header advert
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 16 - 16
1 Aug 2013
Kumar S O'Neill G Stark A Jones B McCartney P Wells J Ingram R
Full Access

The aim of this study was to characterise noise associated with ceramic-on-ceramic total hip arthroplasty (THA).

A questionnaire was constructed to assess noise associated with THA. 116 patients responded. All had ceramic-on-ceramic hybrid THA at Glasgow Royal Infirmary between 2005 and 2007 using a Trident prosthesis and Exeter stem. Oxford Hip Questionnaires (OHS) were also completed by the patients.

16.4% of respondents reported noise associated with their ceramic hip. The vast majority reported onset at least 1 year after implantation. The most common noise types were ‘clicking’ (47%) or ‘grinding’ (42%), while ‘squeaking’ was least frequently reported (11%). Noise was most commonly brought on by bending and during sit to stand movements.

No correlation was identified between the incidence of noise and any patient specific factor or demographic variable. The mean OHS at questionnaire follow-up was 39 and there was no significant difference in OHS when comparing noisy and silent hips (p=0.65). Only 1 patient limited social or recreational activities and overall patients felt the noise had minimal effect on their quality of life.

Acetabular component inclination angles were compared on post-operative x-rays. There was no significant difference (p=0.51) in inclination angles of the noisy (47.1°±6.3°, range 30–57°) and silent hips (47.8°±6.1°, range 35–68°). The groups were further analysed for deviation out with the desirable inclination range of 40–45°. Of the noisy hips, a total of 73% were out with this range compared to 63% in the silent hip group.

The incidence of noise within this ceramic-on-ceramic THA group did not appear to be related to patient specific factors, patient reported outcome (OHS) or acetabular inclination angles. Subjective appraisal of the noise revealed that ‘squeaking’ was not common but patients tended to report ‘clicking’ and ‘grinding’ more. The precipitation of noise with bending activities reinforces a possible mechanical cause.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 32 - 32
1 Jun 2012
O'Neill G Smyth J Stark A Ingram R
Full Access

Exeter Trauma Stem (ETS) is one of the most common implants used for treating displaced intracapsular hip fractures in the UK. We previously performed a radiographic audit of these implants which showed good placement was difficult. This was in particular relation to leg length discrepancy (LLD). This study reviewed the clinical outcomes of these patients, in particular looking at the relation of leg length discrepancy to outcome.

We performed a clinical review of patients at 3 months and 1 year post ETS for hip fracture. Oxford hip score (OHS), Trendelenberg test, Visual Analogue Score (VAS) and walking aids required were recorded. Leg length discrepancy was determined radiographically on initial post op X-ray. This was recorded as Even (+/− 5mm), 6-10mm Long and >10mm long.

Seventy-two patients were reviewed at 3 months and 21 at 1 year. Mean VAS was 1.6. At 3 months 66% were Trendelenberg positive. Of those Trendelenberg positive at 3 months only 42% remained positive at 1 year. Mean OHS at 3months and 1 year was 30.8 and 32.1 respectively. On radiographic review 38 implants were Even, 24 were 6-10mm Long and 10 implants were >10mm Long. There was no correlation between leg length discrepancy and either VAS or Trendelenberg test. 45 patients ambulated independently pre-op. Of these only 8 ambulated independently post-op, 18 used a stick and 11 a Zimmer frame.

There was no correlation between post operative leg length discrepancy and either Visual Analogue Score, OHS or Trendelenberg test. Mean pain score was very low. There was however almost 10% of patients with a VAS greater than 6. 80% of patients dropped one ambulatory level post-op, this is consistent with previous studies. The ETS provides good pain relief with a low complication rate in the vast majority of patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 49 - 49
1 Jun 2012
O'Neill G Smyth J Stark A Ingram R
Full Access

The Trident acetabular system is the second most common cementless cup implanted in the UK. Recent studies have shown that malseating of the liner can be as high as 16.4%. We felt this was very high and were prompted to review our series and early clinical outcomes.

We reviewed 118 hips in 110 patients, implanted between from 2005-2007. We reviewed initial post operative X-rays using the technique described by Howcroft to identify malseating. The posterior approach was used in all cases. All cups were Trident PSL and all 85 Patients had OA, 10 RA, 8 AVN, 5 DDH, 3 OA post trauma, 2 Perthes, 2 Psoriatic Arthritis, 3 other. We only identified 3 malseated cups in 118 hips. 2 were in patients with OA secondary to trauma and 1 in primary OA. The rate of malseating for trainees operating was 5 % and only 1% when consultants were operating. There were no adverse events in these patients. No-one required revision. Oxford Hip Score (OHS) improved from 47 pre-op to 20 post op. This was compared to 47 and 22 in the correctly seated group (115 cases). Surprisingly the subgroup with the poorest OHS at 1 year had surgery for DDH, with a mean OHS of 31. The reasons for this are unclear.

Contrary to other studies our malseating rate is very low. We do not feel that malseating is a problem with Trident if adequate exposure is obtained. In those patients with sclerotic bone, we suggest over reaming the rim of the acetabulum by 1mm to avoid excess deformation of the shell which may lead to difficulty with seating the liner. We suggest trainees are supervised closely when using Trident.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 8 - 8
1 Apr 2012
O'Neill G Huntley JS
Full Access

Pelvic fractures in children are uncommon. Despite their potentially serious nature, there is little information in the literature regarding their epidemiology.

We performed a retrospective review of case notes and radiographs, if available, of all patients admitted with bony pelvic injuries to our unit over a 28 year period (1980-2008). Sixty-four children with pelvic fractures were identified (median age 8 years, 75% male). 58% were pedestrians involved in road traffic accidents (RTA), 19% were caused by a fall from a height and 8% were crush injuries. There was seasonal variability, with a 50% increase in pelvic injuries in Autumn and 33% decrease in Winter - compared to Spring/Summer months (in contrast to the peak in overall fracture incidence in the Summer). Median length of stay was 8 days (range 1-180), 11% requiring direct admission to ITU and 5% to HDU. There is a high incidence of associated major injuries - for Stable fractures 52%, Partially stable fractures 60% and Unstable fractures 100%. Five required surgery to the bony pelvis, and 6 for-non pelvic orthopaedic injury. 3 required operative intervention from other specialities, 1 urological repair, 1 laparotomy and 1 lobectomy.

Pelvic fractures in children are potentially serious injuries with a high proportion of major associated injuries. Multiple injuries were sustained in 55% of pedestrian/RTA accidents, 100% of crush injuries and 58% of falls from a height. In this series, 52% of “Stable” pelvic injuries were associated with other major injuries. All paediatric pelvic injuries, even stable pubic rami fractures should be approached with caution, full ATLS assessment and close monitoring.