Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 13 - 13
2 May 2024
Wijesekera M East J Chan CD Hadfield J As-Sultany M Kassam A Petheram T Jones HW Palan J Jain S
Full Access

This large UK multicentre study evaluates clinical outcomes and identifies factors associated with local complication following PFR for non-oncological conditions.

132 patients across four UK centres underwent PFR from 01/08/2004-28/03/2023 with median follow-up of 1.9 (Q10.5-Q34.2) years. 75 (56.8%) patients were female and the mean age was 74.0 (SD 11.7) years. 103 (78%) patients had Charleston Comorbidity Index ≥3. ASA class was III or IV in 66.6%. Indications were infected revision (39, 29.5%), periprosthetic fracture (36, 27.3%), acute trauma (30, 22.7%), aseptic revision (17, 12.9%), failed trauma (nine, 6.8%) and complex primary arthroplasty (one, 0.8%). The primary outcome was the local complication rate. Secondary outcomes were systemic complications, reoperation and mortality rates. Comparisons were made with t-tests and Chi2 tests to investigate patient and surgical factors associated with local complication. Statistical significance was p<0.05.

There were 37(28.0%) local complications. These were 18 (13.6%) dislocations, eight (6.1%) prosthetic joint infections, four (3.0%) haematomas, three (2.3%) superficial infections, one (0.8%) wound dehiscence, one (0.8%) sciatic nerve palsy and one (0.8%) femoral perforation. Dislocation mostly occurred in conventional articulations (12, 9.1%) followed by dual-mobility cups (three, 2.3%), constrained cups (two, 1.5%) and hemiarthroplasty (one, 0.8%). Median time to local complication was 30 (Q14-Q3 133) days. Seven (5.3%) patients developed a systemic complication. Thirty-three (25.0%) patients underwent reoperation. Thirty-day and one-year mortality rates were 3.8% and 12.1%, respectively. Longer surgical waiting times (7.9 \[SD 16.9) versus 2.6 \[SD 4.4\] days, p<0.001) and longer operating times (212.5 \[SD 71.8\] versus 189.4 \[SD 59.3\] mins, p=0.0450) were associated with local complication.

Due to its high complication rate, PFR should be a salvage option when performed for non-oncological indications. Conventional articulations should be avoided. PFR should be delivered in a timely manner and ideally as dual-consultant cases to reduce operating time.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 21 - 21
7 Jun 2023
Nandra R Fishley W Whitehouse S Carluke I Kramer D Partington P Reed M Evans J Panteli M Charity J Wilson M Howell J Hubble M Petheram T Kassam A
Full Access

In metal-on-metal (MoM) hip replacements or resurfacings, mechanical induced corrosion can lead to a local inflammatory response, pseudo tumours and elevated serum metal ions, requiring revision surgery.

The size and diametral clearance of Anatomic (ADM) and Modular (MDM) Dual Mobility bearings matches that of certain MOM components. Presenting the opportunity for revision with exchange of the metal head for ADM/MDM bearings without removal of the acetabular component if it is well-fixed and appropriately positioned.

Between 2012 and 2020, across two centres, 94 patients underwent revision of a MoM hip replacement or resurfacing. The mean age was 65.5 (33–87) years. In 53 patients (56.4%), the acetabular component was retained, and dual mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). DM was only considered where the acetabular component was satisfactorily positioned and well-integrated into bone, with no surface damage. Patients underwent clinical and radiographic follow-up to at least one-year (mean 42.4 (12–96) months).

One (1.1%) patient died before one-year, for reasons unrelated to the surgery. In the DM group, two (3.8%) patients underwent further surgery; one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (12.2%) underwent further procedures; two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operative time (68.4 v 101.5 mins, p<0.001), postoperative drop in haemoglobin (16.6 v 27.8 g/L, p<0.001), and length of stay (1.8 v 2.4 days, p<0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p<0.001 both Cobalt and Chromium) although there was no difference between groups for this reduction (p=0.674 Cobalt; p=0.186 Chromium).

