Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 13 - 13
1 Feb 2020
Tanaka S Tei K Minoda M Matsuda S Takayama K Matsumoto T Kuroda R
Full Access

Introduction

Acquiring adaptive soft-tissue balance is one of the most important factors in total knee arthroplasty (TKA). However, there have been few reports regarding to alteration of tolerability of varus/valgus stress between before and after TKA. In particular, there is no enough data about mid-flexion stability. Based on these backgrounds, it is hypothesized that alteration of varus/valgus tolerance may influence post-operative results in TKA. The purpose of this study is an investigation of in vivo kinematic analyses of tolerability of varus/valgus stress before and after TKA, comparing to clinical results.

Materials and Methods

A hundred knees of 88 consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. The kinematic parameters of the soft-tissue balance, and amount of coronal relative movement between femur and tibia were obtained by interpreting kinematics, which display graphs throughout the range of motion (ROM) in the navigation system. Femoro-tibial alignments were recorded under the stress of varus and valgus before the procedure and after implantation of all components. In each ROM (0, 30, 60, 90, 120 degrees), the data of coronal relative movement between femur and tibia (tolerability) were analyzed before and after implantation. Furthermore, correlations between tolerability of varus/valgus and clinical improvement revealed by ROM and Knee society score (KSS) were analyzed by logistic regression analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 48 - 48
1 Mar 2017
Tei K Minoda M Shimizu T Matsuda S Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed and widely used. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femoro-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femoro-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system and tensor device intra-operatively in TKA.

Materials and Methods

Sixty-one consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. During surgery, using a tensor device, after bony cut of femur and tibia, joint gaps were assessed in 0 and 90 degrees in flexion. Then, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal and sagittal relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) in the navigation system. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with a ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p< 0.05).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 108 - 108
1 Jul 2014
Onishi Y Kawamoto T Ueha T Hara H Toda M Harada R Minoda M Morishita M Kurosaka M Akisue T
Full Access

Summary Statement

A novel transcutaneous CO2 therapy significantly enhanced the antitumor effectiveness of X-ray irradiation in human MFH xenografts The results strongly suggest that transcutaneous CO2 therapy could be a novel therapeutic tool for overcoming radioresistance in human malignancies.

Introduction

Hypoxia contributes to tumor radioresistance. In the presence of oxygen, reactive oxygen species (ROS) play crucial roles in cellular apoptosis to irradiation. We previously showed that a novel transcutaneous application of CO2 can improve hypoxia and that it induces apoptosis and decreases the expression of HIF-1α in sarcoma. Therefore, we hypothesised that a transcutaneous application of CO2 may increase radiosensitivity in sarcoma by improvement of hypoxic condition and increasing ROS production in tumors. The purpose of this study is to examine the effect of transcutaneous application of CO2 on radiosensitivity in human malignant fibrous histiocytoma (MFH) cells.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 107 - 107
1 Jul 2014
Minoda M Kawamoto T Akisue T Hara H Onishi Y Toda M Harada R Morishita M Ueha T
Full Access

Summary Statement

Survivin is a member of the inhibitor of apoptosis family, which may contribute to the progression of human MFH via inhibiting the mitochondrial apoptosis, and may be considered as a potent therapeutic target for the treatment of human MFH.

Introduction

Survivin is a member of the inhibitor of apoptosis (IAP) family, which usually expresses in the embryonic lung and fetal organs in the developmental stages, but is undetectable in normal adult tissues other than thymus, placenta, CD34+ stem cells, and basal colonic epitherial cells. However, several studies reported that survivin is highly expressed in various human malignancies, including sarcomas, and increased expression of survivin is an unfavorable prognostic marker correlating with decreased overall survival in cancer patients. We have previously reported that survivin was strongly expressed in human malignant fibrous histiocyoma (MFH), however, the roles of survivin in human MFH have not been studied. The aim of this study was to evaluate the effect of survivin inhibition on apoptotic activity in human MFH cells.