Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 38 - 38
1 Dec 2020
KIDO M IKOMA K SOTOZONO Y MAKI M OHASHI S TAKAHASHI K
Full Access

The purpose of this study was to compare the outcomes of arthroscopic unilateral surgery and simultaneous bilateral surgery for posterior ankle impingement syndrome (PAIS) in athletes and to evaluate the usefulness of simultaneous bilateral surgery.

A total 48 hindfeet of 41 athletes (14 hindfeet of 14 males, 34 hindfeet of 27 females) who underwent arthroscopic surgery for PAIS were studied. Japanese society for surgery of the foot (JSSF) score and visual analogue scale (VAS) were compared before and after surgery, using Wilcoxon signed-rank test. The operation time and the time to return to sports activity were compared in 10 hindfeet of 5 patients who underwent simultaneous bilateral surgery and 38 hindfeet of 36 patients who underwent unilateral surgery, using Wilcoxon rank sum test.

Classic ballet was the most common type of sport that caused PAIS (59%, 24/41 athletes). Soccer (10%, 4/41 athletes), baseball (10%, 4/41 athletes), badminton (5%, 2/41 athletes), volleyball (5%, 2/41 athletes), and athletics (5%, 2/41 athletes) followed. The JSSF score improved significantly from 72.7 preoperatively to 98.9 postoperatively in unilateral surgery, and significantly improved from 75.2 preoperatively to 99.0 postoperatively in simultaneous bilateral surgery. VAS significantly decreased from 64.7 preoperatively to 4.8 postoperatively in unilateral surgery, and significantly decreased from 72.7 preoperatively to 1.0 postoperatively in simultaneous bilateral surgery. The operating time was 53.7 minutes on average for unilateral surgery and 101.0 minutes for simultaneous bilateral surgery, significantly longer in bilateral simultaneous surgery. The mean time to return to sports activity was 4.8 weeks for unilateral surgery and 9.6 weeks for simultaneous bilateral surgery, significantly longer in simultaneous bilateral surgery.

Both unilateral and simultaneous bilateral surgeries for PAIS in athletes were useful. It should be noted that the operating time and the time to return to sports will be longer. However, considering the 2 times hospitalizations and 2 times surgeries, simultaneous bilateral surgery is one of the treatment options for PAIS.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 24 - 24
1 Jan 2016
Masuda K Iwasawa M Ogihara S Takamure H Ohashi S Mori T
Full Access

Objective

The aim of this study was to investigate the clinical results of treatment for patients with periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) in our department.

Patients and Methods

Between April 2004 and March 2014, 9 patients with rheumatoid arthritis (RA) and 6 patients with osteoarthritis (OA) were identified as PJI following TKA and treated in our hospital. We investigated retrospectively the data of each patient, including the clinical background and the peri-operative data as well as the outcome at final follow-up.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 58 - 58
1 Apr 2013
Tobita K Okazaki H Sato W Matsumoto T Bessho M Ohashi S Ohnishi I
Full Access

The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Many researchers have attempted to monitor stiffness either directly or indirectly for the purpose of assessing strength, as strength has been impossible to assess directly in clinical practice. The purpose of this study was thus to determine the relationship between bending stiffness and strength using mechanical testing at different times during the healing process. Unilateral, transverse, mid-tibial osteotomies with a 2-mm gap were performed in 28 rabbits. The osteotomy site was stabilized using a double-bar external fixator. The animals were divided into four groups (n=7/group/time point; 4, 6, 8 and 12 weeks). A series of images from micro-computed tomography of the gap was evaluated to detect the stage of fracture healing and a 4-point bending test was performed to measure stiffness and strength. Formation of cortex and medullary canal at the gap was seen in the 12-week group and would represent the remodeling stage. In addition, the relationship between stiffness and strength remained almost linear until at least 12 weeks. However, stiffness recovered much more rapidly than strength. Strength was not fully restored until the later stages of fracture healing. However, the current study demonstrated that stiffness could be monitored as a surrogate marker of strength until at least the remodeling stage.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 12 - 12
1 Apr 2013
Tobita K Okazaki H Sato W Matsumoto T Bessho M Ohashi S Ohnishi I
Full Access

The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Echo tracking (ET) can noninvasively measure the displacement of a certain point on the bone surface under a load. Echo tracking has been used to assess the bone deformation angle of the fracture healing site. Although this method can be used to evaluate bending stiffness, previous studies have not validated the accuracy of bending stiffness. The purpose of the present study is to ensure the accuracy of bending stiffness as measured by ET. A four-point bending test of the gap-healing model in rabbit tibiae was performed to measure bending stiffness. Echo tracking probes were used to measure stiffness, and the results were compared with results of stiffness measurements performed using laser displacement gauges. The relationship between the stiffness measured by these two devices was completely linear, indicating that the ET method could precisely measure bone stiffness.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 63 - 63
1 Sep 2012
Kaneko M Ohnishi I Bessho M Matsumoto T Ohashi S Tobita K Nakamura K
Full Access

