Controversy persists over whether cemented or uncemented fixation is more effective in reducing revision and mortality risks following primary total hip arthroplasty (THA). Despite a shift towards uncemented THA in Europe, Australia, and the US, no consensus exists on superior outcomes. This ambiguity in evidence from randomized controlled trials (RCTs) and observational studies necessitates advanced research methodologies to derive more definitive conclusions. This study investigates the causal impact of THA fixation type on 2-year and 5-year revision rates, along with 90-day mortality, utilizing a regression discontinuity (RD) design in scenarios where fixation choice is guided by patient age. Employing data from the Dutch Arthroplasty Register, we conducted a cohort study on primary THAs for osteoarthritis from 2007 to 2019. A “fuzzy” RD design was executed to compute the Local Average Treatment Effect for subjects around the age-based selection threshold for fixation type. The main outcome of interest was the revision rate at 2 years post-operation. Analysis for the 2-year revision endpoint, covering any cause, included 2,344 females and 1,671 males across 5 hospitals each, with no significant variation in revision rates observed. For the 5-year mark, 1,058 females in 3 hospitals and 214 males in 1 hospital were examined, similarly showing no significant differences. Mortality within 90 days post-operation was also investigated in 5 female and 7 male cohorts, with 2,180 and 2,145 surgeries respectively, yielding no substantial disparities. In conclusion, the RD analysis revealed no notable differences in revision rates at 2 and 5 years or in early mortality based on the fixation method used in THA. These outcomes suggest that the age-based preference for THA fixation may not influence the revision or mortality risk, underscoring the value of RD design in deriving causal insights from observational data.
Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.Aims
Methods
Arthroplasty surgery of the knee and hip is performed in two to three million patients annually. Periprosthetic joint infections occur in 4% of these patients. Debridement, antibiotics, and implant retention (DAIR) surgery aimed at cleaning the infected prosthesis often fails, subsequently requiring invasive revision of the complete prosthetic reconstruction. Infection-specific imaging may help to guide DAIR. In this study, we evaluated a bacteria-specific hybrid tracer (99mTc-UBI29-41-Cy5) and its ability to visualize the bacterial load on femoral implants using clinical-grade image guidance methods.
99mTc-UBI29-41-Cy5 specificity for Aims
Methods
Here we used a mature seven-day biofilm model of Mature biofilms of Aims
Methods
The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs). A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively.Aims
Methods
Induction heating is a noninvasive, nonantibiotic treatment modality that can potentially be used to cause thermal damage to the bacterial biofilm on the metal implant surface. The purpose of this study was to determine the effectiveness of induction heating on killing
Aims
Methods
Prosthetic joint infection (PJI) is a devastating complication following total joint arthroplasty. Non-contact induction heating of metal implants is a new and emerging treatment for PJI. However, there may be concerns for potential tissue necrosis. It is thought that segmental induction heating can be used to control the thermal dose and to limit collateral thermal injury to the bone and surrounding tissues. The purpose of this study was to determine the thermal dose, for commonly used metal implants in orthopaedic surgery, at various distances from the heating centre (HC). Commonly used metal orthopaedic implants (hip stem, intramedullary nail, and locking compression plate (LCP)) were heated segmentally using an induction heater. The thermal dose was expressed in cumulative equivalent minutes at 43°C (CEM43) and measured with a thermal camera at several different distances from the HC. A value of 16 CEM43 was used as the threshold for thermal damage in bone.Objectives
Methods
Infection of implants is a major problem in elective and trauma surgery. Heating is an effective way to reduce the bacterial load in food preparation, and studies on hyperthermia treatment for cancer have shown that it is possible to heat metal objects with pulsed electromagnetic fields selectively (PEMF), also known as induction heating. We therefore set out to answer the following research question: is non-contact induction heating of metallic implants effective in reducing bacterial load Titanium alloy cylinders (Ti6Al4V) were exposed to PEMF from an induction heater with maximum 2000 watts at 27 kHz after being contaminated with five different types of micro-organisms: Objectives
Methods
An important measure for the diagnosis and monitoring of knee osteoarthritis is the minimum joint space width (mJSW). This requires accurate alignment of the x-ray beam with the tibial plateau, which may not be accomplished in practice. We investigate the feasibility of a new mJSW measurement method from stereo radiographs using 3D statistical shape models (SSM) and evaluate its sensitivity to changes in the mJSW and its robustness to variations in patient positioning and bone geometry. A validation study was performed using five cadaver specimens. The actual mJSW was varied and images were acquired with variation in the cadaver positioning. For comparison purposes, the mJSW was also assessed from plain radiographs. To study the influence of SSM model accuracy, the 3D mJSW measurement was repeated with models from the actual bones, obtained from CT scans.Objectives
Materials and Methods
Wear of polyethylene inserts plays an important role in failure
of total knee replacement and can be monitored Before revision, the minimum joint space width values and their
locations on the insert were measured in 15 fully weight-bearing
radiographs. These measurements were compared with the actual minimum
thickness values and locations of the retrieved tibial inserts after
revision. Introduction
Method
Traumatic brachial plexus injury causes severe functional impairment
of the arm. Elbow flexion is often affected. Nerve surgery or tendon
transfers provide the only means to obtain improved elbow flexion.
