Grammatopoulos G Alvand A Martin H Taylor A Whitwell D Gibbons M
Full Access

The management of proximal femoral bone loss is a significant challenge in revision hip arthroplasty. A possible solution is the use of a modular proximal femur endoprosthesis (EPR). Although the survivorship and functional outcome of megaprostheses used in tumour surgery has been well described, outcome of EPRs used in revision hip surgery has received less attention. The aim of this study was to determine the 5-year outcome following proximal femur EPR and determine factors that influence it.

This was a retrospective consecutive case series of all EPRs (n=80) performed for non-neoplastic indications, by 6 surgeons, in our tertiary referral centre, between 2005–2014. Patient demographics and relevant clinical details were determined from notes. The most common indications for the use of EPRs included infection (n=40), peri-prosthetic fracture (n=12) and failed osteosynthesis of proximal femoral fractures/complex trauma (n=11). Outcome measures included complication and re-operation rates, implant survival and assessment of functional outcome using the Oxford-Hip-Score (OHS).

The mean age at surgery was 69 years and mean follow-up was 4 (0 – 11) years. The mean number of previous hip operations was 2.4 (range: 0 – 17). Twenty-five patients sustained a complication (31%), the most common being infection (n=9) and dislocation (n=4). By follow-up, further surgery was required in 18 (22%) hips, 9 of which were EPR revisions. 5-yr implant survivorship was 87% (95%CI: 76 – 98%). Mean OHS was 28 (range: 4 – 48). Inferior survival and outcome were seen in EPRs performed for the treatment of infection. Infection eradication was achieved in 34/41 with the index EPR procedure and in 40/41 hips by follow-up.

Limb salvage was achieved in all cases and acceptable complication- and re-operation rates were seen. EPRs for periprosthetic fractures and failed osteosynthesis had best outcome. We recommend the continued use of proximal femur EPR in complex revision surgery.