The antidiabetic agent metformin inhibits fibrosis in various organs. This study aims to elucidate the effects of hyperglycaemia and metformin on knee joint capsule fibrosis in mice. Eight-week-old wild-type (WT) and type 2 diabetic (db/db) mice were divided into four groups without or with metformin treatment (WT met(-/+), Db met(-/+)). Mice received daily intraperitoneal administration of metformin and were killed at 12 and 14 weeks of age. Fibrosis morphology and its related genes and proteins were evaluated. Fibroblasts were extracted from the capsules of 14-week-old mice, and the expression of fibrosis-related genes in response to glucose and metformin was evaluated in vitro.Aims
Methods
Soft tissue balance is important for good clinical outcome and good stability after TKA. Ligament balancer is one of the devices to measure the soft tissue balance. The objective of this study is to clarify the effect of the difference in the rotational position of the TKA balancer on medial and lateral soft tissue balance. This study included with 50 knees of the 43 patients (6 males, 37 females) who had undergone TKA with ADLER GENUS system from March 2015 to January 2017. The mean age was 71.1±8.1 years. All patients were diagnosed with medial osteoarthritis of the knee. All implants was cruciate substituted type (CS type) and mobile bearing insert. We developed a new ligament balancer that could be fixed to the tibia with keel and insert trial could be rotated on the paddle. We measured the medial and lateral soft tissue balance during TKA with the new balancer. The A-P position of the balancer was fixed on tibia in parallel with the Akagi line (A-P axis 0 group) and 20 degrees internal rotation (IR group) and 20 degrees external rotation (ER group). Soft tissue balance was measured in extension and 90 degrees of knee flexion on each rotational position. The mean angle of valgus and varus in IR group, 0 group and ER group were 4.6±2.2 degrees varus, 1.9±1.6 degrees varus and 0.4±2.4 degrees varus respectively in extension, and 5.5±3.0 degrees varus, 2.1±2.2 degrees varus and 0.7±3.2 degrees varus respectively in 90 degrees of knee flexion. There were significant differences between three groups in extension (p<0.0001) and flexion (p<0.0001). In other words, when the balancer was fixed on tibia with internal rotation against the Akagi line, the soft tissue balance indicated medial tightness. Conversely, when the balancer was fixed on tibia with external rotation against the Akagi line, the soft tissue balance showed lateral tightness. The insert trial significantly rotated to opposite side against the position of balancer fixed.Materials and Methods
Results
Ultra-high molecular weight polyethylene (UHMWPE) is the sole polymeric material currently used for weight- bearing surfaces in total joint replacement. However, the wear of UHMWPE in knee and hip prostheses after total joint replacement is one of the major restriction factors on the longevity of these implants. In order to minimize the wear of UHMWPE and to improve the longevity of artificial joints, it is necessary to clarify the factors influencing the wear of UHMWPE. A number of studies have investigated the factors influencing the wear of UHMWPE acetabular cup liner in hip prosthesis. Most of these studies, however, have focused on the main articulating surfaces between the femoral head and the polyethylene liner. In a previous study (Cho Introduction
Materials and Methods
Ultra-high molecular weight polyethylene (UHMWPE) is the sole polymeric material currently used for weight- bearing surfaces in total joint replacement. However, the wear of UHMWPE in the human body after total joint replacement causes serious clinical and biomechanical reactions. Therefore, the wear phenomenon of UHMWPE is now recognized as one of the major factors restricting the longevity of artificial joints. In order to minimize the wear of UHMWPE and to improve the longevity of artificial joints, it is necessary to clarify the factors influencing the wear mechanism of UHMWPE. In a previous study (Cho Introduction
Materials and Methods
Ultra-high molecular weight polyethylene (UHMWPE) is the sole polymeric material currently used for weight- bearing surfaces in total joint replacement. However, the wear of UHMWPE and the polyethylene wear debris generated in the human body after total joint replacement cause serious clinical and biomechanical reactions. Therefore, the wear phenomenon of UHMWPE in total joint replacement is now recognized as one of the major factors restricting the longevity of these implants. In order to minimize the wear of UHMWPE and to improve the longevity of artificial joints, it is necessary to clarify the factors influencing the wear mechanism of UHMWPE. The wear and/or failure characteristics of 33 retrieved UHMWPE acetabular cup liners of hip prostheses were examined in this study. The retrieved liners had an average Introduction
Materials and Methods
Wear phenomenon of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee prostheses is one of the major restriction factors on the longevity of these implants. In retrieved hip prostheses with screw holes in the metal acetabular cup for fixation to the pelvis, the generation of cold flow into the screw holes is frequently observed on the backside of the UHMWPE acetabular cup liner. In most retrieved cases, the protruded areas of cold flow on the backside were located on the reverse side of the severely worn and deformed surface of the polyethylene liner. It would appear that the cold flow into screw holes contributes to increase of wear and damages of the polyethylene liner in hip prosthesis. In a previous study (Cho Introduction
