MW
Full Access

Introduction

Arthrofibrosis remains a persistent complication following total knee arthroplasty (TKA). Although manipulation under anesthesia (MUA) is an effective early treatment, the risks and value of this procedure beyond 3 months after TKA remain controversial. The purpose of this study was to examine the safety and efficacy of late MUAs for arthrofibrosis.

Methods

From our institutional total joint registry, 82 TKAs (77 patients) who underwent MUA >3 months after primary (83%) or revision (17%) TKA were identified. Mean time to MUA was 7 months: 66% performed between 4–6 months, 18% between 7–12 months, 16% beyond 12 months. MUAs were coupled with arthroscopic assistance in 26% (12% limited lysis of adhesions, 13% formal arthroscopic debridement). Mean age was 61 years, 59% females, and mean BMI was 33kg/m2. Mean follow-up was 5 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 8 - 8
1 Oct 2020
Wyles CC Maradit-Kremers H Rouzrokh P Barman P Larson DR Polley EC Lewallen DG Berry DJ Pagnano MW Taunton MJ Trousdale RT Sierra RJ
Full Access

Introduction

Instability remains a common complication following total hip arthroplasty (THA) and continues to account for the highest percentage of revisions in numerous registries. Many risk factors have been described, yet a patient-specific risk assessment tool remains elusive. The purpose of this study was to apply a machine learning algorithm to develop a patient-specific risk score capable of dynamic adjustment based on operative decisions.

Methods

22,086 THA performed between 1998–2018 were evaluated. 632 THA sustained a postoperative dislocation (2.9%). Patients were robustly characterized based on non-modifiable factors: demographics, THA indication, spinal disease, spine surgery, neurologic disease, connective tissue disease; and modifiable operative decisions: surgical approach, femoral head size, acetabular liner (standard/elevated/constrained/dual-mobility). Models were built with a binary outcome (event/no event) at 1-year and 5-year postoperatively. Inverse Probability Censoring Weighting accounted for censoring bias. An ensemble algorithm was created that included Generalized Linear Model, Generalized Additive Model, Lasso Penalized Regression, Kernel-Based Support Vector Machines, Random Forest and Optimized Gradient Boosting Machine. Convex combination of weights minimized the negative binomial log-likelihood loss function. Ten-fold cross-validation accounted for the rarity of dislocation events.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 39 - 39
1 Oct 2019
Chalmers BP Matrka AK Sems SA Abdel MP Sierra RJ Hanssen AD Pagnano MW Mabry TM Perry KI
Full Access

Introduction

While knee arthrodesis is a salvage option for recalcitrant total knee arthroplasty (TKA) periprosthetic joint infection (PJI) it is used relatively uncommonly and contemporary data are limited. We sought to determine the reliability, durability and safety of knee arthrodesis as the definitive treatment for complex, persistently infected TKA in a modern series of patients.

Methods

We retrospectively identified 41 knees treated from 2002–2016 with a deliberate, two-stage knee arthrodesis protocol (TKA resection, high-dose antibiotic spacer, targeted IV antibiotics and followed by subsequent knee arthrodesis) in patients with complex TKA PJI. Mean age was 64 years & mean BMI was 39 kg/m2. Mean follow-up was 4 years. The extensor mechanism was deficient in 66% of knees, and flap coverage was required in 34% of knees. The majority of patients were host grade B (56%) or C (29%), and extremity grade of 3 (71%). Twenty-nine percent had poly-microbial infections, and 49% had multi-drug resistant organisms. Fixation included intramedullary nail (61%), external fixator (24%), and dual plating (15%).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 67 - 67
1 Oct 2019
Statz JM Maly C Carlson SW Abdel MP Hanssen AD Pagnano MW Perry KI
Full Access

Background

Uncemented dual-tapered stems are a popular choice for primary total hip arthroplasty (THA). The purpose of this study was to examine long-term outcomes after primary THA utilizing a single dual-tapered stem.

Patients and Methods

Utilizing our total joint registry, we retrospectively identified 1215 THAs (1055 patients) performed with an uncemented dual-tapered stem from 1998 to 2009. Mean age was 55 years, 70% were male, and mean BMI was 30 kg/m2. Mean follow-up was 10 years. Analysis included implant survivorship, clinical outcomes, and radiographic results.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 29 - 29
1 Oct 2019
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP
Full Access

Introduction

Metaphyseal fixation during revision total knee arthroplasties (TKAs) is important, but potentially challenging with historical cone designs. Material and manufacturing innovations have improved the size and shape of cones available, and simplified requisite bone preparation. In a very large series, we assessed implant survivorship, radiographic results, and clinical outcomes of new porous 3-D printed titanium metaphyseal cones featuring a reamer-based system.

