Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 6 - 6
10 May 2024
Zaidi F Bolam S Goplen C Yeung T Lovatt M Hanlon M Munro J Besier T Monk A
Full Access

Introduction

Robotic-assisted total knee arthroplasty (TKA) has demonstrated significant benefits, including improved accuracy of component positioning compared to conventional jig-based TKA. However, previous studies have often failed to associate these findings with clinically significant improvements in patient-reported outcome measures (PROMs). Inertial measurement units (IMUs) provide a more nuanced assessment of a patient's functional recovery after TKA. This study aims to compare outcomes of patients undergoing robotic-assisted and conventional TKA in the early postoperative period using conventional PROMS and wearable sensors.

Method

100 patients with symptomatic end-stage knee osteoarthritis undergoing primary TKA were included in this study (44 robotic-assisted TKA and 56 conventional TKA). Functional outcomes were assessed using ankle-worn IMUs and PROMs. IMU- based outcomes included impact load, impact asymmetry, maximum knee flexion angle, and bone stimulus. PROMs, including Oxford Knee Score (OKS), EuroQol-Five Dimension (EQ-5D-5L), EuroQol Visual Analogue Scale (EQ-VAS), and Forgotten Joint Score (FJS-12) were evaluated at preoperative baseline, weeks 2 to 6 postoperatively, and at 3-month postoperative follow-up.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 13 - 13
23 Feb 2023
Tay M Monk A Frampton C Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand and University of Otago, Christchurch, New Zealand

The Oxford Knee Score (OKS) is a 12-item questionnaire used to track knee arthroplasty outcomes. Validation of such patient reported outcome measures is typically anchored to a single question based on patient ‘satisfaction’, however risk of subsequent revision surgery is also an important outcome measure. The OKS can predict subsequent revision risk within two years, however it is not known which item(s) are the strongest predictors. Our aim was to identify which questions were most relevant in the prediction of subsequent knee arthroplasty revision risk.

All primary TKAs (n=27,708) and UKAs (n=8,415) captured by the New Zealand Joint Registry between 1999 and 2019 with at least one OKS response at six months, five years or ten years post-surgery were included. Logistic regression and receiver operating characteristics (ROC) curves were used to assess prediction models at six months, five years and ten years.

Q1 ‘overall pain’ was the strongest predictor of revision within two years (TKA: 6 months, odds ratio (OR) 1.37; 5 years, OR 1.80; 10 years, OR 1.43; UKA: 6 months, OR 1.32; 5 years, OR 2.88; 10 years, OR 1.85; all p<0.05). A reduced model with just three questions (Q1, Q6 ‘limping when walking’, Q10 ‘knee giving way’) showed comparable or better diagnostic ability with the full OKS (area under the curve (AUC): TKA: 6 months, 0.77 vs. 0.76; 5 years, 0.78 vs. 0.75; 10 years, 0.76 vs. 0.73; UKA: 6 months, 0.80 vs. 0.78; 5 years: 0.81 vs. 0.77; 10 years, 0.80 vs. 0.77).

The three questions on overall knee pain, limping when walking, and knee ‘giving way’ were the strongest predictors of subsequent revision within two years. Attention to the responses for these three key questions during follow-up may allow for prompt identification of patients most at risk of revision.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 78 - 78
23 Feb 2023
Bolam S Tay M Zaidi F Sidaginamale R Hanlon M Munro J Monk A
Full Access

The introduction of robotics for total knee arthroplasty (TKA) into the operating theatre is often associated with a learning curve and is potentially associated with additional complications. The purpose of this study was to determine the learning curve of robotic-assisted (RA) TKA within a multi-surgeon team.

This prospective cohort study included 83 consecutive conventional jig-based TKAs compared with 53 RA TKAs using the Robotic Surgical Assistant (ROSA) system (Zimmer Biomet, Warsaw, Indiana, USA) for knee osteoarthritis performed by three high-volume (> 100 TKA per year) orthopaedic surgeons. Baseline characteristics including age, BMI, sex and pre-operative Kellgren-Lawrence grade were well-matched between the conventional and RA TKA groups. Cumulative summation (CUSUM) analysis was used to assess learning curves for operative times for each surgeon. Peri-operative and delayed complications were reviewed.

