Although the use of stems in revision total knee arthroplasty (RTKA) enhances survival by improving the stability of implant, questions as to the optimal fixation method as well as the vertical extent of the cement, remain unanswered. This study aimed 1) to determine the correlation between the vertical extent of cement and implant loosening; and 2) to determine the minimum cementing extent for a stable implant in revision TKA with a hybrid technique. We retrospectively analyzed 109 stemmed RTKAs with average follow-up of 63 months. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. During surgery, stem was partially covered with cement beyond stem-implant junction. Stability of implant was evaluated according to the modified Knee Society Radiographic Scoring System. Cementing extent was defined as length from implant base to the end of the radiopaque line around the stem. The correlation between the vertical cementing extent and implant stability was analyzed, and the minimal vertical cementing extent for a stable implant was evaluated with a scatter plot.Purpose
Materials and Methods
Over the past twenty years, the Low Contact Stress Rotating Platform (LCS RP) showed good results. Buechel and Pappas invented the Buechel-Pappas Knee (B-P Knee) system that is a modified version of the LCS system with different material (titanium), axial rotation limiting bar and improved conformity. The purpose of this prospective randomized study was to compare the 2-year clinical outcomes between two implants in the same patients who had been operated with bilateral TKAs. We prospectively enrolled 107 patients and 18 patients were lost to follow-up. Therefore, 89 patients (178 knees; mean age, 69.8±6.0years) were included in the study. The range of motion and clinical scores such as Knee Society score (KSS), Hospital for Special Surgery score (HSS) and Western Ontario and McMaster University (WOMAC) scores were measured preoperatively and postoperatively. At each follow-up, patients also complete a Likert scale questionnaire regarding subjective pain, lightness, left-right side preference (naturalness and satisfaction) and subjective instability. There were no significant differences in all preoperative variables between the two groups(
To investigate treatment patterns and efficacy of postoperative strong opioids in patients who underwent total knee arthroplasty (TKA) in Korea A prospective, non-interventional study of 301 patients who underwent TKA and received strong opioids following patient controlled analgesia (PCA) was conducted by reviewing patient charts and diaries from 19 teaching hospitals. Clinical characteristics, strong opioid treatment patterns, efficacy of strong opioid on a scale of 0–10, and opioid-related adverse events (AEs) were investigated during hospitalization and at first outpatient visit. Safety analysis was conducted on 301 patients, and efficacy analysis was conducted on full analysis set (FAS) which consisted of all the patients who had at least 1 efficacy result among 301 patients.Purpose:
Methods:
Revision TKA using CCK prosthesis showed comparable outcome to PS prosthesis in clinical and radiological results. In revision total knee arthroplasty (TKA), the goal should be to obtain good motion, function and most importantly stability. The stability depends on remaining soft tissue and implant design. The more the ligaments retain function, the less the implant constraint is needed to achieve stability. With increased constraint, the transfer of joint reaction forces to implant-bone interface may lead to mechanical loosening of the implant. Constrained condylar knee (CCK) prosthesis provides more constraint compared with posterior stabilized (PS) prosthesis. The purpose of this study was to compare the clinical, radiological outcome and survivorship of CCK and PS prosthesis in revision TKA.Summary
Introduction
UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA.Summary
Introduction