Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 122 - 122
1 Feb 2004
Doyle T Adair A Wilson A Mawhinney I
Full Access

Aim: To assess the functional and radiological outcome of AO wrist Arthrodesis using the AO wrist fusion plate.

Method: An 8 year, independent, retrospective, radiological and functional review was performed using The DASH (Disabilities of the Arm, Shoulder and Hand questionnaire) and the Buck-Gramcko/Lohmann outcome scores.

Results: Twenty-eight patients were reviewed. The two scoring systems correlated consistently in regards to the functional outcome. However, patients with systemic disease experienced problems completing the DASH questionnaire. Mono-articular arthritis was associated with an excellent/good outcome in 95% of cases. Results for patients with systemic disease were markedly worse. There was one case of plate breakage associated with a delayed union of the second MCP joint. There was a 100% union rate, no significant post-operative infections and no tendon ruptures.

Conclusion: The short to mid term clinical outcomes for the AO wrist fusion plate are encouraging and its use can be recommended in a variety of wrist pathologies.