INTRODUCTION

Femur is one of the bones in humans that exhibit ethnic, racial, and gender difference. Several basic and clinical studies were conducted to explore these variations. Clinical anthropological studies have dealt with the compatibility of femoral prostheses and osteosythesis and materials with the femur. If there is a misalignment between the Total Knee Arthroplasy (TKA) femoral comportment installation position, Range of Motion (ROM) failure and several problems may arise. The aim of this study was to evaluate anterior bowing of the Japanese femur and to assess the adequacy of TKA femoral comportment installation position.

METHODS

We analyzed 76 normal Japanese and 97 TKA patients. (June 2014-June 2015) The average age of the normal subjects was 62.0±20.90 (24–88) years old and the average of TKA subjects was 73.6±7.9 (53–89) years old. First we defined and measured the anterior curvature and the posterior condylar offset (PCO) in normal japanese femurs. Then in TKA patients we set the implant as same angle of the component. Third, we measured the post operative anterior curvature and PCO. Then calculated the anterior curvature difference and PCO differences and preformed statistical analysis with ROM.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 65 - 65
1 Jan 2016
Terada S Nakane K Yamamoto T Niwa S
Full Access

In performing posterior cruciate ligament- retaining total knee arthroplasty (CR-TKA), the original surgical instrument was devised to obtain the range of motion and stability of the knee joint adequate for daily life of Japanese people. We have presumed the tentative joint line as intercondylar notch point of the distal femur, and performed surgery using surface replacement to resect metal width of the femoral component for the distal femur by setting the knee to the original position based on understanding of the shape of anterior curvature of the distal femur in Japanese people in case of implanting the femoral component. In order to obtain stability of the knee, we have minimally released the soft tissue and resected the anterior cruciate ligament (ACL), whereas completely preserved the posterior cruciate ligament (PCL) and maintained physiological ligament balance of the knee joint by resecting the medial condyle of the tibia (genu varus). Our surgical procedure enabled deep flexion knee (knee embracing) greater than 145 degrees in 9.7% and also allowed Japanese sitting in three different designs of total knee joints.