The CUSUM analysis for operative time demonstrated an inflexion point after 5, 6 and 15 cases for each of the three surgeons, or 8.7 cases on average. There were no significant differences (p = 0.53) in operative times between the RA TKA learning (before inflexion point) and proficiency (after inflexion point) phases. Similarly, the operative times of the RA TKA group did not differ significantly (p = 0.92) from the conventional TKA group. There was no discernible learning curve for the accuracy of component planning using the RA TKA system. The average length of post-operative follow-up was 21.3 ± 9.0 months. There was no significant difference (p > 0.99) in post-operative complication rates between the groups.

The introduction of the RA TKA system was associated with a learning curve for operative time of 8.7 cases. Operative times between the RA TKA and conventional TKA group were similar. The short learning curve implies this RA TKA system can be adopted relatively quickly into a surgical team with minimal risks to patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 77 - 77
23 Feb 2023
Bolam S Konar S Gamble G Paine S Dalbeth N Monk A Coleman B Cornish J Munro J Musson D
Full Access

Traumatic rotator cuff injuries can be a leading cause of prolonged shoulder pain and disability, and contribute to significant morbidity and healthcare costs. Previous studies have shown evidence of socio-demographic disparities with these injuries. The purpose of this nationwide study was to better understand these disparities based on ethnicity, sex, and socio-economic status, in order to inform future healthcare strategies.

Accident Compensation Corporation (ACC) is a no-fault comprehensive compensation scheme encompassing all of Aotearoa/New Zealand (population in 2018, 4.7 million). Using the ACC database, traumatic rotator cuff injuries were identified between January 2010 and December 2018. Injuries were categorized by sex, ethnicity, age and socioeconomic deprivation index of the claimant.

During the 9-year study period, there were 351,554 claims accepted for traumatic rotator cuff injury, which totalled over $960 million New Zealand Dollars. The greatest proportion of costs was spent on vocational support (49.8%), then surgery (26.3%), rehabilitation (13.1%), radiology (8.1%), general practitioner (1.6%) and “Other” (1.1%). Asian, Māori (Indigenous New Zealanders), and Pacific peoples were under-represented in the age-standardized proportion of total claims and had lower rates of surgery than Europeans. Māori had higher proportion of costs spent on vocational support and lower proportions spent on radiology, rehabilitation and surgery than Europeans. Males had higher number and costs of claims and were more likely to have surgery than females. There were considerably fewer claims from areas of high socio-economic deprivation.

This large nation-wide study demonstrates the important and growing economic burden of rotator cuff injuries. Indirect costs, such as vocational supports, are a major contributor to the cost suggesting improving treatment and rehabilitation protocols would have the greatest economic impact. This study has also identified socio-demographic disparities which need to be addressed in order to achieve equity in health outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 14 - 14
23 Feb 2023
Tay M Monk A Frampton C Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand and University of Otago, Christchurch, New Zealand

Patient reported outcome measures (PROMs) are predictors of knee arthroplasty revision. Unicompartmental knee arthroplasty (UKA) is effective for patients with the correct indications, however has higher revision rates than total knee arthroplasty (TKA). Different revision thresholds for the procedures have been postulated. Our aims were to investigate: 1) if PROMs could predict knee arthroplasty revision within two years of the score at six months, five years and ten years follow-up, and 2) if revision ‘thresholds’ differed between TKA and UKA.

All TKAs and UKAs captured by the New Zealand Joint Registry between 1999 and 2019 with at least one OKS response at six months (TKA n=27,708, UKA n=8,415), five years (TKA n=11,519, UKA n=3,365) or ten years (TKA n=6,311, UKA n=1,744) were included. were propensity-score matched 2:1 with UKAs for comparison of revision thresholds.

Logistic regression indicated that for every one-unit decrease in OKS, the odds of TKA and UKA revision decreased by 10% and 11% at six months, 10% and 12% at five years and 9% and 5% at ten years. Fewer TKA patients with ‘poor’ outcomes (≤25) subsequently underwent revision compared with UKA at six months (5.1% vs. 19.6%, p<0.001), five years (4.3% vs. 12.5%, p<0.001) and ten years (6.4%vs. 15.0%, p=0.02). Compared with TKA, UKA patients were 2.5 times more likely to undergo revision for ‘unknown’ reasons, bearing dislocations and disease progression.