Methods
The hip-knee-ankle (HKA) angle between the mechanical axis of the femur (FM) and the mechanical axis of the tibia (TM) is the standard parameter to assess the coronal alignment of the lower extremity. TM is the line between the center of the tibial spines notch (Point T) and the center of the tibial plafond. However, this theory is based on the premise that TM coincides the anatomical axis of the tibia (TA). Fig.1a shows typical varus knee with medial shift of the tibial articular surface. In this case, TM does not coincide TA. Fig. 2 demonstrates the error of HKA angle when Point T locates medial to TA. Fig.2a shows normal alignment. Fig.2b shows varus alignment. Fig. 2c shows the tibia with medial shift of the tibial articular surface. The tibia has 7 degrees varus articular inclination in Fig.2b and 2c. However, HKA angle is 0 degree in Fig.2c. HKA angle underestimates varus deformity in knees with medial shift of the tibial articular surface. However, the degree of medial shift of the tibial articular surface is obscure. In this study, detailed anatomical configuration of the proximal tibia was evaluated. The effect of the value of HKA angle on the coronal alignment in TKA was then discussed. This study consists of 117 knees. On the AP view radiograph of the tibia, three distance and two angle parameters were measured. Those were tibial articular surface width, distance between medial edge of the tibial articular surface and Point T, distance from TA to Point T. Angle between TM and TA, and the varus inclination angle of the tibial articular surface relative to the perpendicular line to TA.Introduction
Methods
The aim of this study was to evaluate the shape of patella relative to the femoral epicondylar axis and to find sex differences. Computed tomography (CT) images of 100 knees with tibiofemoral osteoarthritis in 100 patients were prospectively collected. All patients were diagnosed as varus-type osteoarthritis with no destructive patellar deformity. Fifty patients were male and 50 female. The average male age was 70.8±14.6 (mean ± SD) years and the average female age was 73.3±6.7 years. Forty nine knees were right and 51 knees were left. The average height of males was 162.6±7.4 cm and that of females 149.6±5.7 cm. Males were significantly taller than females. The CT scan was performed with 2mm-interval slices in the vertical plane to the long axis of femoral shaft. Every CT image was examined to determine the maximum distance between the medial and lateral femoral epicondyle (inter-epicondylar distance, IED) along the epicondylar axis. The maximum patellar width and thickness were also measured at the image which had these maximum distances, while patellar cartilage thickness in anteroposterior diameter was not measured in this study. For evaluating the patellar size, each measured value was divided by IED and calculated each ratio. The ratio of patellar width to patellar thickness was also calculated. All parameters were compared between males and females. Statistical software Statview ver.5.0 (SAS Institute Inc.) was used for all analyses with significance being set at the 5% level.Objective
Materials and methods
The objective of this study is to compare three dimensional (3D) postoperative motion between metal and ceramic bipolar hip hemiarthroplasty for femoral neck fracture. This study was conducted with forty cases (20 cases of metal bipolar hemiarthroplasty (4 males, 16 females), 20 cases of ceramic bipolar hemiarthroplasty (2 males, 18 females)) from November 2012 to November 2014. Average age was 80.8±7.5 years for the metal bipolar group and 79.3±10.5 years for the ceramic bipolar group. We obtained motion pictures from standing position to maximum abduction in flexion by fluoroscopy then analyzed by 2D–3D image matching method. The motion range of the “Shell angle”, “Stem neck angle” and the “Stem neck and shell angle” has been compared between the metal bipolar group and the ceramic bipolar group (Fig. 1). Metal bipolar showed greater variability of the Stem neck angle and Shell angle than ceramic bipolar. Six of the twenty cases reached unilateral oscillation angle of 37 degrees in metal bipolar. In other words, 30% of metal bipolar group revealed neck-shell impingement. No case reached oscillation angle of 58 degrees in ceramic bipolar group. There was no significant difference between the metal bipolar group and the ceramic bipolar group with respect to the difference of minimum and maximum angle of Stem neck angle (movement range of the stem neck) and Shell angle (movement range of the bipolar cup). On the other hand, difference of minimum and maximum angle of the Stem neck and shell angle (movement range of the inner head) was significantly greater in the metal bipolar group than the ceramic bipolar group. Movement, range of bipolar shell was significantly greater than that of inner head in both groups (Table 1).Materials and Methods
Results
Differences in the sizes of femoral and tibial components between females and males, between osteoarthritis (OA) and rheumatoid arthritis (RA), and between measured bone resection and the gap control technique during TKA were assessed. 500 PS-TKAswith the Stryker NRG system in 408 cases were assessed. There were 83 male knees and 417 female knees, and 472 OA knees and 28 RA knees. This study was performed in Japan, and almost all OA knees had varus deformities. In each case, the sizes of the femoral and tibial components were measured on radiographs. The measured sizes represented those of the measured bone resection. TKA was performed by the gap control technique using a tensor/balancer with 30 inch-pounds expansion strength, and the sizes of the femoral and tibial components (used size) were recorded.Purpose:
