Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 516 - 516
1 Dec 2013
Sabesan V Callanan M Sharma V Ghareeb G Moravek J Wiater JM
Full Access

Background

There has been increased focus on understanding the risk factors associated with scapular notching in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the effect of scapular morphology and surgical technique on the occurrence of scapular notching using the notching index as a comprehensive predictive tool.

Methods

Ninety-one patients treated with a primary RSA were followed for a minimum of 24 months. Using a previously published notching index formula ((PSNA × 0.13) + (PGRD)), a notching index value for all patients was calculated. Radiographic assessment of patients were grouped by Nerot grade of scapular notching, group mean differences for prosthetic scapular neck angle (PSNA), peg glenoid rim distance (PGRD), preoperative scapular neck angle (SNA), notching index and clinical outcomes were compared.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 150 - 150
1 Dec 2013
Wiater B Moravek J Pinkas D Koueiter D Maerz T Marcantonio D Wiater JM
Full Access

Introduction:

Reverse total shoulder arthroplasty (RTSA) has become instrumental in relieving pain and returning function to patients with end-stage rotator cuff disease. A distalized and medialized center of rotation in addition to a semi-constrained implant design allows the deltoid to substitute for the non-functioning rotator cuff. The purpose of this study was to examine the relationship between specific deltoid and rotator cuff muscle parameters and functional outcomes following RTSA.

Methods:

Patients undergoing RTSA by a single surgeon were enrolled in a prospective, IRB approved RTSA outcomes registry. Inclusion criteria were diagnosis of cuff tear arthropathy or massive rotator cuff tear, a minimum 2-year follow-up, and a preoperative shoulder MRI. We excluded patients undergoing revision arthroplasty, fracture, and a history of previous open shoulder surgery. For the 28 patients meeting our criteria, the cross-sectional area (CSA) of the anterior, middle, and posterior deltoid were measured on an axial MRI (Figure 1). Fatty infiltration (FI) of the deltoid, supraspinatus (SS), infraspinatus (IS), teres minor, and subscapularis were assessed on sagittal T1-MRI quantitatively via image processing and qualitatively on the 5-point Fuchs scale by a fellowship-trained musculoskeletal radiologist. Outcome measures included active forward elevation (aFE), active external rotation (aER), active internal rotation (aIR), strength in abduction, Constant-Murley score (CMS), Subjective Shoulder Value (SSV), Visual Analogue Scale (VAS) pain, and American Shoulder and Elbow Surgeons (ASES) total and ASES activities of daily living (ADL) scores as assessed by a trained, clinical research nurse. Correlation of deltoid CSA and FI with outcomes measures was analyzed with a Spearman rank correlation coefficient (ρ) with significance at P < .05.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 383 - 383
1 Dec 2013
Kurdziel M Peers S Moravek J Budge M Newton M Baker K Wiater JM
Full Access

Purpose:

Although short term outcomes of reverse total shoulder arthroplasty (rTSA) have been promising, long-term success may be limited due to complications, including scapular notching. Scapular notching has been explained primarily as a mechanical erosion, however, generation of wear debris may lead to further biologic changes contributing to the severity of scapular notching. Highly cross-linked ultra-high molecular weight polyethylene (UHMWPE) has been used routinely in constrained joint applications such as total hip arthroplasty for reduction of wear debris particles. Although rTSA shares similarity in design conformity, conventional UHMWPE remains the gold standard.

Methods:

A commercially available hip simulator was converted to a 12-station rTSA wear simulator. Conventional and highly cross-linked UHMWPE humeral liners were subjected to 5,000,000 cycles of alternating abduction-adduction and flexion-extension loading profiles. Every 250,000 cycles, liners were evaluated with gravimetric wear measurements and test serum was collected for morphological characterization of wear particles.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 482 - 482
1 Dec 2013
Wiater B Moravek J Pinkas D Budge M Koueiter D Marcantonio D Wiater JM
Full Access

Introduction:

Studies have demonstrated both clinical and radiological success of reverse shoulder arthroplasty (RTSA), with follow-up approaching 10-years. To date, most RTSA studies involve cemented fixation of the humeral components, and most involving uncemented RTSAs have used implants not necessarily designed for bony ingrowth. Cementless fixation utilizing proximally porous-coated (PPC) femoral implants has shown long term survivorship approaching 99% at greater than 10-years follow-up in total hip arthroplasty. Currently, the number of commercially available PPC RTSA implants is steadily growing, but there has been no published study examining clinical and radiographic outcomes in PPC, press-fit humeral stems. We hypothesized that the clinical and radiographic results of uncemented RTSA utilizing a PPC humeral stem would be similar to cemented RTSA stems when followed for at least 2-years.

Methods:

A prospective, IRB approved RTSA outcomes registry with 261 patients that underwent RTSA by one fellowship-trained orthopaedic surgeon between 2005 and 2008 was reviewed. Inclusion criteria were diagnosis of cuff tear arthropathy or severe rotator cuff deficiency refractory to all other treatments, and minimum 2-year clinical and radiographic follow-up. Exclusion criteria were proximal humeral fractures, glenohumeral instability, rheumatoid arthritis, incomplete follow-up, and revision arthroplasty. Outcome measures included active forward elevation (aFE), active external rotation (aER), active internal rotation (aIR), Constant-Murley score (CS), Subjective Shoulder Value (SSV), visual analogue scale (VAS) pain, and American Shoulder and Elbow Surgeons (ASES) score. Radiographs at 2 weeks, 3 months, 1 year, 2 years and yearly thereafter were evaluated for humeral component position, osteolysis, humeral component radiolucent lines (RLLs), stress shielding, and scapular notching. Statistical analysis was conducted by an independent institutional statistician.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 481 - 481
1 Dec 2013
Kurdziel M Wiater B Moravek J Pinkas D Wiater JM
Full Access

Purpose:

Glenoid loosening persists as a common cause of anatomic total shoulder arthroplasty (TSA) failure. Considering radiographic evidence of loosening as an endpoint, TSA has a reported survivorship of only 51.5% at 10 years. Component loosening may be related to cementation and it is postulated that poor cement penetration and heat-induced necrosis may partially be responsible. There is a growing interest among surgeons to minimize or abandon cement fixation and rely on biologic fixation to the polyethylene for long-term fixation. De Wilde et al. reported promising early clinical and radiographic results using a pegged, all-polyethylene ingrowth glenoid design implanted without cement. The goal of this study was to compare glenoid micromotion in an all-polyethylene, centrally fluted pegged glenoid using 3 cement fixation techniques.

Materials and Methods:

Glenoid components (Anchor Peg Glenoid, Depuy Orthopaedics, Warsaw, IN, USA) (Figure 1) were implanted in polyurethane foam testing blocks with 3 different fixation methods (n = 5 per group). Group I glenoids were implanted with interference fit fixation with no added cement. Group II was implanted with a hybrid fixation, where only the peripheral pegs were cemented. Group III glenoids were fully cemented for implantation. Glenoid loosening was characterized according to ASTM Standard F-2028. The glenoid component and a 44 mm humeral head were mounted to a materials testing frame (858 Mini Bionix II, MTS Crop., Eden Prairie, MN, USA) with a 750N applied joint compressive force (Figure 1). A humeral head subluxation displacement of ± 0.5 mm was experimentally calculated as a value that simulates glenoid rim loading that may occur at higher load activities. For characterization of glenoid loosening, the humeral head was cycled 50,000 times along the superior-inferior glenoid axis, simulating approximately 5 years of device service. Glenoid distraction, compression, and superior-inferior glenoid migration were recorded with two differential variable reluctance transducers fixed to the glenoid prosthesis.