In selected patients with MoM hip arthroplasty, where the acetabular component is well-fixed, in a satisfactory position and there is no surface damage, the metal head can be exchanged for ADM/MDM bearings with retention of the acetabular prosthesis. Presenting significant benefits through a less invasive procedure, and a low risk of complications, including dislocation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 23 - 23
7 Jun 2023
Coveney E Hutton C Patel N Whitehouse S Howell J Wilson M Hubble M Kassam A
Full Access

Venous thromboembolism (VTE) is a preventable cause of morbidity and mortality in patients undergoing elective hip arthroplasty surgery. The balance of post-operative VTE prophylaxis and risk of post-operative haemorrhage remains at the forefront of surgeon's mind. The National Institute for Clinical Excellence (NICE) has altered their prophylaxis guidance in the setting of total hip arthroplasty (THA). The aim of this study was to present the VTE incidence in 8,890 patients who underwent total hip arthroplasty between January 1997 and March 2018 with Aspirin as the primary agent for pharmacological thromboprophylaxis.

Analysis of prospective data collection from consecutive patients undergoing THA was performed with the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) occurring within 6 months of the index operation as the primary outcome measure. 90-day all-cause mortality of this cohort of patients was also analysed.

8890 patients were reviewed. This included 7235 primary, 224 complex primary and 1431 revision cases. The incidence of DVT was 0.64% after elective THA and the incidence of PE was 0.54%. There was no difference in the incidence between primary and revision cases. The 90-day all-cause mortality was 0.88%. Cardiovascular and respiratory disease were the main causes of death following surgery. Only 0.03% of deaths (n= 3) within 90 days of index surgery were due to VTE.

Our results support the use of aspirin as an effective form of prophylaxis against VTE following THA. It is not associated with an increased incidence in symptomatic DVT, PE or death compared to other published studies. The fact that it is inexpensive, readily available, requires no monitoring and does not pose an increased risk of bleeding are other attractive advantages of using aspirin for VTE prophylaxis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 38 - 38
7 Jun 2023
Ewels R Kassam A Evans J
Full Access

Electronic Health Records (EHRs) have benefits for hospitals and uptake in the UK is increasing. The National Joint Registry (NJR) monitors implant and surgeon performance and relies on accuracy of data. NJR data are used for identification of potential outliers for both mortality and revision; analyses are adjusted for age, sex, and American Society of Anaesthesiologists score (ASA) and cases with some indications are excluded from analyses. In October 2020, the Royal Devon University Hospitals NHS Foundation Trust “went live” on an EHR, almost eradicating paper from the Trust. This included stopping use of paper NJR forms by creating a bespoke electronic template. We sought to identify discrepancies between operation notes and data input to the NJR in variables that may influence potential outlier analyses.

Data input to the NJR from 15/10/2020 to 18/10/2022 for hip procedures were provided by NEC Software Solutions. NJR data were compared to those recorded on operation notes.

There were 1067 hip procedures recorded in the NJR (946 primary THRs). Of the primary THRs, discrepancies in indication between NJR and operation note were identified in 139 (15%) cases. Common discrepancies included cases being recorded as osteoarthritis where the true indication was acute trauma (n=63), avascular necrosis (n=14), metastatic cancer/malignancy (n=6) and 21 cases with no recorded indication. We identified 88 cases where the ASA recorded in the NJR differed from the anaesthetic chart. Other inaccuracies were identified including 23 cases missing type of procedure (e.g., primary or revision) and one where revision surgery had been recorded as primary.

We identified at least 83 cases that should have been excluded from NJR mortality analyses but were not. Given the low incidence of mortality following primary THR, these cases (with increased risk of death) have the potential to incorrectly identify the hospital as a potential outlier. Discrepancies in ASA may also impact on both revision and mortality outlier calculations. We urge caution to hospitals in the implementation of EHRs and advise regular audit of data sent to the NJR.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 12 - 12
1 Apr 2022
Walton T Huntley D Whitehouse S Ross A Kassam A
Full Access

The aim of this study was to systemically review the evidence for the use of intra-operative cell salvage (ICS) among patients undergoing revision hip arthroplasty, and synthesis the available data to quantify any associated reduction in allogeneic blood transfusion.