Unfortunately, the functionality of the arm often remains insufficient.
Stem cell therapy could potentially improve muscle strength and
avoid muscle-tendon transfer. This pilot study assesses the safety
and regenerative potential of autologous bone marrow-derived mononuclear
cell injection in partially denervated biceps. Nine brachial plexus patients with insufficient elbow flexion
(i.e., partial denervation) received intramuscular escalating doses
of autologous bone marrow-derived mononuclear cells, combined with
tendon transfers. Effect parameters included biceps biopsies, motor
unit analysis on needle electromyography and computerised muscle tomography,
before and after cell therapy.Objectives
Methods
To define Patient Acceptable Symptom State (PASS) thresholds
for the Oxford hip score (OHS) and Oxford knee score (OKS) at mid-term
follow-up. In a prospective multicentre cohort study, OHS and OKS were collected
at a mean follow-up of three years (1.5 to 6.0), combined with a
numeric rating scale (NRS) for satisfaction and an external validation
question assessing the patient’s willingness to undergo surgery
again. A total of 550 patients underwent total hip replacement (THR)
and 367 underwent total knee replacement (TKR).Objectives
Methods
Electronic forms of data collection have gained interest in recent
years. In orthopaedics, little is known about patient preference
regarding pen-and-paper or electronic questionnaires. We aimed to
determine whether patients undergoing total hip (THR) or total knee
replacement (TKR) prefer pen-and-paper or electronic questionnaires
and to identify variables that predict preference for electronic
questionnaires. We asked patients who participated in a multi-centre cohort study
investigating improvement in health-related quality of life (HRQoL)
after THR and TKR using pen-and-paper questionnaires, which mode
of questionnaire they preferred. Patient age, gender, highest completed
level of schooling, body mass index (BMI), comorbidities, indication
for joint replacement and pre-operative HRQoL were compared between
the groups preferring different modes of questionnaire. We then
performed logistic regression analyses to investigate which variables
independently predicted preference of electronic questionnaires.Objectives
Methods
Symptoms of obstetric brachial plexus injury (OBPI) vary widely
over the course of time and from individual to individual and can
include various degrees of denervation, muscle weakness, contractures,
bone deformities and functional limitations. To date, no universally
accepted overall framework is available to assess the outcome of patients
with OBPI. The objective of this paper is to outline the proposed
process for the development of International Classification of Functioning,
Disability and Health (ICF) Core Sets for patients with an OBPI. The first step is to conduct four preparatory studies to identify
ICF categories important for OBPI: a) a systematic literature review
to identify outcome measures, b) a qualitative study using focus
groups, c) an expert survey and d) a cross-sectional, multicentre
study. A first version of ICF Core Sets will be defined at a consensus
conference, which will integrate the evidence from the preparatory
studies. In a second step, field-testing among patients will validate this
first version of Core Sets for OBPI.Background
Methods
The Kaplan-Meier estimation is widely used in orthopedics to
calculate the probability of revision surgery. Using data from a
long-term follow-up study, we aimed to assess the amount of bias
introduced by the Kaplan-Meier estimator in a competing risk setting. We describe both the Kaplan-Meier estimator and the competing
risk model, and explain why the competing risk model is a more appropriate
approach to estimate the probability of revision surgery when patients
die in a hip revision surgery cohort. In our study, a total of 62 acetabular
revisions were performed. After a mean of 25 years, no patients
were lost to follow-up, 13 patients had undergone revision surgery
and 33 patients died of causes unrelated to their hip.Objectives
Methods
The aim of this study was on the one hand to compare the fixation of a posterior stabilised prosthesis (PS) and a PCL retaining mobile bearing design (Interax, How-medica Osteonics, Rutherfort, USA) and on the other hand to measure the mobility of the mobile bearing. All measurements were carried out by means of Roentgen Stereophotogrammetric Analysis (RSA-CMS, Medis, Netherlands). Thirty-three patients with a total of forty-two consecutive primary cemented TKA were included in a prospective, randomised study at Leiden University Medical Centre. There were no significant differences among the two groups with regard to age (66. 5 ± 12. 1 years). The pre-operative Knee Society Score did not differ significantly between the two groups. At the one-year follow-up the PS group showed a significantly lower function score (p=0. 04) compared to the mobile bearing group. At the one-year follow-up evaluation, the micromotion of the PS-components and the mobile bearing components were not significantly different. The PS-tibial components subsided −0. 003 ± 0. 192 mm and the mobile bearing knee tibial components subsided 0. 057 ± 0. 082 mm. The PS tibial component showed a higher variability in the migration results indicating a number of PS with rather large micromotion. For three patients, the The wide range of kinematic patterns of mobile bearings during flexion that is observed in fluoroscopic studies is also observed in this study. A possible positive effect of mobile bearing movement may be found in the smaller variability of the micromotion of the mobile-bearing knees compared to the PS knees. The assumption was that shear forces in tibial bones implanted with a mobile bearing prosthesis would be better dissipated from the prosthesis-bone interface resulting in less micromotion. The kinematics of an additional number of mobile bearing knees -already included in the micro-motion study- will have to be assessed in order to determine the relation between mobility and micromotion. Mobile bearing, Posterior Stabilised, RSA, Kinematics