Mumme T Marx R Mueller-Rath R Andereya S Wirtz D
Full Access

Introduction: Aseptic loosening of cemented total knee arthroplasties is still an unsolved problem. In this regard the adhesion strength of the metal-bone cement interface is of major interest.

Material und Methods: Cemented tibial components coated with a silica/silane interlayer system (n=8) were dynamically loaded within a knee-simulator (DIN ISO 14243). After loading, the components were cut by “high pressure water jet technique” (Fraunhofer Institute for Production Technology, Aachen, Germany) into 10 slices (thickness 5 mm each) parallel to the shaft axis according to a standardised protocol. To evaluate the metal-bone cement interface with regard to gaps and cement failure, the tibial slices were analysed by light and fluorescent microscopy. These data were matched with uncoated components (n=8).

Results: The coated tibial components yielded a significant reduction of gaps in the metal-bone cement interface (p < 0.05) as well as a highly significant reduction of cement mantle failure (p < 0.001).

Conclusion: With the help of the silica/silane coating, gaps in the metal-bone cement interface with consecutive early cement mantle failure due to mechanical overstressing can be significantly reduced.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 190 - 190
1 Mar 2008
Wirtz D Mumme T Schuh A Gohlke F Carl H Zeiler G Forst R
Full Access

Background: The aim of this prospective multi-center study was to evaluate the clinical and radiological results of a total of 314 uncemented femoral stem revisions using the modular MRP-titanium system.

Methods: 305 patients (111 males, 194 females, mean age 67.7) with 314 MRP-titanium systems were followed-up for a meantime of 3.2 years (1 to 9 years). Pre- and post-operatively all patients were clinically documented using the Harris hip score. Radiologically, the preoperative bony defects were assessed by the Paprosky classification. Post-operatively, periprosthetic bone remodeling was evaluated on the basis of radiographic evidence of bone apposition or resorption.

The modular MRP-titanium system has proven to be valuable in quite problematic cases of hip revision arthroplasty with extensive femoral defects. The system allows intraoperative adaptation of implant length and antetorsion angle to the actual situation, a feature not provided by non-modular femoral revision implants.