An electronic database search of MEDLINE (PubMed), EMBASE, Scopus and the Cochrane Library was completed from the date of inception to 9th February 2021, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were (i) adult patients >18 years, (ii) ICS utilised in one study group, (iii) revision hip arthroplasty performed. Exclusion criteria were (i) pre-donation of red blood cells, (ii) mixed reporting without dedicated subgroup analysis for revision hip arthroplasty. Screening for eligibility, and quality assessment of included studies, was performed independently by two authors (TW and DH), and any disputes settled by third author (AK).

Of the 187 records identified, 11 studies were included in the qualitative analysis, and 5 studies suitable for quantitative meta-analysis. Across the included studies there were 1856 participants, with a mean age of 63.86 years and a male: female ratio of 0.90. Quality assessment demonstrated low or medium risk of bias only. For revision hip arthroplasty patients receiving ICS, 37.07% required ABT with a mean transfusion of 1.92 units or 385ml per patient. For patients treated without ICS, 64.58% required ABT with a mean transfusion of 4.02 units or 803ml per patient. This difference achieved statistical significance (p < 0.05).

This study has demonstrated a significant reduction in the need for allogenic blood transfusion associated with intra-operative cell salvage use among patients undergoing revision hip arthroplasty. This study therefore supports the routine use of ICS in this patient group. However, a major limitation is the lack of clinical outcomes reported by the available studies. Further research is required to determine whether this effect is associated with sub-groups of revision arthroplasty procedure, and whether ICS impacts clinical outcomes such as length of stay, rehabilitation progress and mortality.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 34 - 34
1 Apr 2022
Gowda S Whitehouse S Morton R Panteli M Charity J Wilson M Timperley J Hubble M Howell J Kassam A
Full Access

The MAKO Robotic arm is a haptic robotic system that can be used to optimise performance during total hip arthroplasty (THA). We present the outcome of the first 40 robotic cases performed in an NHS foundation trust along with the technique of performing robotic THA in our unit.

Forty consecutive patients undergoing robotic THA (rTHA) were compared to a case matched group of patients undergoing manual THA (m-THA). 2:1 blinded case matching was performed for age, sex, implants used (Trident uncemented socket and cemented Exeter stem, Stryker Mahwah, NJ, US) and surgeon grade. Comparisons were made for radiological positioning of implants, including leg length assessment, and patient reported functional outcome (PROMS). Pre- and post-operative radiographs were independently analysed by 2 authors.

All patients underwent THA for a primary diagnosis of osteoarthritis. No significant difference between groups was identified for post-operative leg length discrepancy (LLD) although pre-operatively a significantly higher LLD was highlighted on the MAKO group, likely due to patient selection. Significantly lower post-operative socket version was identified in the MAKO cohort although no difference in post-operative cup inclination was noted. However, there was significantly larger variance in post-op LLD (p=0.024), cup version (p=0.004) and inclination (p=0.05) between groups indicating r-THA was significantly less variable (Levene's test for homogeneity of variance). There was no significant difference in the number of cases outside of Lewinnek's ‘safe’ zone for inclination (p=0.469), however, there were significantly more cases outside Lewinnek's ‘safe’ zone for version (12.5% vs 40.3%, p=0.002) in the m-THA group.

We report the commencement of performance of MAKO robotic THA in an NHS institution. No problems with surgery were reported during our learning curve. Robotic THA cases had less variability in terms of implant positioning suggesting that the MAKO robot allows more accurate, less variable implant positioning with fewer outliers. Longer term follow-up of more cases is needed to identify whether this improved implant positioning has an effect on outcomes, but the initial results seem promising.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 25 - 25
1 Apr 2022
Evans J Salar O Whitehouse S Kassam A Howell J Wilson M Timperley J Sayers A Whitehouse M Wilton T Hubble M
Full Access

The Exeter V40 femoral stem is the most implanted stem in the NJR for primary THA. In 2004, the 44/00/125 stem was released for use in “cement-in-cement” revision cases. It has however been used ‘off-label’ as a primary stem when, for example, patient anatomy requires a smaller stem with a 44mm offset. We aimed to investigate survival of this stem in comparison to others in the range when used in primary THAs recorded in the NJR.