Introduction

Spinal aBMD only explains 50–80% of vertebral strength, and the application of aBMD measurements in isolation cannot accurately identify individuals who are likely to eventually experience bone fracture, due to the low sensitivity of the test. For appropriate treatment intervention, a more sensitive test of bone strength is needed. Such a test should include not only bone mineral density, but also bone quality. Quantitative computed tomography-based finite element methods (QCT/FEM) may allow structural analyses taking these factors into consideration to accurately predict bone strength (PBS). To date, however, basic data have not been reported regarding the prediction of bone strength by QCT/FEM with reference to age in a normal population. The purpose of this study was thus to create a database on PBS in a normal population as a preliminary trial. With these data, parameters that affect PBS were also analyzed.

Methods

Participants in this study comprised individuals who participated in a health checkup program with CT at our hospital in 2009. Participants included 217 men and 120 women (age range, 40–89 years). Exclusion criteria were provided. Scan data of the second lumber vertebra (L2) were isolated and taken from overall CT data for each participant obtained with simultaneous scans of a calibration phantom containing hydroxyapatite rods. A FE model was constructed from the isolated data using Mechanical Finder software. For each of the FE models, A uniaxial compressive load with a uniform distribution and uniform load increment was applied. For each participant, height and weight were measured, BMI was calculated. Simple linear regression analysis was used to estimate correlations between age and PBS as analyzed by QCT/FEM. Changes in PBS with age were also evaluated by grouping participants into 5-year age brackets. One-way analysis of variance was used to compare average PBS for participants in each age range. Mean PBS in the 40–44 year age range was taken as the young adult mean (YAM). The ratio of mean PBS in each age group to YAM was calculated as a percentage. A multivariate statistical technique was used to determine how PBS was affected by age, height, weight, and BMI.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 101 - 102
1 May 2011
Tobita K Ohnishi I Matsumoto T Ohashi S Bessho M Kaneko M Matsuyama J Nakamura K
Full Access

Introduction: Low-intensity pulsed ultrasound stimulation (LIPUS) can enhance bone regeneration and callus healing during fracture repair. However, whether a certain phase of the healing process in fracture repair in particular is infiuenced by LIPUS treatment remains unclear. In this investigation, the effect of LIPUS on callus remodeling in a gap healing model was evaluated by bone morphometric analyses using 3-dimensional (3D) quantitative micro computed tomography (μCT) at the healing site, providing information on the temporal sequence of mineralized remodeling events that characterize the gap healing.

Materials and Methods: The rabbit osteotomy model with 2-mm gap for the right tibia was immobilized with four pins fixed to an external fixator with double side bars. LIPUS was continued for both the treatment group (n=7/group/time point) and the control group (n=7/group/time point), for 20 min, six times/week, for 4, 6, or 8 weeks. The control group also received a sham inactive transducer under exactly the same condition as the LIPUS group. After the harvested tibia was scanned by μCT, region of interest was set at the callus healing area. It defined as a center of the osteotomy gap with a width of 1 mm. Morphometric parameters used for evaluation were mineralized callus volume (BV, cm3) and volumetric bone mineral density of mineralized tissue comprising the callus (mBMD, mBMD = BMC/ BV, mgHA/cm3). The whole ROI was measured and was subdivided into three zones. The periosteal callus zone (External), the medullary callus zone (Endosteal) and the remaining zone was the cortical gap zone (Intercortical). For each zone, BV and mBMD were measured. Data of the μCT evaluations were analyzed using a one-way ANOVA test. Statistically significant difference was set at p < 0.05.

Results: In the LIPUS groups, BV for the Endosteal zone was significantly lower for the 8-week group than for the 4-week group. Comparing results at the same time point, the LIPUS group at 8 weeks was significantly higher than that of the control group in the Intercortical zone. As for mBMD, in the LIPUS group, the 8-week group was significantly higher than the 4-week group for Total, External, Internal, and Endosteal zones, respectively. Comparing results at the same time point, mBMD was significantly higher for the LIPUS group at 8 weeks than for the control group in both External and Intercortical zones.