Method:
Following total knee arthroplasty (TKA), some patients show patella baja. It is possible that patella baja after posterior stabilized (PS)-type TKA causes the patellar clunk syndrome and limitation of flexion. The purpose of this study was to examine patellar height before and after PS-type TKA and identify the factors related to the change in patellar height. Lateral X-ray films were taken at 90 degrees flexion before and after TKA using fluoroscopy in 87 patients (95 knees) (Fig. 1a, b). The components and surgical technique for TKA were Scorpio NRG (Stryker) and the modified gap control technique, respectively. The Insall-Salvati ratio (ISR) and the Labelle-Laurin method (LL) were measured as parameters of patellar height (Fig. 1c, d). Posterior condylar offset (PCO) (Fig. 1e), the distance from the anterior femoral line to the tibial tuberosity (TA), and the distance from the tibial tuberosity to the posterior condyle of the femur [TP; {TA-F (the length of the femoral condyle)}] (Fig. 1f) were examined as parameters that could be associated with the change in patellar height. All parameters were divided by patellar length to compensate for the expansion rate in each photograph. The mean LL/P, PCO/P, TA/P, and TP/P before TKA were set at 100%.Introduction
Methods
The purpose of this study is to inspect balance of the pelvis in the acetabular operation of total hip arthroplasty (THA) using direct anterior approach (DAA), and it is to examine precision of the acetabular socket setting. We performed THA using DAA to 104 patients (114 hips) joints from August 2006 to April 2009 and identified for seventy five patients (eighty four hips) that imaging of the postoperative CT was possible. The orientation of acetabular sockets were performed using an alignment guide which assumed an operating table an axis from August 2006 to September 2008 (A group), and using an alignment guide which assumed a pelvis an axis from October 2008 to May 2009(B group). A group were thirty eight patients (forty four hips), and B group were twenty eight (thirty). There were two men and thirty six women in A group, and one man and twenty seven women in B group. The average age of both groups was 66 years old. The objective angle of the acetabular socket was performed as angle guide of abduction of 45° and anteversion of 20°. The orientation of the acetabular socket converted the angle of postoperative CT into radiographic angle, and measured it. For sixteen hips in B group, both angle guide was used, and there were measured a difference of two angle guide in the acetabular operation as movement of the pelvis. The examination item assumed it the mean values of angle for the acetabular socket in both groups, precision to set up the acetabular socket to planned orientation within ±5 °and a mean difference of two angle guides of sixteen hips in B group.Purpose
Materials and Methods
Total Hip Arthroplaty (THA) using posterior approach(PA) that resect muscle have done from September, 2005 to August, 2006, but, for the purpose of a lower invasive surgery, we changed to THA using direct anterior approach(DAA) that preserve muscle from September, 2006. The purpose of this study was to compare the inflammation degree and clinical results of MIS-THA using PA with that of MIS-THA using DAA. From September 2005 to May 2008,73 hips in 69 patients were treated with consecutive primary cement-less MIS THA. The breakdown of the patients was DAA, 51 hips, and PA, 22. The average age at operation was 66 years and 58 years. The average followup after primary THA was 1.5 years and 2.8 years. The sex ratio (M/F) was DAA 2/44, and PL 6/15. For the inflammation degree, CRP at the seventh day and 14 day after surgery of DAA was significantly lower than those of PA (p<
0.01). WBC of the seventh day of DAA was significantly lower than that of PA.CPK on DAA at the first was significantly lower than that of PL (p<
0.01), and CPK of PL took time for a long time to decrease to the level before the operation compared with DAA. For clinical results, there were no significant difference operative time, blood loss volume and complication in DAA and PA. No significant differences in the HHS at the final follow up were observed between DAA and PA. In the radiographic assessment, there was no significant difference in neutral position of stem of DAA(46hips) and PA (18hips), and there was no significant difference in abduction angle of socket in DAA(average 45°) and PA (47°). The day of SLR possibility was significantly earlier DAA (average 4 day) than PA (7). No significant differences in hospital stay were observed between DAA (average 21 days) and PA (26). In the current study, there was thought that DAA was lower inflammation degree than PA, because normalization of CRP after surgery in DAA was significantly early in comparison with PA, and CPK of the first day after surgery was significantly lower in DAA than in PA. In the clinical assessment, the day of SLR possibility only was significantly earlier in DAA than in PA. This may imply muscle recovery of DAA is more rapid than that of PA. In the future, DAA will help to the further early rehabilitation and the early hospital discharge.