Analyses were performed using a dataset based on that used for the 2020 NJR annual report. Our exposure was the stem; the outcome was all-cause construct revision. Crude analyses were performed using Kaplan-Meier and adjusted using Cox models. The 44/00/125 stem was directly compared to other stems in the Exeter range.

We analysed 330,732 primary THAs using the Exeter V40 stem comprising 34.5% of the 958,869 THAs with complete information from the start of the NJR to 31 December 2018. The 44/00/125 stem was implanted in 2,158 primary THAs with 67.5% in female patients and a mean age of 67.8. The 10-year revision estimate for the 44/00/125 stem was 4.9% (95%CI 3.6, 6.8) and in constructs using an Exeter V40 stem was 2.8% (95%CI 2.7, 2.8). Controlling for age, sex and ASA demonstrated an increased overall hazard of revision for constructs using the 44/00/125 stem compared to constructs using other Exeter V40 femoral stems (HR 1.8 (95%CI 1.4, 2.3)).

Although the revision estimate is within the NICE 10-year benchmark, survivorship of constructs using the 44/00/125 stem appears to be lower than the rest of the Exeter V40 range. Attempts to control for age, sex and ASA will not take into account confounding by indication i.e. patients with more complex anatomy who may have a higher risk of revision. Surgeons and patients should be reassured by this but should be aware of the observed increased revision estimate and use the stem according to its indications.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 29 - 29
1 Aug 2021
Fishley W Selvaratnam V Carluke I Partington P Reed M Kramer D Wilson M Hubble M Howell J Timperley A Whitehouse S Kassam A Petheram T
Full Access

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision necessitate removal of all bone cement from the femur. In our two institutions, we have been using a cement-in-cement technique, leaving the distal femoral cement in selected cases for septic hip revision surgery.

Between February 2010 and September 2019, 89 patients with prosthetic hip infection underwent first or single stage procedures leaving the distal femoral cement in situ and performing a cement-in-cement revision. The mean patient age was 72.0 years (24–92). The median time from the last arthroplasty procedure was 29.0 months (1–294).

81 patients underwent revision using a cemented Exeter stem, 7 patients received an articulating spacer, and one patient underwent excision arthroplasty with the distal cement left in situ. Patients received clinical and radiographic follow-up with a mean of 42.8 months (range 11.0–120.1 months). Oxford hip scores were collected from each institution's existing databases.

9 patients (10.1%) died within one year of surgery. No deaths were directly related to joint infection or the surgery. One patient was lost to follow up before one year.

Of the remainder, 7 patients (8.9%) required further procedures for infection and were therefore considered to be treatment failures. 6 patients (7.6%) underwent planned second stage procedures with no recurrence of infection. 7 patients (8.9%) had further surgery for non-infective reasons. The Kaplan-Meier estimate of infection free survival at one year was 93.7% (95% CI 88.4 to 99.0%).

No patients underwent revision for stem loosening. Oxford hip scores were available at over one year postoperatively for 51 patients with a mean score of 30.6, and a mean gain of 11.9.

In our combined cohort of patients, cement-in-cement revision had an infection eradication rate of 91.1%. Patient selection is crucial, and the procedure can only be performed when there is a well-fixed cement mantle. However, when strict criteria are followed, this technique offers potential significant benefits to surgeons performing this challenging surgery, and more importantly the patients undergoing them.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 22 - 22
1 May 2019
Takada R Whitehouse S Hubble M Wilson M Howell J Timperley A Kassam A
Full Access

Introduction

Varus alignment of the femoral component in total hip arthroplasty (THA) is thought to be a risk factor for implant loosening and early revision surgery. The purpose of this study was to evaluate whether the Exeter stem tolerates varus alignment and assess if this theoretical malalignment has an influence on clinical outcomes.