Discussion: The most striking finding in our study was that LIPUS accelerated bone formation in the Intercortical zone and callus resorption in the Endosteal zone. This suggests that LIPUS could shorten the time required for remodeling. However, the results of this study do not clarify whether an early phase in callus formation in particular is infiuenced by LIPUS.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 100 - 100
1 May 2011
Tobita K Ohnishi I Matsumoto T Ohashi S Bessho M Kaneko M Matsuyama J Nakamura K
Full Access

Introduction: Low-intensity pulsed ultrasound stimulation (LIPUS) reportedly enhances restoration of strength at fracture healing sites. However, evaluation of strength by mechanical testing was limited to only one direction, with either bending or torsion. Quantitative micro computed tomography (μCT) scans allow us to calculate strength-related parameters such as cross-sectional moment (CSM) and cross-sectional moment of inertia (CSMI). Previous studies have performed 2-dimensional (2D) analyses, and 3-dimensional (3D) evaluations have not been described. The purpose of this study was thus to investigate the effects of LIPUS on osteotomy healing using 3D analyses of CSM and CSMI.

Materials and Methods: Bilateral, transverse, mid-tibial osteotomies with a 2-mm gap were performed in 42 rabbits. LIPUS was continued for both the treatment group (n=7/group/time point) and the control group (n=7/ group/time point), for 20 min, six times/week, for 4, 6, or 8 weeks. The control group also received a sham inactive transducer under the same condition as the LIPUS group. After the tibia was scanned by μCT, region of interest (ROI) was set at the center of the osteotomy gap with a width of 1 mm. Center of gravity for the ROI and the XYZ coordinate was calculated. An optional line (I) can be drawn in this coordinate. The angle of the Z axis (𝛉) was measured, and also the degree of angle of the X axis (φ) was measured. The 3D CSM [I (φ, 𝛉)] around this line was calculated using the following equation: I (φ, 𝛉) = ∫ r2dV (mm5), where r is the distance of a voxel to the center of gravity (mm) and dV is the area of a voxel (mm3). The axial CSM was defined as CSMx: I (0, 90), CSMy: I (90, 90), whereas the polar CSM was also defined as CSMp: I (any, 0). 3D CSMI weighted by density distribution was calculated using the following equation: I’ (φ, 𝛉) = ∫ r2dm = ∫ ρr2dV (mg.mm2), ρ is the measured volumetric callus mineral density. Likewise CSMIx, CSMIy and CSMIp were calculated. These data of the μCT evaluations were analyzed using a one-way ANOVA test (p< 0.05).

Results: When 3D CSMs at the same time point were compared, values for the LIPUS groups were significantly higher than those for control groups for CSMx at 6 weeks and CSMp at 8 weeks. As for comparison of 3D CSMIs at the same time point, values for the LIPUS groups were significantly higher than those of the control groups for CSMIx, CSMIy, and CSMIp at 6 and 8 weeks.

Discussion: Bone healing by 3D CSM and CSMI has not been described before. Our results demonstrate that these bone strength parameters improved with LIPUS during the early phases. However, whether the late phase of callus formation is infiuenced remains unclear.


Introduction: There is a clear need for the development of more sensitive risk assessment tools for clinical predictors of fractures. Bone densitometries are limited in the ability to account for complex geometry, architecture, and heterogeneity of bone. Quantitative computed tomography (QCT)-based finite element (FE) Methods: (QCT/FEM) are able to perform structural analyses taking these factors into consideration to accurately predict bone strength. However, no basic data have been available regarding predicted strength (PS) of the proximal femur by QCT/FEM with reference to age in a normal population. The purpose of this study was thus to create a database on PS in a normal population as a preliminary trial. With these data, parameters that affect PS were also analyzed.

Methods: Participants in this study comprised individuals who participated in a health checkup program with computed tomography (CT) at our hospital in 2008. Participants included 487 men and 237 women (age range, 40–87 years). Exclusion criteria were provided. Scan data of the proximal femur were isolated and taken from overall data from CT of each participant with simultaneous scans of a calibration phantom containing hydroxyapatite rods. A FE model was constructed from the isolated data using Mechanical Finder software. For each of the FE models, loading and boundary conditions as well as the definition of PS were exactly the same as described by Bessho et al. (Bone 2009). For each participant, height, weight, and abdominal circumference (AC) were measured. The analyses included linear regression analysis relating age and PS, one-way analysis of variance to compare average PS among the groups of participants who were divided into 5-year age brackets, and multiple regression analysis to determine how PS was affected by age, height, weight, and AC. Differences were considered significant for values of p< 0.05.

Result: The following results were obtained. First, average PS was lower in women than in men for all age ranges. Second, PS in men under stance configuration, and those in women under stance and fall configurations significantly decreased with age. Third, weight positively affected PS in both men and women.

