Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 466 - 466
1 Sep 2012
Ditsios K Kapoukranidou D Boutsiadis A Chatzisotiriou A Albani M Christodoulou A
Full Access

Purpose of this study is to create an experimental model of electrophysologic evaluation of the supraspinatus muscle on rats, after traumatic rupture of its tendon.

The population of this study consisted of 10 male Sprague Dawley rats weighting 300–400g. Under general anaesthesia we proceeded with traumatic rupture of the supraspinatus tendon and exposure of the muscle. The scapula was immobilized, and the supraspinatus tendon was attached to a force transducer using a 3–0 silk thread. A dissection was performed in order to identify the suprascapular nerve, which was then stimulated with a silver electrode. Stimulations were produced by a stimulator (Digitimer Stimulator DS9A) and were controlled by a programmer (Digitimer D4030). Fiber length was adjusted until a single stimulus pulse elicited maximum force during a twitch under isometric conditions. Rectangular pulses of 0.5 ms duration were applied to elicit twitch contractions. During the recordings, muscles were rinsed with Krebs solution of approximately 37 8C (pH 7.2–7.4) and aerated with a mixture of 95% O2 and 5% CO2. The output from the transducer was amplified and recorded on a digital interface (CED).

The following parameters were measured at room temperature (20–21 8C): single twitch tension; time to peak; half relaxation time; tetanic tensions at 10, 20, 40, 80 and 100 Hz; and fatigue index, which was evaluated using a protocol of low frequency (40 Hz) tetanic contraction, during 250 ms in a cycle of 1 s, for a total time of 180 s. The fatigue index value was then calculated by the formula [fatigue index=(initial tetanic tension − end tetanic tension) ∗ 100/(initial tetanic tension)]. In the end, the transducer was calibrated with standard weights and tensions were converted to grams.

The mean single twitch was 8.2, the time to peak 0.034 msec and the half relaxation time 0.028 msec. The strength of titanic muscle contractures was 5.7 msec at 10Hz and 17.7 at 100Hz. Finally, the fatigue index was calculated at 48.4.

We believe that electrophysiologic evaluation of the supraspinatus muscle in rats will help us understanding the pathology of muscle atrophy after rotator cuff tears and possibly the functional restoration after cuff repair


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 356 - 356
1 Jul 2011
Ditsios K Kapoukranidou D Boutsiadis A Chatzisotiriou A Alpani M Christodoulou A
Full Access

Purpose of this study is to create an experimental model on rats for EMG evaluation of the supraspinatus muscle after traumatic rupture of its tendon.

The population of this study consisted of 5 male rats of 300–400g. Under general anaesthesia we proceeded with traumatic rupture of the supraspinatus tendon and exposure of the muscle. The electrode of a stimulator was placed under suprascapular nerve and the supraspinatus tendon was sutured on a transducer for digital record of the produced signal. Initially we found the resting length and the electric intensity for higher muscle contracture. The parameters that were evaluated after single contracture (single twitch) were strength, time to peak, half relaxation time. Furthermore, it was evaluated the strength of tetanic contractures at 10,20,40,80,100 Hz (Stimulation for 350msec each time).Finally it was evaluated the muscle fatigue with stimulation at 40Hz for 250msec and total duration of 3 minutes. Fatigue index was calculated according to the decrease of titanic muscle contracture (Initial value-Final Value/Initial Value x 100)

Our results are presented in mean ± sd. The single twitch was 8.2(5.1),the time to peak 0.034(0.02) msec, the half relaxation time 0.028(0.008)msec. The strength of titanic muscle contractures was 5.7msec at 10Hz and 17.7 at 100Hz. Finally the fatigue index was calculated at 48.4.

We believe that EMG evaluation of the supraspinatus muscle in rats will help us understanding the pathology of muscle atrophy after rotator cuff tears and possibly the functional restoration after cuff repair.