Patient-specific design (PSD) total knee arthroplasty (TKA) implants are marketed to restore neutral mechanical axis alignment (MAA) and provide better anatomic fit compared to standard off-the-shelf (OTS) TKA designs. The purpose of this study was to compare the Knee-Society scores, radiographic outcomes, and complications of PSD and OTS implants. IRB approved prospective study comparing PSD and OTS by a single surgeon. Implant design change in PSD occurred during the study leading to PSD-1 and PSD-2 subgroups. Demographic, radiographic data including MAA, coronal-tibial angle (CTA), femoro-tibial angle (FTA), tibial-slope (TS) and patella-tilt (PT), and complications were analyzed. Minimum follow-up was 2 year or until revision, and patients completed Knee-Society scores preoperatively, and postoperatively at 3-, 6-, 12-, 24 weeks and final follow up.Background/Purpose
Methods