The OKS is a strong predictor of subsequent knee arthroplasty revision within two years of the score from early to late term. A lower revision threshold was found with UKA when compared with a matched TKA cohort. Higher revision rates of UKA are associated with both lower clinical thresholds for revision and additional modes of UKA failure.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 16 - 16
23 Feb 2023
Tay M Bolam S Coleman B Munro J Monk A Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand

Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up.

Patient, implant and revision details were recorded through clinical and radiological review for 2,137 consecutive patients undergoing primary medial UKA across Auckland, Canterbury, Counties Manukau and Waitematā DHB between 2000 and 2017. Revision reasons were determined from review of clinical, laboratory, and radiological records for each patient using a standardised protocol. To ensure complete follow-up data was cross-referenced with the New Zealand Joint Registry to identify patients undergoing subsequent revision outside the hospitals. Implant survival, revision risk and revision reasons were analysed using Cox proportional-hazards and competing risk analyses.

Implant survivorship at 15 years was comparable for cemented fixed-bearing (cemFB; 91%) and uncemented mobile-bearing (uncemMB; 91%), but lower for cemented mobile-bearing (cemMB; 80%) implants. There was higher incidence of aseptic loosening with cemented implants (3–4% vs. 0.4% uncemented, p<0.01), osteoarthritis (OA) progression with cemMB implants (9% vs. 3% cemFB/uncemMB; p<0.05) and bearing dislocations with uncemMB implants (3% vs. 2% cemMB, p=0.02). Compared with the oldest patients (≥75 years), there was a nearly two-fold increase in risk for those aged 55–64 (hazard ratio 1.9; confidence interval 1.1-3.3, p=0.03). No association was found with gender, BMI or ASA.

Cemented mobile-bearing implants and younger age were linked to lower implant survivorship. These were associated with disease progression and bearing dislocations. The use of cemented fixed-bearing and uncemented mobile-bearing designs have superior comparable long-term survivorship.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 80 - 80
23 Feb 2023
Bolam S Park Y Konar S Callon K Workman J Monk A Coleman B Cornish J Vickers M Munro J Musson D
Full Access

We hypothesised that diet-induced obesity (DIO) would result in inferior enthesis healing in a rat model of rotator cuff (RC) repair and that dietary intervention in the peri-operative period would improve enthesis healing.

A total of 78 male Sprague-Dawley rats were divided into three weight-matched groups from weaning and fed either: control diet (CD), high-fat diet (HFD), or HFD until surgery, then CD thereafter (HF-CD). After 12 weeks, the left supraspinatus tendon was detached, followed by immediate surgical repair. At 2 and 12 weeks post-surgery, animals were culled, and RCs harvested for biomechanical and histological evaluation. Body composition and metabolic markers were assessed via DEXA and plasma analyses, respectively.

DIO was established in the HFD and HF-CD groups before surgery and subsequently reversed in the HF-CD group after surgery. Histologically, the appearance of the repaired entheses was poorer in both the HFD and HF-CD groups compared with the CD group at 12 weeks after surgery, with semiquantitative scores of 6.2 (P<0.01), 4.98 (P<0.01), and 8.7 of 15, respectively. The repaired entheses in the HF-CD group had a significantly lower load to failure (P=0.03) at 12 weeks after surgery compared with the CD group, while the load to failure in the HFD group was low but not significantly different (P=0.10). Plasma leptin were negatively correlated with histology scores and load to failure at 12 weeks after surgery.

DIO impaired enthesis healing in this rat RC repair model, with inferior biomechanical and histological outcomes. Restoring normal weight with dietary change after surgery did not improve healing outcomes. Circulating levels of leptin significantly correlated with poor healing outcomes. This pre-clinical rodent model demonstrates that obesity is a potentially modifiable factor that impairs RC healing and increases the risk of failure after RC surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 68 - 68
10 Feb 2023
Zaidi F Bolam S Yeung T Besier T Hanlon M Munro J Monk A
Full Access

Patient-reported outcome measures (PROMs) have failed to highlight differences in function or outcome when comparing knee replacement designs and implantation techniques. Ankle-worn inertial measurement units (IMUs) can be used to remotely measure and monitor the bi-lateral impact load of patients, augmenting traditional PROMs with objective data. The aim of this study was to compare IMU-based impact loads with PROMs in patients who had undergone conventional total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA), and robotic-assisted TKA (RA-TKA).

