header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 42 - 42
1 Jul 2020
Lotfi N Hughes E McCulloch R Horner C Shepherd D Grover L Nightingale P Davis E
Full Access

Polymethylmethacetate (PMMA) is a bone cement used in over 725,000 primary hip arthroplasties in 2018. Cement integrity is affected by external factors, including temperature, mixing technique and moisture uptake, which can influence cement microstructure. Changes in the cement microstructure may ultimately threaten the survivorship of the implant.

The introduction of enhanced recovery and various local anaesthetic infiltration techniques have been adopted in an attempt to facilitate early mobilisation and reduce length of stay. Our study aims to investigate if the mechanical properties of PMMA are altered with exposure to Ropivacaine LA.

Cements were cured in three separate states (air, serum and serum with LA) and the mechanical properties tested at 24 hours and 28 days. Using Refobacin bone cement provided by ZimmerBIOMET, cylindrical molds (12×6mm) were constructed with a split-mold. The LA used was 2mg/ml Ropivacaine hydrochloride solution. Using pilot data, this study was powered to 80% and a sample size of 10 per group (n=60) was calculated.

Cement samples were subjected to compressive loading using a universal testing apparatus (Zwick/Roell). Yield-strength and modulus values were extracted from the respective stress versus strain curves. Significant differences were determined by one-way anova for each time point, and Bonferroni post-hoc testing to determine significance between actual groups.

At 24-hours there were no significant differences in strength or modulus between groups. At 28-day strength and modulus increased in all groups. Compared to the air group, both serum and LA groups show a significant decrease in compressive strength. The modulus for the LA group is significantly less stiff compared to the air group.

The results suggest that the initial exposure to LA has a significant impact on the physical properties of the PMMA. We propose increased awareness of the potential effects this may have on the longevity and survivorship of cemented implants.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 178 - 178
1 Sep 2012
Heaver C Mart JS Nightingale P Sinha A Davis E
Full Access

Aims

Leg length inequality following total hip replacement remains common. In an effort to reduce this occurrence, surgeons undertake pre-operative templating and use various forms of intra-operative measurements, including computer navigation. This study aims to delineate which measurement technique is most appropriate for measuring leg length inequality from a pelvic radiograph.

Method

Three observers took a total of 9600 measurements from 100 pelvic radiographs. Four lines were constructed on each of the radiographs, bisecting the acetabular teardrops (Methods 1/2), ishial spines (Method 3/4), inferior sacroiliac joint (Method 5/6) and inferior obturator foramen (Method 7/8). Measurements were taken from these lines to the midpoint on the LT and to the tip of the GT.

The effect of pelvic positioning was also assessed using radiographs of a synthetic pelvis and femur using the same eight methods by a single observer (ED).

Intra-observer variability was analysed using within subject standard deviation. Inter-observer variability was analysed using the coefficient of inter-observer variability (CIV).