Discussion: This was the first study to investigate changes in PS with age in a normal population. Whether PS by QCT/FEM correlates more closely with fracture risk for osteoporotic patients in comparison to other bone densitometries remains unclear, but the our results did not contradict any existing concept of risk factors for fragility fracture. More baseline data for PS in normal populations need to be accumulated by increasing the number of participants in studies like this.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 138 - 138
1 Mar 2009
Ohnishi I Matsumoto T Matsuyama J Bessho M Ohashi S Sato W Okazaki H Nakamura K
Full Access

Ring frames have the advantage of allowing progressive correction. However, the available frames for complex deformities are heavy and bulky leading to poor compliance by patients. Also, the mounting procedure requires considerable expertise and skill. On the other hand, a unilateral external fixator has the advantages of less bulk and a lighter weight. Thus, it causes less disability and can achieve better patient compliance even with bilateral application. However, previous unilateral fixators have had various limitations with respect to deformity correction, such as restricted placement of hinges, restricted correction planes, and a limited range of correction angles. In addition, it was impossible to achieve progressive correction while fixation was maintained. To overcome these disadvantages of existing unilateral fixators, we developed a new fixator for gradual correction of multi-plane deformities including translational and rotation deformities. This unilateral external fixator is equipped with a universal bar link system. The link is constructed from three dials and two splines that are connecting the dials. The pin clamps are able to vary the direction of a pin cluster in the three dimensional planes. The system allows us to correct angulation, translation, rotation, and the combination of the above. In addition, open or closed hinge technique is available because the correction hinge can be placed right on the center of rotational angulation (CORA), or at any desired location, by adjusting the length of the link spline. By increasing the spline length, the virtual hinge can also be set far from the fixator. Gradual correction can be performed by rotating the three dials using a worm gear goniometer that is temporarily attached. A 3D reconstructed image of the bone is generated preoperatively. Preoperative planning can be done using this image. Mounting parameters are determined by postoperative AP and lateral computed radiography images. These postoperative images are matched with the pre-operative 3D CT image by 2D and 3D image registration. Then, the fixator can be virtually fixed to the bone. By performing virtual correction, it is possible to plan the correction procedure. The fixator is manipulated by rotating each of the three dials to the predetermined angles calculated by the software. Static load testing disclosed that the fixator could bear a load of 1700 N. No breakage or deformation of the fixator itself was recognized. Mechanical testing demonstrated that this new fixator has sufficient strength for full weight bearing, as well as sufficient fatigue resistance for repeated or prolonged use. The results of clinical application in patients with multi-plane femoral deformities were excellent, and correction with very small residual deformity was achieved in each plane.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 152 - 152
1 Mar 2009
Matsuyama J Ohnishi I Sakai R Miyasaka K Harada A Bessho M Ohashi S Matsumoto T Nakamura K
Full Access

The most important issue in the assessment of fracture healing is to acquire information on the restoration of mechanical integrity of the bone. To measure bending stiffness at the healing fracture site, we focused on the use of echo tracking (ET) that was a technique measuring minute displacement of bone surface by detecting a wave pattern in a radiofrequency echo signal with an accuracy of 2.6 μ. The purpose of this study was to assure that the ET system could quantitatively assess the progress, retardation or arrest of healing by detecting bending stiffness at the fracture site.

With the ET system, eight tibial fractures in 7 patients with an average age of 37 years (range: 24–69) were measured. Two tibiae in 2 patients were treated conservatively with a cast, and 6 tibiae in 5 patients were treated with internal fixation (intramedullary nailing: 4, plating: 1, screw 1). Patients assumed supine position, and the affected lower leg was held horizontally with the antero-medial aspect faced upwards. The fibula head and the lateral malleolus were supported and held tight by a Vacufix ®. A 7.5 Hz ultrasound probe was placed on each antero-medial aspect of the proximal and distal fragments along its long axis. Each probe was equipped with a multi-ET system with 5 tracking points with each span of 10 mm. A load of 25 N was applied at a rate of 5 N/second using a force gauge parallel to the direction of the probe and these probes detected the bending angle between the proximal and distal fragments. An ET angle was defined as the sum of the inclinations of both fragments. In the patients treated with a cast, the contralateral side was also measured and served as a control. Fracture healing was assessed time sequentially with an interval of 2 or 3 weeks during the treatment.

None of the patients complained of pain, or no other complication related to this measurement occurred. In the patient (patient:M) treated with a cast, the ET angle exponentially decreased as time elapsed (y = 1.4035e-0.1053x, R = 0.9754) and the radiographic appearance showed normal healing. Including this case, in all patients with radiographic normal healing, the ET angle exponentially decreased. However, in patients with retarded healing (patient:N), the decrease of the angle was extremely slow(y = 0.2769e-0.0096x, R = 0.815). In patients with non union (patient:T), the angle stayed at the same level.

With this method, noninvasive assessment of bending stiffness at the healing site was achieved. Bending angle measured by ET diminished over time exponentially in patients with normal healing. On the contrary, in patients with healing arrest, no significant decrease of the bending angle was recognized. It was demonstrated that the echo tracking method could be applicable clinically to evaluate fracture healing as a versatile, quantitative and noninvasive technique.