77 patients undergoing primary knee arthroplasty (29 RA-TKA, 37 TKA, and 11 UKA) for osteoarthritis were prospectively enrolled. Remote patient monitoring was performed pre-operatively, then weekly from post-operative weeks two to six using ankle-worn IMUs and PROMs. IMU-based outcomes included: cumulative impact load, bone stimulus, and impact load asymmetry. PROMs scores included: Oxford Knee Score (OKS), EuroQol Five-dimension with EuroQol visual analogue scale, and the Forgotten Joint Score.

On average, patients showed improved impact load asymmetry by 67% (p=0.001), bone stimulus by 41% (p<0.001), and cumulative impact load by 121% (p=0.035) between post-operative week two and six. Differences in IMU-based outcomes were observed in the initial six weeks post-operatively between surgical procedures. The mean change scores for OKS were 7.5 (RA-TKA), 11.4 (TKA), and 11.2 (UKA) over the early post-operative period (p=0.144). Improvements in OKS were consistent with IMU outcomes in the RA-TKA group, however, conventional TKA and UKA groups did not reflect the same trend in improvement as OKS, demonstrating a functional decline.

Our data illustrate that PROMs do not necessarily align with patient function, with some patients reporting good PROMs, yet show a decline in cumulative impact load or load asymmetry. These data also provide evidence for a difference in the functional outcome of TKA and UKA patients that might be overlooked by using PROMs alone.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 38 - 38
10 Feb 2023
Batinica B Bolam S Zhu M D'Arcy M Peterson R Young S Monk A Munro J
Full Access

Little information exists regarding optimal tibial stem usage in revision total knee arthroplasty (rTKA) utilising a tibial trabecular metal (TM) cone. The purpose of this study was to compare 1) functional outcomes, 2) radiographic outcomes, and 3) implant survivorship in rTKA utilising TM cones combined with either short stems (SS) or long stems (LS) at minimum two-years clinical follow-up.

In this retrospective, multi-centre study, patients undergoing TM cone utilising rTKA between 2008 and 2019 were included. Patients were divided into: SS group (no diaphyseal engagement), and LS group (diaphyseal engagement). All relevant clinical charts and post-operative radiographs were examined. Oxford Knee Score (OKS) and EuroQol-5D (EQ-5D-5L) data were collected at most recent follow-up.

In total, 44 patients were included: 18 in the SS group and 26 in the LS group. The mean time of follow-up was 4.0 years. Failure free survival was 94.5% for the SS group and 92.3% for the LS group. All failures were for prosthetic joint infections managed with debridement, antibiotics, and implant retention. At most recent follow-up, 3 patients demonstrated radiographic signs of lucency (1 SS 2 LS, p = 1) and the mean OKS were 37 ± 4 and 36 ± 6 (p = 0.73) in the SS and LS groups, respectively.

Tibial SS combined with TM cones performed as well as LS in rTKA at minimum two-years follow-up. A tibial SS in combination with a TM cone is a reliable technique to achieve stable and durable fixation in rTKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_15 | Pages 17 - 17
1 Sep 2016
Nogaro M Monk A Wittmann U Buckingham R
Full Access

The aim was to determine reliability in treatment threshold based on USS angular measurements between observers involved in the DDH hip screening programme at the NOC and assess the effect of image orientation on the accuracy of these measurements.

3 independent observers measured alpha and beta angles on bilateral hips in 10 consecutive patients seen in the DDH hip screening clinic. All scans were performed by a single radiographer and observers used the same set of USS images for a given patient. Each observer measured alpha and beta angles a total of 4 times: conventional ultrasound image projection (with the ilium horizontal) (round 1), Graf's anatomical projection (round 2), and both techniques repeated 1 month later (round 3 and 4 respectively) to assess intra-observer reliability. To determine its effect on treatment threshold taking into account alpha and beta angles and patient's age, the consistency between observers' management recommendations was evaluated for each round. Possible outcomes were: 1) patient discharged, 2) no treatment needed yet, but follow-up required, 3) start treatment.