Methods

A total of 4126 consecutive THAs were reviewed for patients between 2006 and 2012 to allow for a minimum five-year follow-up. To determine the effects of the stem alignment on results, the hips were classified into 3 groups on the basis of stem alignment in initial postoperative anteroposterior radiographs. The alignment of the stem was defined as neutral, valgus (≥ 3° of lateral deviation), or varus (≥ 3° of medial deviation). The primary outcome was all cause revision with patient related outcomes assessed with Oxford hip score pre and post-operatively.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 24 - 24
1 May 2019
Kassam A Whitehouse S Wilson M Hubble M Timperley A Howell J
Full Access

Introduction

Rationing of orthopaedic services is increasingly being used by Care Commissioning Groups (CCG) within the United Kingdom to restrict the numbers of patients being referred for Total Hip Arthroplasty (THA). In Devon, only patients with an Oxford Hip Score (OHS) less than 20 are referred on for specialist Orthopaedic Review. The aim of this study was to look at long term outcomes after THA to see if this rationing has any rational base to justify its use

Methods

Consecutive patients undergoing THA in Exeter between 1996 and 2012 had OHS' collected prospectively pre-operatively and a minimum of 4 years post-operatively. These scores were analysed looking for trends in patient related outcome scores.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 16 - 16
1 May 2018
Kassam A Batten T Keenan J Williams M Yarlagadda R
Full Access

Introduction

Patient related outcome measures (PROMS) are now routinely undertaken in patients undergoing hip arthroplasty. These are in the form of the Oxford Hip Score (OHS) and EQ5D questionnaires pre-operation and at 6 months' post operation. MYMOPS is a patient specific outcome measure that allows patients to list their individualised symptoms and activities that are limited and is used is other medical specialities but not currently within orthopaedic surgery. The aim of this study was to validate the MYMOPS questionnaire for use in hip arthroplasty by comparing it to the OHS.

Patients/Materials & Methods

At a single centre, 50 patients were recruited to our prospective trial after ethical approval. A MYMOPS questionnaire and an OHS was filled in pre-operation and then at 6 months post-operatively. 6 patients filled in either form incorrectly and were excluded. The remaining 44 included 30 females and 14 males with an average age of 68.5 (range 35–90).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 22 - 22
1 Mar 2014
Kassam A Davis J
Full Access

Foot and ankle surgery is a rapidly evolving specialty. As the number and complexity of cases increases, the number of complaints, litigation and pay-outs has also risen. We aim to assess any learning points discerned from NHS litigation data to allow us help improve patient care.

All claims made to the NHS Litigation Authority between 2007 and 2012 relating to foot and ankle problems were obtained under the Freedom of Information Act. These were reviewed, coded and split into subgroups to allow analysis.

There were 232 successful litigation cases between 2007 and 2012. The total amount paid out was almost £18.5 million (range £112 to £1.6 million). A significant number of successful cases were due to patients not having full, informed consent.

A large amount of money is spent in the NHS is spent on litigation. The amount of litigation and payout in foot and ankle surgery compares favourably with hip and knee surgery.

Lack of informed consent is an easily reversible problem that should be decreasing but is actually on the rise. In our trust, we advocate the use of consent clinics which provide a robust and patient-centred approach to informed consent in foot and ankle surgery.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 11 - 11
1 Apr 2013
Godden A Kassam A Cove R
Full Access

Literature has suggested that obese (BMI >30) and morbidly obese (BMI > 35) patients should not be offered surgery as a day case due to increases in complication and readmission rates. At Torbay hospital, patients are routinely offered day case surgery, in a specialist day case unit, regardless of BMI. This is done with minimal complications and enables a higher throughput of patients and at least 75% of surgical procedures to be performed as a day case, as per NHS guidelines.

We present 12 year data of day case knee arthroscopy surgery performed at Torbay hospital. Over 12 years, 3421 knee arthroscopies were performed. 649 were performed on obese patients and 222 on morbidly obese patients. No anaesthetic complications were observed in any of the obese patient groups and readmissions rates (up to 28 days) were 0.8% in the morbidly obese group and 0.9% in the Obese group, compared to 0.9% for patients with BMI <30.

Our data shows that day case surgery can be performed on all patients regardless of BMI and patient obesity. We believe that other units should offer surgery to obese and morbidly obese patients to allow increased efficiency and achievement of NHS day case guidelines.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 23 - 23
1 Apr 2013
Kassam A Blake S
Full Access

Treatment for an infected Total Hip replacement (THR) remains controversial with two stage revision surgery traditionally recommended. We describe a series of one stage revisions performed in a District General Hospital to help inform other surgeons and help treatment decisions.

