Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans.

Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively.

Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT.

The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 54 - 54
23 Jun 2023
Shaath MK Yawman J Anderson T Avilucea F Langford J Munro M Haidukewych GJ
Full Access

Intertrochanteric fractures are common, accounting for nearly 30% of all fracture related admissions. Some have suggested that these fractures should be treated in community hospitals so as not to tax the resources of Level One trauma centers. Since many factors predictive of fixation failure are related to technical aspects of the surgery, the purpose of this study was to compare radiographic parameters after fixation comparing trauma fellowship trained surgeons to non-fellowship trained community surgeons to see if these fractures can be treated successfully in either setting.

Using our hospital system's trauma database, we identified 100 consecutive patients treated with cephalomedullary nails by traumatologists, and 100 consecutive patients treated by community surgeons. Quality of reduction, neck shaft angle (NSA), tip-to apex distance (TAD) were compared.

The mean TAD for the trauma group was 10mm compared to 21mm for the community group (p<0.001). The mean postoperative NSA for the trauma group was 133 degrees compared to 127 degrees for the community group (p<0.001). The mean difference in the NSA of the fractured side compared to the normal hip was 2.5 degrees of valgus in the trauma group compared to 5 degrees of varus for the community group (p<0.001). There were 93 good reductions in the trauma group compared to 19 in the community group (p<0.001). There were no poor reductions in the trauma group and 49 poor reductions in the community group (p<0.001).

Fellowship trained traumatologists achieved significantly more accurate reductions and implant placement during cephalomedullary nailing of intertrochanteric hip fractures.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 52 - 52
1 Oct 2018
Parry J Langford J Koval K Haidukewych G
Full Access

Introduction

The vast majority of intertrochanteric fractures treated with cephalomedullary nails (CMN) will heal. Occasionally even though bony union occurs excessive lag screw sliding can cause persistent pain and soft tissue irritation and return to surgery for hardware removal. The purpose of this study was to evaluate if fracture stability, lag screw tip-apex distance (TAD), and quality of reduction have any impact excessive lag screw sliding and potential cutout.

Methods

As part of our level one trauma center's institutional hip fracture registry, a retrospective analysis identified 199 intertrochanteric fractures fixed with CMN between 2009 and 2015 with follow up to union or a minimum of three months. The mean follow-up was 22 months (3 to 94 months). Mean patient age was 75 years (50 to 97 years) and 72% were women. Postoperative radiographs were used to measure the TAD, quality of reduction, neck-shaft angle (NSA), and lateral lag screw prominence. Follow-up radiographs were reviewed to assess fracture union, translation, and progression of lateral lag screw prominence. Complications and reoperations were recorded.