Intra-observer reliability for conventional projection was moderate (Kappa 0.58), and improved for anatomical projection (Kappa 0.65). Inter-observer reliability, as a surrogate measure of consistency in management recommendations between observers, ranged from fair to moderate across the 4 rounds (Kappa 0.30 – 0.50). However, contrary to previous recommendations, reliability was better with conventional projection (Kappa 0.41 (95% CI 0.11–0.72)) compared to anatomical projection (Kappa 0.36 (95% CI −0.01–0.73)). The overall agreement in management recommendations, pooling all results across 4 rounds, was 51.3% (Kappa 0.39 (95%CI 0.15–0.63)).

This audit supports the argument that anatomical image projection improves intra-observer consistency. However, as with all USS measurements, angular measurements were highly user dependent and treatment threshold based on USS may not be as consistent as anticipated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 49 - 49
1 Jan 2016
Monk A Mellon S Chen M Beard D Gill H Murray D
Full Access

Introduction

Knee arthroplasty is an effective intervention for painful arthritis when conservative measures have failed. Despite recent advances in component design and implantation techniques, a significant proportion of patients experience problems relating to the patella-femoral joint (PFJ).

Detailed knowledge of the shape and orientation of the normal and replaced femoral trochlea groove is critical when considering potential causes of anterior knee pain. Furthermore, to date it has proved difficult to establish a diagnosis due to shortcomings in current imaging techniques for obtaining satisfactory coronal plane motion data of the patella in the replaced knee.

The aim of this study was to correlate the trochlea shape of normal and replaced knees with corresponding coronal plane PFJ kinematic data.

Method

Bony and cartilagenous trochlea geometries from 3T MRI scans of 20 normal healthy volunteers were compared with both anatomical and standard total knee replacements (TKR) and patellofemoral joint replacement (PFJR) geometries. Following segmentation and standardized alignment, the path of the apex of the trochlea groove was measured using customized Matlab software. (Fig1).

Next, kinematic data of the 20 normal healthy volunteers (Normal) was compared with that of 20 TKR, and 20 PFJR patients using the validated MAUSTM system (Motion Analysis and UltraSound) comprising a 12-camera, motion capture system used to capture images of reflective markers mounted on subjects lower limbs and an ultrasound probe. A mapping between the ultrasound image and the motion capture system allows the ultrasound probe to be used to determine the locations of the patella relative to bony landmarks on the femur during a squat exercise.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_26 | Pages 10 - 10
1 Jun 2013
Monk A Chen M Mellon S Gibbons M Beard D Murray D Gill H
Full Access

Previous attempts to measure coronal plane patellofemoral kinematics following knee replacement have suffered from methodological drawbacks; the patella being obscured by the components, metal artefact and technical inaccuracies. The aim of this study was to assess whether there was any significant difference in the patellofemoral kinematics between normal, TKR and PFJR patients using the validated MAUS™ technique (combining motion analysis with ultrasound).

60 patients were recruited into three groups; normal healthy volunteers (Normal), TKR, and PFJR patients. The MAUS technique incorporates a 12 camera analysis system (providing gross alignment data for tibial and femoral segments) and an ultrasound probe (providing coordinates of bony landmarks on patella femur and tibia) during a squat exercise. 6 DOF kinematics were described between 0 and 90° flexion. The validated accuracy of the MAUS technique registering the ultrasound images within the motion capture system is 1.84 mm (2 × SD).

Movements of the Normal group were significantly different from the TKR group (p=0.03) and the PFJR group (p<0.01), whilst there was no significant difference between the TKR and PFJR groups (p=0.27).

Our data suggest that many aspects of patellofemoral kinematics are absent following TKR and PFJR, which could be addressed in future designs of knee TKR and PFJR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 263 - 263
1 Sep 2012
Monk A Grammatopoulos G Chen M Gibbons M Beard D Gill H Murray D
Full Access

Introduction

Osteoarthritis (OA) of the hip is an important cause of pain and morbidity. The mechanisms and pathogenesis of OA'sdevelopment remain unknown. Minor acetabular dysplasia and subtle variations in proximal femoral morphology are increasingly being recognized as factors that potentially compromise the joint biomechanically and lead to OA. Previous studies have shown that risk of hip OA increased as the femoral head to femoral neck ratio (HNR) decreased. Previous work has described the evolutionary change in inferior femoral neck trabecular density and geometry associated with upright stance, but no study has highlighted the evolutionary change in HNR. The aim of this study was to examine evolutionary evidence that the hominin bipedal stance has lead to alterations in HNR that would predispose humans to hip OA.