Methods

We reviewed 142 revision TKAs using 202 cones (134 tibial and 68 femoral) from 2015 to 2016. Sixty cases involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. Mean age was 66 years, with 54 % females. Mean BMI was 34 kg/m2. Patients had a mean of 2.4 prior surgeries and 48% had a history of periprosthetic infection. Mean follow-up was 2 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 26 - 26
1 Oct 2019
Taunton MJ Wyles CC Hart A Hevesi M Perry KI Abdel MP Pagnano MW
Full Access

Introduction

There is renewed interest in dislocation after surgical approach with popularization of the direct anterior approach. The purported advantage of both the lateral and direct anterior approaches is decreased risk of dislocation. The purpose of this study was to assess the risk of dislocation by approach following modern primary THA.

Methods

All primary THAs at a single academic institution from 2010 to 2017 were analyzed through our institutional total joint registry. There were 7023 THAs including 3754 posterior, 1732 lateral, and 1537 direct anterior. Risk of dislocation was assessed against the competing risks of revision surgery and death as well as by individual patient and surgical factors including surgical approach. Risk of revision surgery was considered as a secondary outcome. Step-wise selection was utilized to develop multivariable models. Clinical outcomes were documented with the Harris Hip Score (HHS). Mean age was 63 years, 51% were female, and mean body mass index (BMI) was 30 kg/m2. Minimum follow-up was 2 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 18 - 18
1 Oct 2018
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP
Full Access

Introduction

Modular dual-mobility constructs reduce the risk of dislocation after total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chrome (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the mid-term serum Co and Cr levels after modular dual-mobilities used in revision and complex primary THAs, and specifically included patients revised for ALTR.

Methods

Serum Co and Cr levels were measured prospectively in 22 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. Mean age 64 years with 50% female. The mean follow-up was 4 years. Indications for modular dual-mobility were: periprosthetic joint infection treated with 2-stage exchange and subsequent reimplantation (n=8), ALTR revision (n=7), complex primary THA (n=6), and periprosthetic femoral fracture (n=1). Mean preoperative Co and Cr in patients revised for an ALTR were 29.7 µg/L and 21.5 µg/L, respectively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 74 - 74
1 Oct 2018
Hines JT Petis SM Amundson AW Sierra RJ Pagnano MW Abdel MP
Full Access

Introduction

Tranexamic acid (TXA) has been shown to significantly reduce transfusion rates in primary total hip arthroplasties (THAs), but data is limited in the revision setting. The purpose of the current study was to compare the rate of blood transfusions and symptomatic venous thromboembolic events (VTEs) in a large cohort of revision THAs treated with or without IV TXA.

Methods

We performed a retrospective review of 3,264 revision THAs (2,645 patients) between 2005–2014, of which 1,142 patients received IV TXA (1g at incision and 1g at closure). The mean age was 65 years with 49% males in the revision group with TXA, and 67 years with 45% males in the revision group treated without TXA. Outcomes analyzed included rates of transfusion and VTE (within 90 days) between cases treated with TXA and cases not treated with TXA. These comparisons were performed for the overall cohort, as well as within the subset of aseptic cases and septic cases. In order to minimize potential bias between these two subgroups, the analyses were weighted with inverse probability of treatment weights based on a propensity score which included age at revision THA, sex, BMI, ASA score, preoperative anticoagulation, and year of surgery. Mean follow-up was 2 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 15 - 15
1 Oct 2018
Petis SM Brown TS Pagnano MW Sierra RJ Trousdale RT Taunton MJ
Full Access

Introduction

The influence of surgical approach for total hip arthroplasty (THA) on scar healing and scar perception is unknown. The purpose of this study was to evaluate patients’ perception of their scar following direct anterior (DA) or posterior approach (PA) for THA utilizing validated scar assessment scales.

Methods

Fifty DA and 58 PA THA patients underwent scar assessment using the Patient Observer Scar Assessment Scale (POSAS) and Stony Brook Scar Evaluation Scales (SBSES). Patients were included if they had at least 1-year follow-up, and had no previous surgery or intervention (i.e. radiation) around the assessed hip. The mean age was different between the cohorts (DA 67 vs PA 62 years, p=0.03). Other variables including gender, BMI, Charlson Comorbidity Index, steroid use, diabetes, and smoking were similar (p>0.05 for all comparisons). All patients had subcuticular running closure, secured with skin adhesive glue. Mean time from THA to scar assessment was 3.1 and 3.6 years for the DA and PA groups, respectively (p=0.18).