8 patients with a bacteriologically proven infection in their hip underwent single stage revision THR. Cemented Exeter prostheses were used with additional antibiotics added to the cement mixture prior to implantation.

Follow-up ranged from 6 to 36 months (average 16.6 months) and there were no re-infections. No radiological changes consistent with re-infection were noted throughout patient follow-up. One patient suffered a periprosthetic fracture (thought to be secondary to myeloma) 3 months post-surgery and underwent further revision surgery. Post-operative antibiotics were given for a minimum of 6 weeks with 2 patients having a 3 month supply after Microbiology advice.

Single stage revision THR surgery is a viable and useful option for treatment of infected THR's. Re-infection rates are low. Avoiding the traditional second stage surgery is beneficial to both patients and the NHS trust in terms of health and cost outcomes. We will continue to undertake single stage revisions in this trust and advocate its use by other surgeons.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 4 - 4
1 Apr 2013
Kassam A Griffiths S Higgins G
Full Access

Recent NICE guidelines have suggested abandoning the Thompson hemiarthroplasty (TH) in favour of a ‘proven prosthesis’ such as the Exeter Trauma Stem (ETS). This is controversial because of significant cost implications and limited research assessing outcomes of the ETS. The aim of this study was to assess the treatment of intracapsular neck of femur fractures with the TH.

Between 2002 and 2006 (minimum 5 year follow-up), 431 cemented TH's were performed. Death rate at 1 year and 5 years were 26.0% and 67.7% respectively. Dislocation (1.4%) and infection (0.2%) rates were low and revision rate was 1.2%. Comparison was made to Bipolar hemiarthroplasties over the same period (total 194). These had lower rates of dislocation (0.5%) and infection (0.5%) with a significantly higher (3.6%) revision rate.

We feel that the TH remains the current gold standard treatment for intracapsular fractures, in appropriate patients, due to low complication and revision rates. Modern implants may provide better function or longevity, but there is no evidence in the literature to support abandoning the TH. Surgeons should assess patients and decide on its use, despite NICE guidelines, as it remains a cost effective treatment method, particularly for older, less mobile and cognitively impaired patients.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 11 - 11
1 Apr 2013
Mandalia V Kassam A Schranz P
Full Access

Introduction

Anatomical reconstruction of the Anterior Cruciate Ligament (ACL) reconstruction has been shown to be desirable and improve patient outcome. The posterior border of the anterior horn of the lateral meniscus (AHLM) is an easily identifiable arthroscopic landmark, which could guide anatomic tibial tunnel position in the sagital plane. The aim of the study was to establish the relationship between the posterior border of AHLM and the centre of the ACL foot print to facilitate anatomical tibial tunnel placement.

Materials/Methods

We analysed 100 knee MRI scans where there was no ACL or lateral meniscal injury. We measured the distance between the posterior border of the AHLM and the midpoint of the tibial ACL footprint in the sagital plane. The measurements were repeated 2 weeks later for intra-observer reliability.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 31 - 31
1 Feb 2013
Kassam A Ainsworth B Hawken R Ramesh R Conboy V
Full Access

Patients using a neutral rotation brace post proximal humerus fracture fixation have improved functional outcome and external rotation of the shoulder compared to patients using a standard polysling.

Patients who have proximal humerus fracture fixation with extramedullary plates and screws have a risk of reduced range of movement especially external rotation. Gerber et al showed that the average external rotation after fixation of proximal humeral fractures was 39 degrees in their patient cohort compared to a normal range of 80–100 degrees. This can lead to reduced function and poor patient related outcomes. Geiger et al showed that in a cohort of 28 patients, poor functional outcome was noted in 39.3% with an average Constant-Murley Score of 57.9.

Current practice is to utilise a polysling holding the shoulder in internal rotation post-shoulder fixation. Patients usually wear the sling for up to 6 weeks. We believe that this increases the risk of adhesion formation with the shoulder in internal rotation in the shoulder joint. Therefore this can cause loss of external rotation in the shoulder joint. We believe that holding the shoulder in a neutral alignment, with a neutral rotation brace post-fixation, will enable an increased rate of external rotation post-operatively thus improving external rotation and functional outcome

There is currently no literature comparing the different slings used post-operatively and we believe that this study would be the first of its kind. It would have a substantial change in the way clinicians manage proximal humeral fractures and will potentially reduce the numbers of re-operations to divide adhesions or perform capsular releases. Secondary benefits include a potential earlier return to full function and work and improved patient satisfaction.