Methods

A collaboration with The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford provided specimens from the Devonian, Jurassic, Cretaceous, Miocene, Palaeolithic and Pleistocene periods to modern day. Specimens included amphibious reptiles, dinosaurs, shrews, tupaiae, lemurs, African ground apes, Lucy (A. Afarensis), H. Erectus, H. Neaderthalis and humans. Species were grouped according to gait pattern; HAKF (hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and hominin/bi-pedal. Imaging of specimens was performed using a 64 slice CT scanner. Three-dimensional skeletal geometries were segmented using MIMICS software. Anatomical measurements from bony landmarks were performed to describe changes in HNR, in the coronal plane of the different specimens over time using custom software. Measurements of HNR from the specimens were compared with HNR measurements made from AP pelvic radiographs of 119 normal subjects and 210 patients with known hip OA listed for hip arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 509 - 509
1 Sep 2012
Thomas G Hossain M Monk A Gill H Glyn-Jones S Andrew J Murray D Beard D Epos Group N
Full Access

Introduction

Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study.

Methods

A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 21 - 21
1 Jul 2012
Monk A Grammatopoulos G Chen M Gibbons C Beard D Murray D Gill H
Full Access

A femoral head/neck ratio (HNR) of less than 1.27 is associated with an increased risk of arthritis. The aim of this study was to establish whether there is evolutionary evidence that the homonin, bipedal stance has led to alterations in HNR that predispose humans to osteoarthritis (OA).

Specimens provided by The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford were grouped according to gait pattern, HAKF (Hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and homonin/bi-pedal. Specimens included those from Devonion, Triassic, Jurrasic, Cretaceous, Miocene, Paleolithic, Pleistocene periods to modern day. Three-dimensional skeletal geometries were segmented using CT images and HNR measurements were taken from coronal views. These were compared with the HNR of 119 asymptomatic human volunteers and 210 patients that had a hip joint replacement for primary OA.

Species of the HAKF group had the smallest HNR (1.10, SD:0.09). Species of the Arboreal group had significantly higher HNR (1.63, SD:0.15) in comparison to the Bipedal group (1.41, SD:0.04) (p=0.006), Human (1.33, SD:0.08) and the OA group (1.3, SD:0.09).

The range of movement associated with arboreal habitat caused an associated change in HNR. This study would suggest that the HNR peaked in the Miocene period with species that ambulated on both ground and trees. More recent homonin gait appears to have developed a smaller HNR and humans have the smallest amongst their close ancestors. Evolutionary theory would suggest that modern environmental pressures might pre-dispose future hominin evolution to OA, secondary to a further reduction in HNR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 96 - 96
1 May 2012
Monk A McKenna D Simpson D Beard D Thomas N Gill H
Full Access

The heat produced by drills, saws and PMMA cement in the handling of bone can cause thermal necrosis. Thermal necrosis could be a factor in the formation of a fibrous tissue membrane and impaired bony ingrowth into porous prostheses. This has been proposed to lead to non-union of osteotomies and fractures, the failure of the bone-cement interface and the failure of resurfacing arthroplasty.

We compared three proprietary blades (the De Soutter, the Stryker Dual Cut and the Stryker Precision) in an in-vitro setting with porcine tibiae, using thermocouples embedded in the bone below the cutting surface to measure the increases in bone temperature.