Study proposal: Prospective Randomised Controlled Trial of the neutral rotation brace compared to the standard, currently used, polysling post proximal humerus fracture fixation. No blinding of either participants or clinicians. Three surgeons utilising similar fixation techniques via the deltopectoral approach and using Philos plate fixation (Synthes Ltd.). Standardised post-operative rehabilitation protocol for all patients.

Follow up: clinical review and postal outcomes for 1 year

Primary outcomes: Post operative functional outcome scores (Oxford, DASH, EQL) obtained at 6 weeks, 9 weeks, 3 months and 1 year). These will be compared to scores taken pre-operatively.

Secondary outcomes: Clinical review at 6 weeks, 3 months and 1 year with range of movement measurements. Radiographs also taken at 6 weeks and 3 months to assess union. Patient questionnaire at 1 year (with outcome scores) assessing patient return to work, complications and patient satisfaction

Inclusion criteria: Proximal humeral fractures requiring operative intervention with extramedullary plate fixation (i.e. fractures displaced by 1cm and/or angulated by 45 degrees or more). Age>18.

Exclusion Criteria: Patients having intra-operative findings of complete Pectoralis major rupture or if operative exposure requires complete Pectoralis major tenotomy. (These patients need to be held in internal rotation with a standard polysling to allow healing of the Pectoralis major tendon).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 11 - 11
1 Feb 2013
Kassam A Evans J Guyver P Hubble M
Full Access

Femoral neck stress fractures (FNSF) are uncommon, representing 3.5% to 8% of all stress fractures in military recruits. The majority of displaced FNSF undergo operative fixation and are at risk of avascular necrosis (AVN) and non union with a 40–100% medical discharge rate. We aimed to review the incidence and outcome of displaced FNSF in Royal Marine Recruits.

Retrospective review identified 6 Royal Marine recruits, aged 17 to 25, who had suffered a displaced FNSF over a 6 and a half year period. Incidence was 0.93 per 1000 recruits.

Patients were treated urgently by operative fixation with a 2 hole dynamic hip screw device, in 3 cases supplemented with an anti-rotation screw. There were no cases of AVN, no surgical complications and no further procedures were required. All united with a mean time to union of 11 months. 50% had a union time greater than 1 year. 2 completed training, 2 are still in rehabilitation and 2 (33%) were discharged before completion of training.

These fractures are slow to unite compared to other fractures at this site or stress fractures elsewhere. With urgent surgical intervention and stable fixation all however went onto successful union with time and all returned to rehabilitation or training with minimal complications. Awareness of the length of time to union has been invaluable in guiding treatment and rehabilitation. It can help avoid the risks of unnecessary secondary interventions for delay to union.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 234 - 234
1 Sep 2012
Kassam A Dieppe P Toms A
Full Access

Purpose

Great expense is accumulated in investigation and management, often with poor outcome, of a patient with a painful TKR. We aim to produce guidelines for their investigation and careful, successful management.

Method

We studied 42 cases of patients with a painful TKR. Costs were calculated of appointments, serological and radiological investigations for these patients and an average cost of investigating a patient was obtained. We also calculated costs of various forms of management, both surgical and non-surgical and correlated these with patient outcomes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 20 - 20
1 Mar 2012
Kassam A Toms A Hopwood B Stroud R
Full Access

Purpose

To calculate the cost of investigation of a painful Total Knee Replacement (TKR) to the hospital trust and Primary Care Trust (PCT).

Method

28 patients, over a year period, with painful Total Knee replacements were collected. Costs were calculated only of those patients who had an improvement in their symptoms such that they no longer had a painful TKR. The numbers of appointments, number of serological and radiological investigations were calculated along with any further investigations such as aspirations and arthroscopies. Costs were calculated from hospital records and charges to the PCT. An average cost per patient of investigations was calculated