There was a significant (p=0.001) difference in the change in temperature (δT) between the blade types. The mean increase in temperature was highest for the De Soutter, 2.84°C (SD: 1.83°C, range 0.48°C to 9.30°C); mean δT was 1.81°C (SD: 1.00°C, range 0.18°C to 4.85°C) for the Precision and 1.68°C (SD: 0.95°C, range 0.24°C to 5.67°C). Performing paired tests, there was no significant difference in δT between the Precision and Dual Cut blades (p=0.340), but both these blades had significantly (p=0.003 for Precision vs De Soutter, p<0.001 for Dual Cut vs De Soutter) lower values for δT than the Dual Cut.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 505 - 505
1 Oct 2010
Monk A Beard D Dodd C Doll H Gibbons C Gill H Murray D Ostlere S Simpson D
Full Access

Patello-femoral instability (PFI) affects 40 individuals per 100,000 population and causes significant morbidity. The causes of patello-femoral instability are multi-factorial, and an isolated anatomical abnormality does not necessarily indicate instability. Patello-femoral subluxation ranges from 0% (stable patella tracking) to 100% (dislocation) and there is an established relationship between the amount of subluxation and anterior knee pain. Traditionally, magnetic resonance (MR) imaging and standard radiographs are used to guide the clinician towards a suitable corrective procedure for PFI. The multi-factorial nature of patello-femoral instability is not addressed with current imaging techniques. This study aims to address which anatomical variables assessed on MR images are most relevant to patello-femoral subluxation. This information will aid surgical decision making, particularly in selecting the most appropriate reconstructive surgery.

A retrospective analysis of MR studies of 60 patients with suspected patello-femoral instability was performed. All patients were graded for degree of subluxation using a dynamic MR scan.

The patient scans were assessed for the presence of a specific range of anatomical variables:

patella alta, (modified Insall-Salvatti)

patella type (Wiberg classification)

trochlea sulcus angles for bone and cartilage surfaces

the distance of the vastus medialis obliquis (VMO) muscle from the patella

trochlea and patella cartilage thickness

the horizontal distance between the tibial tubercle and the midpoint of the femoral trochlea (TTD)

patella engagement – the percentage of the patella height that is captured in the trochlea groove in full extension.

The Wilk’s Lambda test for multi-variate analysis was used to establish whether any relationship was present between the degree of patello-femoral instability and bony or soft tissue anatomical variables. Non-parametric statistical tests were applied across the groups and within the groups to assess their relative significance.

The following variables showed a significant relationship with patellofemoral subluxation; distance of the VMO from the patella (< 0.001), TTD (< 0.001), patella engagement (0.001), sulcus angles (0.004) and patella alta (0.005).

This study agrees with previous work showing a significant correlation between subluxation and trochlea sulcus angle and TTD.

This is the first study to establish a significant correlation between patella engagement and radiological instability. The lower the percentage engagement of the patella in the trochlea, the greater the degree of patello-femoral instability. Patella engagement showed a more significant relationship with subluxation than patella alta.

We report a new method of predicting patello-femoral instability by measuring the overlap of the patella in the trochlea groove.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 400 - 400
1 Apr 2004
Monk A Berry E Soames R Limb D
Full Access

Loosening of the glenoid component after Total Shoulder Arthroplasty is an established phenomenon with long-term follow-up studies showing radiolucency in 65% of glenoid components at 10 years (Stewart and Gray, 1997). Glenoid component designs are based on anthropometric measurements of normal shoulder joints. The purpose of this study was to study the surface anatomy of both bony and cartilaginous layers of the normal glenoid fossa in more detail.

We have developed a reproducible and inexpensive technique of surface shape assessment using laser morphometric analysis and applied this to thirty normal glenoid fossae mounted in the scapular plane. Surface analysis was carried out before and after removal of the glenoid labrum and after papain digestion of the articular cartilage allowing assessment of the skeleton alone allowing comparison with other studies using bony or cartilaginous landmarks in assessment of glenoid version. Using a specially designed program, five equi-distant lines were placed across the glenoid from which analysis of the orientation of the fossa was determined.

None of the scapulae presented a single surface that could be judged anteverted or retroverted by an amount representable by a single figure. All scapulae demonstrated a twist about the vertical axis. Two main types were identified.

Type 1 – Superior retroversion (mean 16.0 degrees) becoming progressively less to the lower pole (mean 3.0 degrees)

Type 2 – Retroverted superiorly, twisting to reach the position of maximal anteversion in the lower half of the glenoid, twisting back into more retroversion towards the lower pole. None of the specimens were morphologically equivalent to currently available glenoid prostheses. The surface shape of the glenoid is so variable that we should explore the relationship between this and the kinematics of the shoulder joint. There may be implications for the design of shoulder replacements and possibly custom prostheses.